Product Describe:
ABB RL01, also marked RL 01 or RL-01, is a legacy Hartmann & Braun Contronic module. Exact catalog variants include the 0776038 series and must be matched to the installed board marking.
ABB RL01, also marked RL 01 or RL-01, is a legacy Hartmann & Braun Contronic module. Exact catalog variants include the 0776038 series and must be matched to the installed board marking.
Contronic system role: Provides the documented legacy module role within a matching H&B Contronic rack.
Alias-controlled identity: Recognizes RL01, RL 01 and RL-01 as marking forms while retaining the part variant.
Revision boundary: Requires the installed 0776038-series suffix to be confirmed.
Legacy support: Supports controlled maintenance of an installed Contronic system.
Use RL01, RL 01 and the complete installed 0776038-series marking together. Record the rack, slot and all connected circuits before replacement.
Important Notice: Confirm the complete ABB RL01 RL 01 identity and controlled configuration before commissioning.
The first document presents model-specific technical and system data. The second provides a separate installation, connection, commissioning and acceptance workflow.
H&B Contronic maintenance
Maintains the matching legacy module position in a documented Contronic rack.
Exact-board replacement
Replaces an RL01 only after the 0776038-series variant is confirmed.
Installed-system preservation
Keeps the recorded rack, slot and field relationships intact.
Legacy inventory identification
Uses all marking aliases to match the physical board and maintenance record.
Read the applicable ABB instructions before work. Verify ABB RL01 RL 01 and the installed system configuration before commissioning.
1
Verify ABB RL01 RL 01 and the complete 0776038-series marking.
2
Record the rack, slot, connectors and connected circuits before work.
3
Place the controlled equipment in the approved maintenance state.
4
Use ESD controls and inspect the card edge and backplane.
5
Do not treat 0776038B, 0776038E and 0776038F as interchangeable without approval.
6
Do not infer another module function from a similar RL or RLM name.
7
Restore all connections exactly as recorded.
8
Complete the documented system and affected-circuit tests before release.
Technical notes
Use RL01, RL 01 and the complete installed 0776038-series marking together. Record the rack, slot and all connected circuits before replacement.