Match the complete marking
Send the complete 170M6467 3AUA0000062487 marking, revision labels, current-unit photographs and installed position.
-
Check the offered item before ordering
Compare the offered 170M6467 3AUA0000062487 interfaces, ratings and included items with the approved system record before ordering.
Technical specifications for 170M6467 3AUA0000062487
-
Manufacturer:ABB
-
Product Category:DCS Systems
-
Spare Part Number:170M6467 3AUA0000062487
-
Weight:0.45 kg
-
Tariff Code:8537101190
-
Complete product reference:170M6467 3AUA0000062487
-
Product type:Main-Circuit AC High-Speed Fuse
-
System platform:ABB ACS800-67LC and ACS880 liquid-cooled drive systems
-
ABB MRP code:3AUA0000062487
-
Fuse manufacturer series:Eaton Bussmann 170M
-
Fuse type:170M6467
-
Fuse class:Ultrarapid aR
-
Rated current:1400 A
-
Rated voltage:690 V AC
-
I²t at 660 V:2,450,000 A²s
-
Fuse size:Size 3
-
Indicator execution:Type K
-
ABB ACS800 position:Main-circuit AC fuse
-
ABB manual status:UL listed
-
Selection boundary:Rating and melting curve must not exceed documented protection curve
-
Shipping size (est.):20cm x 10cm x 6cm
-
Shipping weight:0.45 kg
-
Country of Origin:Sweden
Information
- ABB 170M6467 3AUA0000062487 is a main-circuit ac high-speed fuse documented for ABB ACS800-67LC and ACS880 liquid-cooled drive systems.
ABB-to-fuse mapping: MRP code 3AUA0000062487 is linked to Bussmann type 170M6467 in the ACS800 hardware manual.
Converter-dependent fuse quantity: Required pieces vary with converter power and pulse configuration and must be taken from the exact drive manual.
The number of fuses depends on converter type and 6-, 12- or 24-pulse construction. The drive nameplate and fuse table must therefore be used together rather than extrapolating quantity from the fuse model.
Before replacement, isolate and discharge the converter, examine the fault path and compare all parallel fuse positions. Tightening, microswitch arrangement where fitted and controlled energization are recorded for handover.
170M6467 3AUA0000062487 Technical Reference
ABB ACS800-67LC and ACS880-07CLC hardware manuals with Eaton Bussmann 170M6467 product data. Exact-model identity and the applicable system evidence are retained without distributor advertising.170M6467 3AUA0000062487 Installation & Verification Guide
Product-specific field guide for identity capture, controlled exchange, commissioning evidence and handover.
Application scope: Use 170M6467 3AUA0000062487 only where the product identity, ratings, companion hardware and approved system documentation agree.
Liquid-cooled drive input protection
Protect approved ACS800 or ACS880 supply-module configurations.High-speed semiconductor circuits
Limit short-circuit let-through energy with the documented aR curve.Parallel-fuse maintenance
Assess all fuse positions and current-sharing connections after a fault.Installed-base spare matching
Match ABB MRP, Bussmann type, drive rating and fuse quantity.
Record type, voltage and pulse configuration.
Complete drive lockout and discharge checks.
Assess every associated fuse and bus connection.
Do not increase current rating or let-through energy.
Use the manufacturer procedure for fuse contacts.
Review diagnostics before power-circuit energization.
Alternative Names
Technical notes
Exact identity: 170M6467 3AUA0000062487
Documented function: Main-Circuit AC High-Speed Fuse
Technical evidence: ABB ACS800-67LC and ACS880-07CLC hardware manuals with Eaton Bussmann 170M6467 product data
Evidence boundary: Only the documented ABB ACS800-67LC and ACS880 liquid-cooled drive systems relationship and stated exact-model values are applied
Commissioning record: Retain installed markings, configuration and functional proof
FAQ View All FAQ
-
Which electrical ratings define 170M6467 3AUA0000062487?The documented fuse is a 1400 A, 690 V AC ultrarapid aR type with 2,450,000 A²s at 660 V.
-
How is ABB article 3AUA0000062487 related to 170M6467 3AUA0000062487?ABB hardware documentation maps that MRP code to Bussmann fuse type 170M6467.
-
Why can the quantity of 170M6467 3AUA0000062487 not be assumed from the fuse model?ABB uses different quantities for converter ratings and 6-, 12- or 24-pulse configurations.
-
What inspection follows a blown 170M6467 3AUA0000062487?Check all parallel fuse positions, busbars, semiconductor modules, insulation and evidence of the initiating fault.
-
Can a higher-current fuse replace 170M6467 3AUA0000062487?No. ABB specifically warns against using a fuse with a higher current rating than the documented recommendation.
-
What must agree when cross-referencing 170M6467 3AUA0000062487?Current, voltage, aR class, melting curve, body size, terminal form and indicator execution must all match.
-
What controlled restart applies after fitting 170M6467 3AUA0000062487?Verify torque and isolation, restore control power, review drive diagnostics, then energize the power circuit under the approved site procedure.
-
What belongs in the final record for 170M6467 3AUA0000062487?Record fuse markings, converter type, quantity, torque, insulation result, fault investigation and controlled-start evidence.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.