Match the complete marking
Send the complete 170M5388/PC72UD13C250T 3AUA0000090404 marking, revision labels, current-unit photographs and installed position.
-
Check the offered item before ordering
Compare the offered 170M5388/PC72UD13C250T 3AUA0000090404 interfaces, ratings and included items with the approved system record before ordering.
Technical specifications for 3AUA0000090404 170M5388 PC72UD13C250T
-
Manufacturer:ABB
-
Product Category:DCS Systems
-
Spare Part Number:170M5388/PC72UD13C250T 3AUA0000090404
-
Weight:0.74 kg
-
Tariff Code:8537101190
-
Complete product reference:170M5388/PC72UD13C250T 3AUA0000090404
-
Product type:ABRU-02 DC-Chopper High-Speed Fuse
-
System platform:ABB ACS800-67LC, ACS800-77LC and ACS800-87LC converter systems
-
ABB MRP code:3AUA0000090404
-
Bussmann type:170M5388
-
Supplied marking:PC72UD13C250T
-
ABB manual cross-reference:Mersen PC72UD13C250TF
-
Protected assembly:ABRU-02 DC chopper
-
Documented quantity:2 fuses per ABRU-02
-
Protection class:High-speed semiconductor fuse
-
System context:ACS800 liquid-cooled wind-turbine converters
-
Selection boundary:Rating, melting curve, body and terminal execution
-
Shipping size (est.):7.5cm x 6cm x 7.5cm
-
Shipping weight:0.74 kg
-
Country of Origin:Sweden
Information
- ABB 170M5388/PC72UD13C250T 3AUA0000090404 is a abru-02 dc-chopper high-speed fuse documented for ABB ACS800-67LC, ACS800-77LC and ACS800-87LC converter systems.
Cross-manufacturer identity: ABB records Bussmann 170M5388 and Mersen PC72UD13C250TF for the same ABRU-02 fuse position.
Matched replacement pair: Quantity and complete electrical/mechanical execution are checked before changing either fuse.
The supplied marking PC72UD13C250T differs by one final character from the ABB manual cross-reference, so the body label and complete MRP code 3AUA0000090404 must be photographed and matched before approval.
Replacement requires the converter isolation and DC-link discharge procedure, examination of the failed-current path and comparison of both fuse positions. A fuse should not be energized until the chopper and associated resistor circuit are cleared for service.
170M5388/PC72UD13C250T 3AUA0000090404 Technical Reference
ABB ABRU-0x DC Choppers and Resistors Hardware Manual. Exact-model identity and the applicable system evidence are retained without distributor advertising.170M5388/PC72UD13C250T 3AUA0000090404 Installation & Verification Guide
Product-specific field guide for identity capture, controlled exchange, commissioning evidence and handover.
Application scope: Use 170M5388/PC72UD13C250T 3AUA0000090404 only where the product identity, ratings, companion hardware and approved system documentation agree.
ABRU-02 DC-chopper protection
Provide the documented high-speed fuse pair for the chopper power path.ACS800 wind-converter maintenance
Retain converter type, chopper identity and fuse arrangement.Semiconductor fault containment
Coordinate fuse replacement with inspection of power semiconductors and resistor circuits.Cross-reference verification
Reconcile Bussmann, Mersen and ABB MRP markings before order approval.
Prove the converter is safe before opening the chopper path.
Reconcile ABB MRP, Bussmann and Mersen identities.
Check the complete ABRU-02 fuse pair.
Inspect chopper semiconductor and resistor circuits.
Verify curve, body, terminals and indicator.
Retain diagnostics and DC-link behavior.
Alternative Names
Technical notes
Exact identity: 170M5388/PC72UD13C250T 3AUA0000090404
Documented function: ABRU-02 DC-Chopper High-Speed Fuse
Technical evidence: ABB ABRU-0x DC Choppers and Resistors Hardware Manual
Evidence boundary: Only the documented ABB ACS800-67LC, ACS800-77LC and ACS800-87LC converter systems relationship and stated exact-model values are applied
Commissioning record: Retain installed markings, configuration and functional proof
FAQ View All FAQ
-
Why must the final character of the Mersen marking be checked for 170M5388/PC72UD13C250T 3AUA0000090404?The ABB manual lists PC72UD13C250TF, while the supplied reference omits the final F; photograph the fuse label and approve the exact marking before order.
-
How many fuses are documented for the ABRU-02 position of 170M5388/PC72UD13C250T 3AUA0000090404?ABB documents two fuses for each ABRU-02 DC chopper.
-
Which converter relationship should be recorded for 170M5388/PC72UD13C250T 3AUA0000090404?Capture the ACS800 converter type, ABRU chopper identity, cabinet position and companion resistor circuit.
-
What isolation sequence applies before replacing 170M5388/PC72UD13C250T 3AUA0000090404?Use the approved converter shutdown, lockout and DC-link discharge procedure and prove absence of hazardous voltage.
-
Why should the second fuse be inspected when one 170M5388/PC72UD13C250T 3AUA0000090404 fuse fails?Both positions share the chopper protection duty, so heat damage, aging and the fault-current path must be assessed together.
-
Can a fuse with the same current shape automatically replace 170M5388/PC72UD13C250T 3AUA0000090404?No. Rating, melting curve, body size, terminals and manufacturer-approved cross-reference must all agree.
-
What circuit checks follow replacement of 170M5388/PC72UD13C250T 3AUA0000090404?Inspect the chopper semiconductor path, resistor connections, insulation and mounting torque before controlled energization.
-
What evidence completes acceptance of 170M5388/PC72UD13C250T 3AUA0000090404?Retain both fuse markings, continuity and insulation results, chopper diagnostics and the controlled energization record.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.