Match the complete marking
Match the complete B&R X20BB22 marking, hardware revision and selected configuration to the installed position. Check base function and serial connection against the installed configuration.
-
Check the offered item before ordering
Request label and connection photographs. Have your maintenance team compare the offered X20BB22 with the installed equipment and applicable B&R instructions.
Technical specifications for X20BB22
-
Manufacturer:B&R
-
Product Category:PLC Systems
-
Spare Part Number:X20BB22
-
Weight:0.04 kg
-
Tariff Code:8537101190
-
Base function:X20 Compact CPU and compact CPU supply module
-
Serial connection:1 x RS232
-
Nominal I/O supply:24 V DC
-
Permissible contact load:10 A
-
Bus power consumption:0.32 W
-
RS232 isolation:Bus not isolated from RS232
-
Protection degree:IP20
-
Horizontal operating temperature:-25 to 60°C
-
Vertical operating temperature:-25 to 50°C
-
Altitude derating above 2000 m:0.5°C per 100 m
-
Storage temperature:-40 to 85°C
-
Operating humidity:5 to 95%, non-condensing
Information
- B&R X20BB22 provides the mechanical and electrical base of a compact X20 controller assembly, including its supply routing and serial-interface connection.
Serial connection: 1 x RS232
Nominal I/O supply: 24 V DC
Nominal I/O supply voltage is 24 V DC, with a permissible contact load of 10 A. Bus power consumption is 0.32 W. The bus is not electrically isolated from the RS232 connection, so serial-device reference potentials require consideration.
Horizontal installation permits -25 to 60°C operation; vertical installation permits -25 to 50°C. Above 2000 m, reduce the ambient temperature limit by 0.5°C per additional 100 m. The IP20 base requires a suitable protected installation environment.
X20BB22 Official Technical Excerpt
Original B&R technical material applicable to X20BB22, covering function, interfaces and operating limits. PDF · 2 pages.X20BB22 Installation & Verification Guide
Apter Power field guide for the selected connection, configuration and functional tests. PDF · 5 pages.
Application scope: The technical values apply to this model in the specified installation and configuration. The examples below address the stated product function.
Compact controller assembly
Provide the base for an X20 Compact CPU and its matching compact supply module.Serial equipment integration
Bring the integrated RS232 connection into the controller assembly with appropriate potential-reference checks.Backplane replacement
Restore a damaged base while preserving the installed CPU, supply module and locking-plate arrangement.Elevated-site installation
Apply orientation and altitude temperature limits to a protected X20 controller installation.
Record the CPU and compact supply module mounted on the base.
Check the left and right X20 locking plates before dismantling the assembly.
Remove power through the approved cabinet isolation procedure before moving modules.
Compare the connected supply loading with the 10 A permissible contact load.
The bus is not isolated from RS232.
Examine the RS232 connection and mating cable for bent contacts or mechanical strain.
Alternative Names
Technical notes
Retain both end locking plates: Check the left and right X20 locking plates before dismantling the assembly. Restore the mechanical restraint and module engagement so the controller and supply module remain properly seated on the base.
Review serial reference potentials: The bus is not isolated from RS232. Check the reference potential of the connected serial equipment and preserve the established grounding arrangement before reconnecting the cable to the replacement assembly.
Verify the restored controller station: Check module seating, supply status and the configured RS232 exchange after controlled energization. Retain the CPU and supply identities, mounting orientation and any altitude correction with the final service record.
FAQ View All FAQ
-
Does X20BB22 contain the controller CPU itself?No. It is the base for an X20 Compact CPU and compact CPU power supply module; the processor and supply modules are separate functional components.
-
Which serial connection is provided by X20BB22?The base provides the connection for the compact CPU's integrated RS232 interface.
-
Is the RS232 connection on X20BB22 isolated from the bus?No. The bus is not isolated from RS232, so connected-device reference potentials must be considered.
-
How much current may pass through the supply contacts of X20BB22?The permissible contact load is 10 A at the nominal 24 V DC I/O supply. The associated power and protection arrangement must respect this limit.
-
Why does mounting orientation affect the temperature limit of X20BB22?Its permitted ambient range is -25 to 60°C horizontally and -25 to 50°C vertically; the selected orientation determines the applicable thermal limit.
-
What altitude correction applies to X20BB22 above 2000 m?Reduce the permissible ambient temperature by 0.5°C for each additional 100 m above 2000 m.
-
Are the end locking plates included with X20BB22?Yes. Left and right X20 locking plates X20AC0SL1 and X20AC0SR1 are included with the base.
-
Can X20BB22 be exposed to condensing humidity?No. The specified operating humidity is 5 to 95%, non-condensing, and the protection degree is IP20.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.