Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 7CP476.60-1
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 7CP476.60-1

  • Manufacturer:
    B&R
  • Product Category:
    PLC Systems
  • Spare Part Number:
    7CP476.60-1
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Austria
  • SRAM:
    750 kB
  • FlashPROM:
    1.5 MB
  • Supply:
    24 V DC
  • Power consumption:
    12.5 W
  • Interfaces:
    RS232; CAN
  • CAN:
    Electrically isolated; network-capable
  • Expansion:
    4 screw-in module slots

Information

Overview Manuals Common Applications Product Precautions
B&R 7CP476.60-1 is system 2003 cpu. It executes System 2003 control applications and provides isolated CAN plus serial communication and four screw-in expansion positions.
  • Provides 750 kB SRAM
  • Provides 1.5 MB FlashPROM
  • Integrates isolated network-capable CAN
  • Accepts four screw-in interface modules

7CP476.60-1 operates with System 2003 rack and I/O, 24 V DC supply, approved screw-in modules, Automation Studio application backup.

Engineered applications include System 2003 machine controller, CAN device integration, Serial equipment control, Legacy CPU replacement.

Important Notice: Back up application and retained data, identify all screw-in modules, record CAN node settings and verify I/O before production restart.

Apter Power 7CP476.60-1 Manuals and Guides

Apter Power 7CP476.60-1 Product and System Technical Reference PDFApter Power 7CP476.60-1 Installation and Commissioning Workbook PDF

The first document presents model-specific engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.

System 2003 machine controller

Runs installed machine logic.

CAN device integration

Coordinates CAN-connected equipment.

Serial equipment control

Maintains serial device communication.

Legacy CPU replacement

Restores a legacy controller from the approved program.

Read the applicable B&R instructions before work. Verify 7CP476.60-1 and the installed B&R System 2003 PLC configuration.
1

Verify the full 7CP476.60-1 marking and its assigned B&R System 2003 PLC position before work.

2

Place the connected machine or process in the approved maintenance state.

3

Isolate the applicable supply and plc execution plus rs232, can and system 2003 i/o data field energy before disconnecting conductors.

4

Record connector, conductor, address and software identities before removal.

5

Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.

6

Confirm the installed System 2003 rack and I/O and 24 V DC supply against the approved project.

7

Restore power in a controlled sequence and review device, network and host diagnostics.

8

Prove the intended system 2003 machine controller function and retain the final test result.

Technical notes

Back up application and retained data, identify all screw-in modules, record CAN node settings and verify I/O before production restart.

FAQ View All FAQ

  • Which installed system position is intended for 7CP476.60-1?
    Install 7CP476.60-1 only in the documented B&R System 2003 PLC position and verify the complete catalog marking against the approved hardware list.
  • What signal or controlled function does 7CP476.60-1 handle?
    Its documented duty is plc execution plus rs232, can and system 2003 i/o data; the official record lists flashprom as 1.5 MB.
  • Which companion hardware must be matched to 7CP476.60-1?
    Match 7CP476.60-1 with System 2003 rack and I/O and 24 V DC supply, including the documented carrier, cable and project identity.
  • Which electrical value must be verified before wiring 7CP476.60-1?
    Verify power consumption: 12.5 W. Do not transfer limits from another catalog number.
  • How should the configuration be preserved when replacing 7CP476.60-1?
    Record the as-found position, conductors, addressing and software revision, then restore only the approved B&R System 2003 PLC configuration.
  • Which isolation and handling checks apply to 7CP476.60-1?
    Isolate the documented supply and field energy, use ESD controls and protect the keyed connectors before handling 7CP476.60-1.
  • How should an engineer commission 7CP476.60-1?
    Power up in a controlled sequence, review device and host diagnostics, then prove the intended system 2003 machine controller function.
  • Can 7CP476.60-1 replace a visually similar module without further checks?
    No automatic substitution is assumed; compare the full catalog number, interfaces, sram and approved system revision.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.