Technical specifications for 1900/65A-01-01-03-00-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:1900/65A-01-01-03-00-00
-
Weight:1.3 kg
-
Tariff Code:8537101190
-
Supply configuration:110-220 V AC, 50-60 Hz through an external supply
-
Display:Attached; no separate cable
-
Mounting / enclosure:fiberglass NEMA 4X/IP66 weatherproof housing with a window door
-
Monitor-side operating current:0.35 A typical; 1.0 A maximum
-
Monitor-side operating power:8.5 W typical; 14 W maximum
-
Transducer inputs:4; acceleration, velocity, radial vibration, thrust, position or speed
-
Temperature inputs:4; E/J/K/T thermocouples or 2-/3-wire RTDs
-
Relay outputs:6 SPDT; programmable logic
-
Maximum relay operands:50 per relay
-
Recorder outputs:4 x 4-20 mA; configurable channel/variable
-
Maximum recorder loop resistance:600 ohms
-
Recorder update interval:100 ms
-
Configuration retention:Non-volatile memory
-
Configuration interface:Built-in Ethernet
-
Modbus:Not included
Information
- Bently Nevada 1900/65A-01-01-03-00-00 combines local measurement visibility with a windowed protective enclosure, allowing condition-monitoring values to be reviewed without relying on a networked operator station.
Local access: Attached display; PC configuration through Ethernet
Protective outputs: Six programmable relays and four 4-20 mA recorders
Six SPDT relays can combine OK, Alert and Danger status through programmable expressions with up to 50 operands per relay. Latching and energized-state selections are independent. AND ignores bypassed channels while True AND includes them, which makes the exact voting expression significant during channel maintenance. Four independently assigned 4-20 mA outputs update every 100 ms and support up to 600 ohms loop resistance under the applicable loop-supply conditions.
The selected AC option uses an external 110-220 V AC, 50-60 Hz supply. A fiberglass NEMA 4X/IP66 housing with a window door accommodates local observation; cable entries and closure must preserve the enclosure installation. The final 00 selection omits Modbus. Ethernet remains available for configuration transfer, while the four recorder outputs provide independently assigned analog variables to receiving equipment.
1900/65A-01-01-03-00-00 Official Technical Reference Excerpt
1900/65A General Purpose Equipment Monitor, 173401 Rev. AC: preserved manufacturer technical information applicable to this configuration. PDF · 9 pages.1900/65A-01-01-03-00-00 Installation & Verification Guide
Apter Power field guide covering display access, external AC power and enclosure preparation, relay tests and analog recorder checks. PDF · 5 pages.
Application scope: Suitable general-purpose machines may combine vibration, temperature and discrete protection. The examples describe integration roles, not preconfigured alarm settings or a universal machine-protection design.
Local condition display
Read configured channel values at the machine-monitoring position using the attached display.Combined thermal and vibration monitoring
Pair compatible bearing-temperature circuits with the selected vibration measurements.Programmable protection contacts
Use reviewed relay expressions to combine warning, danger and channel-health states.Analog trend recording
Send selected variables to recording or control inputs using four independently assigned current loops.
Check the external AC supply and maintain window-door housing closure and cable-entry sealing.
Record transducer type, sensitivity, wiring and temperature-sensor selection.
Use the site-approved maintenance state before altering relays or alarm settings.
Match each recorder variable and full scale to the receiving input.
Test normal, alarm, Not OK, bypass and reset behavior against the approved logic.
Use Ethernet for configuration; this order code does not include Modbus process communication.
Alternative Names
Technical notes
Power boundary: 110-220 V AC, 50-60 Hz through an external supply. Monitor-side DC demand is not the AC mains input-current rating.
Display selection: The attached display is included without a separate display cable. Remote-display accessories are not implied.
Communication selection: The final 00 selection omits Modbus. Ethernet remains available for configuration transfer, while the four recorder outputs provide independently assigned analog variables to receiving equipment.
FAQ View All FAQ
-
Can 1900/65A-01-01-03-00-00 be connected directly to an arbitrary AC terminal?The selected AC option is 110-220 V AC at 50-60 Hz through an external power supply. Use that supply and its approved wiring; do not apply mains voltage to monitor-side DC terminals.
-
What does the window-door enclosure add to 1900/65A-01-01-03-00-00?The CC03 option specifies a fiberglass NEMA 4X/IP66 weatherproof housing with a window door. The completed installation must preserve closure, seals and suitable cable entries.
-
Which controls are available at the attached display of 1900/65A-01-01-03-00-00?The display provides channel information and minor setting access. Use PC configuration software for the complete channel, relay and recorder setup; an attached display is not a full substitute for that workflow.
-
Must a recorder on 1900/65A-01-01-03-00-00 follow the input with the same channel number?No. Each of the four recorders can be assigned a selected channel variable. Trace the assignment and full-scale mapping before interpreting the receiver value.
-
How much loop resistance can 1900/65A-01-01-03-00-00 support on its recorder circuits?The specified maximum is 600 ohms under the applicable 18-36 V DC recorder-loop supply conditions. Include receiver and cable resistance in the loop assessment.
-
Why can a relay remain latched after a measurement returns to normal on 1900/65A-01-01-03-00-00?A relay configured for latching requires a reset after its initiating condition clears. Verify the logic state and reset path; a reset cannot correct an active sensor fault.
-
Are the six contacts of 1900/65A-01-01-03-00-00 all driven by one common alarm rule?No. Each SPDT relay has its own programmable expression, with up to 50 operands. Its energized-state and latching choices must also match the intended circuit.
-
Can 1900/65A-01-01-03-00-00 send event records to a DCS over Modbus?This final-00 build omits the Modbus option. Its configuration Ethernet connection and attached display do not establish Modbus event reporting.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.