Technical specifications for RPBA-01 3ABD64606859

  • Manufacturer:
    ABB
  • Product Category:
    General Automation
  • Spare Part Number:
    3ABD64606859
  • Estimated shipping dimensions:
    6.6x3.5x9.4cm
  • Weight:
    0.06 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Sweden
  • Type designation:
    RPBA-01
  • Supported fieldbus:
    PROFIBUS DP, PROFIBUS DP-V1
  • Network role:
    Slave
  • PROFIBUS connector:
    9-pin female D-sub
  • Drive connection:
    34-pin parallel bus connector
  • Station address range:
    0 to 126
  • Hardware address range:
    00 to 99
  • Supported PPO types:
    1 to 6
  • Maximum cyclic input data:
    28 bytes
  • Maximum cyclic output data:
    28 bytes
  • Maximum cyclic I/O total:
    56 bytes
  • Maximum acyclic I/O:
    240 bytes input / 240 bytes output
  • Current consumption:
    350 mA maximum at 5 V
  • Degree of protection:
    IP20
  • Supported baud rates:
    9.6 kbit/s to 12 Mbit/s

Information

Overview Manuals Common Applications Product Precautions
RPBA-01 3ABD64606859 provides the PROFIBUS DP slave interface between a documented ABB drive and its control network.
  • Links an ABB drive to a PROFIBUS DP or DP-V1 master
  • Transfers drive control words, references, status and actual values
  • Supports cyclic PPO communication and acyclic DP-V1 services
  • Automatically detects the configured PROFIBUS transmission rate

The adapter is mounted in the approved drive option slot and communicates with a compatible PROFIBUS DP master through the 9-pin D-sub port. Engineering work covers the selected GSD file, node address, PPO telegram, parameter mapping, cable shield, segment termination and controlled drive diagnostics.

Important Notice: Confirm RPBA-01, 3ABD64606859, the installed ABB drive and option slot, adapter hardware version, 9-pin PROFIBUS connector, 34-pin drive connector, node address, PPO type, GSD, bus wiring and termination, shield grounding, drive firmware and parameters, and controlled communication and run-test results before commissioning.

Apter Power RPBA-01 3ABD64606859 Manuals and Guides

The first document is an Apter Power model-specific engineering reference. The second opens the exact manufacturer manual or datasheet for this product.

PROFIBUS-controlled motor drives
Connects a documented ABB drive to the plant PROFIBUS master for command and status exchange.
Drive reference and actual-value transfer
Carries the approved speed or torque reference and corresponding process feedback.
Drive parameter service over DP-V1
Supports authorized acyclic parameter access from a compatible engineering or control station.
Existing PROFIBUS drive replacement
Preserves node addressing, PPO mapping and bus-segment behavior during controlled drive service.
Read the applicable ABB installation instructions before work. Verify RPBA-01 3ABD64606859, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm RPBA-01 and manufacturer item number 3ABD64606859 before work.
2
Isolate the ABB drive and wait at least five minutes for DC-link discharge.
3
Use ESD controls and record the installed option slot, hardware revision and connector orientation.
4
Record the node address, selected GSD, PPO type and process-data mapping before removal.
5
Inspect the D-sub connector, 34-pin drive connector, shield and protective-ground arrangement.
6
Confirm termination is active only at the first and last station of the PROFIBUS segment.
7
Restore the approved drive parameters and network configuration before controlled energization.
8
Verify master recognition, cyclic I/O, acyclic access, drive diagnostics and a controlled run test.

Alternative Names

RPBA-01 3ABD64606859

Technical notes

Fit RPBA-01 only in the documented drive option slot and reproduce the recorded PROFIBUS address, PPO type, baud-rate detection, GSD and process-data mapping. De-energize the drive, wait for DC-link discharge, preserve bus termination and shield grounding, then verify cyclic and acyclic communication before drive enable.

FAQ View All FAQ

  • Which ABB drives can use RPBA-01 3ABD64606859?
    Use it only where the installed ABB drive documentation provides the compatible option slot and RPBA-01 support. Confirm the drive type, control-board execution, firmware and option-slot assignment before installation.
  • What network role does RPBA-01 3ABD64606859 perform?
    It operates as a PROFIBUS DP slave and exchanges control, reference, status, actual-value and parameter data with a compatible PROFIBUS DP master.
  • How is the station address set for RPBA-01 3ABD64606859?
    Record the approved node assignment and reproduce it using the module address controls or the supported configuration method. The documented station address range is 0 to 126, while the rotary-switch range is 00 to 99.
  • Which GSD file should be used for RPBA-01 3ABD64606859?
    Match the project to the communication mode documented for the installation: ABB_0812.GSD for DP-V0 or ABB10812.GSD for DP-V1, then verify the selected PPO and I/O mapping.
  • How should PROFIBUS termination be checked for RPBA-01 3ABD64606859?
    Termination must be active at the first and last station of the segment only. Confirm the connector termination switch, module power and shield grounding before enabling communications.
  • What should be recorded before replacing RPBA-01 3ABD64606859?
    Record the drive and option slot, node address, GSD, PPO type, process-data map, cable routing, termination state, shield connection, hardware version and diagnostics.
  • How is RPBA-01 3ABD64606859 commissioned after replacement?
    Restore the approved drive and master configuration, confirm master recognition, compare cyclic input and output words, verify authorized acyclic access and review both drive and network diagnostics.
  • Can RPBA-01 3ABD64606859 be moved to another PROFIBUS segment without verification?
    No. Revalidate node uniqueness, baud-rate compatibility, cable length, termination, shield grounding, GSD, PPO mapping and the receiving control-system database before service.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.