Match the complete marking
Include 21000-16-10-06-065-04-02 and the visible revision or assembly identity in your enquiry. Keep the full reference on the quotation. -
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 21000-16-10-06-065-04-02 with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 21000-16-10-06-065-04-02
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:21000-16-10-06-065-04-02
-
Weight:1.05 kg
-
Tariff Code:8537101190
-
Assembly family:21000 proximity probe housing
-
Housing construction:aluminum body
-
Probe selection:3300 XL 8 mm probe
-
Probe lead:1.0 m
-
Standoff option:C06; dimension to be confirmed
-
Penetration option:6.5 in probe penetration
-
C plus D selection:C06 dimension plus 6.5 in penetration; confirm total reach
-
Conduit fittings:one 3/4-14 NPT plug
-
Mounting option:3/4-14 NPT mounting thread
-
Sleeve material:304 stainless steel
-
Probe mounting:reverse mount
Information
- Bently Nevada 21000-16-10-06-065-04-02. This aluminum body housing gives external access to a reverse-mounted proximity probe at a machine casing.
Selected 8 mm probe rating: -51 to +177 °C operating and storage
Pressure-seal caution: Exposure below -34 °C can shorten seal life
Compliance: RoHS Directive 2011/65/EU
C06 is the standoff selection on the complete marking; confirm its actual dimension on the offered assembly and machine drawing. Option 065 specifies 6.5 in probe penetration. Establish the final probe gap from the machine drawing and matched transducer procedure. A 304 stainless steel sleeve carries the reverse-mounted probe through the casing. The probe lead must exceed the sleeve length, and sleeves longer than 304 mm (12 in) need additional support to limit vibration of the unsupported sleeve.
Option 04 identifies one 3/4-14 NPT plug; option 02 identifies 3/4-14 NPT mounting thread. The conduit entry, sealing arrangement and case interface must match these selected pieces. The all-metal assembly uses a screw-on dome cover, conduit ports, O-rings and a thread seal around the probe sleeve. The 21000 body is aluminum; the 24701 body is 303 stainless steel. The housing family meets API 670 requirements for externally mounted proximity probe housings; any hazardous-area approval depends on the approved complete configuration.
-
Bently Nevada 21000-16-10-06-065-04-02 technical reference
Original manufacturer excerpt - PDF, 4 pages. The 141600 order matrix supports the 21000 family and confirmed options; verify the C06 standoff dimension on the offered assembly. -
Bently Nevada 21000-16-10-06-065-04-02 installation guide
Prepared by Apter Power - PDF, 5 pages. Installation checks, fitting and lead routing, commissioning and verification.
Compatibility scope: The assembly uses a 1.0 m probe lead and the selected 3/4-14 NPT mounting thread. The C06 standoff dimension must be confirmed before the complete reach can be established. Match the probe, extension cable and Proximitor to the installed transducer system; the housing alone does not define system calibration.
-
Shaft radial vibration
Place the probe at a documented bearing-casing location where its tip faces a suitable shaft target. A matched 3300 XL 8 mm channel can then follow relative shaft motion at that measurement plane. -
Shaft position
Use a suitable target and monitor configuration where static shaft position or axial displacement is part of the approved machine measurement plan. The available target travel and probe gap determine whether this mounting location is suitable. -
External probe access
The housing makes the reverse-mounted probe and field connection accessible from outside the casing. This arrangement supports maintenance of the sensing point while retaining the planned machine-case penetration. -
Casing and conduit interface
The aluminum body housing uses the selected 3/4-14 NPT mounting thread. The C06 standoff dimension must be confirmed before the complete reach can be established. The selected fittings establish the conduit entry arrangement.
Apply the site lockout and machine-safe procedure before opening the probe housing. Preserve the existing probe-gap and cable-routing records for restoration.
Verify the 3/4-14 NPT mounting thread against the machined casing opening. Avoid forcing a different thread or changing the selected standoff and penetration.
Confirm the C06 standoff dimension and 6.5 in penetration from the approved assembly drawing before setting sleeve length or probe gap. Support any sleeve longer than 304 mm (12 in) to limit unsupported-sleeve vibration.
Inspect the dome cover, O-rings, thread seal, cable seal grip and conduit entries after assembly. Close unused ports and apply the approved casing pressure-boundary inspection.
Keep the 1.0 m probe lead protected and match its connector, extension cable and Proximitor to the installed 3300 XL 8 mm channel. Confirm the total system length before interpreting the signal.
Set the probe gap against the target under the approved site procedure. Verify the restored gap indication and channel response before releasing the machine.
Alternative Names
Technical notes
Installation relationship: Confirm the C06 standoff dimension, then add the 6.5 in penetration to establish the selected reach and installed position.
Protection: Approval of a hazardous-area installation depends on the complete housing and transducer arrangement; do not infer it from a fitting alone.
Technical reference: Bently Nevada 21000, 24701, and 164818 Proximity Probe Housing Assemblies, 141600 Rev. AC.
FAQ View All FAQ
-
What housing construction does 21000-16-10-06-065-04-02 use?The 21000 assembly uses an aluminum body housing; match its body and sleeve to the installed machine environment.
-
Which probe option is selected on 21000-16-10-06-065-04-02?Code 16 selects 3300 XL 8 mm probe; the probe is a component of the housing assembly.
-
How long is the probe lead specified for 21000-16-10-06-065-04-02?Code 10 selects 1.0 m of probe cable. Check the remaining transducer-system length with the installed extension cable and Proximitor sensor.
-
How does 21000-16-10-06-065-04-02 establish its standoff position?C06 is the selected standoff code. Confirm its physical length on the offered assembly and installation drawing before setting the probe position.
-
What penetration is encoded in 21000-16-10-06-065-04-02?Option 065 denotes 6.5 in probe penetration. Add the confirmed C06 standoff length to determine the total C plus D reach.
-
Which conduit pieces are associated with 21000-16-10-06-065-04-02?Option 04 selects one 3/4-14 NPT plug. Confirm that the offered hardware corresponds to the complete assembly.
-
What mounting interface is selected for 21000-16-10-06-065-04-02?Code 02 specifies 3/4-14 NPT mounting thread; do not substitute a different thread or sleeve arrangement.
-
When does the sleeve of 21000-16-10-06-065-04-02 need additional support?The manufacturer calls for support when C plus D exceeds 12 in. Confirm the C06 dimension, calculate the total reach with D065, and assess sleeve support against the machine layout.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.