RPBA-01 3ABD64606859

PROFIBUS DP Adapter Module
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

ABB RPBA-01 3ABD64606859 is an optional PROFIBUS DP adapter module for ABB drives. It connects the installed drive as a slave to a PROFIBUS DP or DP-V1 control network.

Ask our team:

Get a quick price for: RPBA-01 3ABD64606859
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for RPBA-01 3ABD64606859

Technical specifications for RPBA-01 3ABD64606859

  • Manufacturer:
    ABB
  • Product Category:
    General Automation
  • Spare Part Number:
    3ABD64606859
  • Estimated shipping dimensions:
    6.6x3.5x9.4cm
  • Weight:
    0.06 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Sweden
  • Type designation:
    RPBA-01
  • Supported fieldbus:
    PROFIBUS DP, PROFIBUS DP-V1
  • Network role:
    Slave
  • PROFIBUS connector:
    9-pin female D-sub
  • Drive connection:
    34-pin parallel bus connector
  • Station address range:
    0 to 126
  • Hardware address range:
    00 to 99
  • Supported PPO types:
    1 to 6
  • Maximum cyclic input data:
    28 bytes
  • Maximum cyclic output data:
    28 bytes
  • Maximum cyclic I/O total:
    56 bytes
  • Maximum acyclic I/O:
    240 bytes input / 240 bytes output
  • Current consumption:
    350 mA maximum at 5 V
  • Degree of protection:
    IP20
  • Supported baud rates:
    9.6 kbit/s to 12 Mbit/s

Information

Information

Overview Manuals Common Applications Product Precautions
RPBA-01 3ABD64606859 provides the PROFIBUS DP slave interface between a documented ABB drive and its control network.
  • Links an ABB drive to a PROFIBUS DP or DP-V1 master
  • Transfers drive control words, references, status and actual values
  • Supports cyclic PPO communication and acyclic DP-V1 services
  • Automatically detects the configured PROFIBUS transmission rate

The adapter is mounted in the approved drive option slot and communicates with a compatible PROFIBUS DP master through the 9-pin D-sub port. Engineering work covers the selected GSD file, node address, PPO telegram, parameter mapping, cable shield, segment termination and controlled drive diagnostics.

Important Notice: Confirm RPBA-01, 3ABD64606859, the installed ABB drive and option slot, adapter hardware version, 9-pin PROFIBUS connector, 34-pin drive connector, node address, PPO type, GSD, bus wiring and termination, shield grounding, drive firmware and parameters, and controlled communication and run-test results before commissioning.

Apter Power RPBA-01 3ABD64606859 Manuals and Guides

The first document is an Apter Power model-specific engineering reference. The second opens the exact manufacturer manual or datasheet for this product.

PROFIBUS-controlled motor drives
Connects a documented ABB drive to the plant PROFIBUS master for command and status exchange.
Drive reference and actual-value transfer
Carries the approved speed or torque reference and corresponding process feedback.
Drive parameter service over DP-V1
Supports authorized acyclic parameter access from a compatible engineering or control station.
Existing PROFIBUS drive replacement
Preserves node addressing, PPO mapping and bus-segment behavior during controlled drive service.
Read the applicable ABB installation instructions before work. Verify RPBA-01 3ABD64606859, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm RPBA-01 and manufacturer item number 3ABD64606859 before work.
2
Isolate the ABB drive and wait at least five minutes for DC-link discharge.
3
Use ESD controls and record the installed option slot, hardware revision and connector orientation.
4
Record the node address, selected GSD, PPO type and process-data mapping before removal.
5
Inspect the D-sub connector, 34-pin drive connector, shield and protective-ground arrangement.
6
Confirm termination is active only at the first and last station of the PROFIBUS segment.
7
Restore the approved drive parameters and network configuration before controlled energization.
8
Verify master recognition, cyclic I/O, acyclic access, drive diagnostics and a controlled run test.

Alternative Names

Alternative Names

RPBA-01 3ABD64606859

Technical notes

Technical notes

Fit RPBA-01 only in the documented drive option slot and reproduce the recorded PROFIBUS address, PPO type, baud-rate detection, GSD and process-data mapping. De-energize the drive, wait for DC-link discharge, preserve bus termination and shield grounding, then verify cyclic and acyclic communication before drive enable.

FAQS

  • Which ABB drives can use RPBA-01 3ABD64606859?
    Use it only where the installed ABB drive documentation provides the compatible option slot and RPBA-01 support. Confirm the drive type, control-board execution, firmware and option-slot assignment before installation.
  • What network role does RPBA-01 3ABD64606859 perform?
    It operates as a PROFIBUS DP slave and exchanges control, reference, status, actual-value and parameter data with a compatible PROFIBUS DP master.
  • How is the station address set for RPBA-01 3ABD64606859?
    Record the approved node assignment and reproduce it using the module address controls or the supported configuration method. The documented station address range is 0 to 126, while the rotary-switch range is 00 to 99.
  • Which GSD file should be used for RPBA-01 3ABD64606859?
    Match the project to the communication mode documented for the installation: ABB_0812.GSD for DP-V0 or ABB10812.GSD for DP-V1, then verify the selected PPO and I/O mapping.
  • How should PROFIBUS termination be checked for RPBA-01 3ABD64606859?
    Termination must be active at the first and last station of the segment only. Confirm the connector termination switch, module power and shield grounding before enabling communications.
  • What should be recorded before replacing RPBA-01 3ABD64606859?
    Record the drive and option slot, node address, GSD, PPO type, process-data map, cable routing, termination state, shield connection, hardware version and diagnostics.
  • How is RPBA-01 3ABD64606859 commissioned after replacement?
    Restore the approved drive and master configuration, confirm master recognition, compare cyclic input and output words, verify authorized acyclic access and review both drive and network diagnostics.
  • Can RPBA-01 3ABD64606859 be moved to another PROFIBUS segment without verification?
    No. Revalidate node uniqueness, baud-rate compatibility, cable length, termination, shield grounding, GSD, PPO mapping and the receiving control-system database before service.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.