Stahl 9468-33-08-10
Stahl 9468-33-08-10
Stahl 9468-33-08-10
Stahl 9468-33-08-10
Stahl 9468-33-08-10
Stahl 9468-33-08-10
Product image is representative; revision or series may vary. Contact us to request a specific version.

9468-33-08-10

IS1+ HART Analogue Universal Module for Zone 2
In Stock

Product Describe:

R. STAHL 9468-33-08-10 is an eight-channel HART analogue universal module for IS1+ Remote I/O in Zone 2. Each channel can be configured as an intrinsically safe analogue input or output with line-fault monitoring.

Ask our team:

Get a quick price for: 9468-33-08-10
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 9468-33-08-10

Technical specifications for 9468-33-08-10

  • Manufacturer:
    Stahl
  • Product Category:
    General Automation
  • Spare Part Number:
    210660
  • Estimated shipping dimensions:
    10.7x11.3x1.6cm
  • Weight:
    0.14 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Official type:
    9468/33-08-10 AUMH 08 Z2
  • Article number:
    210660
  • Channels:
    8
  • Channel function:
    Analogue input or output
  • Signal range:
    0/4 to 20 mA
  • Communication:
    HART
  • Explosion protection:
    Ex ia IIC

Information

Information

Overview Manuals Common Applications Product Precautions
9468-33-08-10 provides eight individually configurable intrinsically safe HART analogue channels for an IS1+ Zone 2 station.
  • Provides eight individually configurable analogue channels
  • Supports 0/4 to 20 mA input and output operation
  • Carries bidirectional HART communication
  • Supports line-fault monitoring and Zone 2 hot swap

The module plugs into BusRail 9494 and interfaces approved Ex i field circuits through the documented IS1+ terminal arrangement. Commissioning verifies channel mode, 0/4 to 20 mA scaling, HART communication, line-fault monitoring and station diagnostics.

Important Notice: Confirm 9468-33-08-10, 9468/33-08-10 AUMH 08 Z2, article 210660, BusRail 9494 position, module hardware execution, terminal and Ex i wiring, channel modes, HART configuration, line-fault settings, shielding, grounding and controlled loop-test status before commissioning.

Apter Power 9468-33-08-10 Manuals and Guides

The first document is the model-specific Apter Power technical reference. The second opens the original R. STAHL product datasheet for type 9468/33-08-10 AUMH 08 Z2.

Zone 2 HART transmitter input
Acquires intrinsically safe 0/4 to 20 mA measurements with HART device communication.
Intrinsically safe control output
Drives approved analogue final elements from a configured IS1+ output channel.
Mixed analogue marshalling
Assigns input and output roles independently across eight field channels.
Remote I/O loop diagnostics
Uses channel LEDs, line-fault monitoring and HART status during controlled maintenance.
Read the applicable R. STAHL installation instructions before work. Verify 9468-33-08-10, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm 9468-33-08-10, official type 9468/33-08-10 AUMH 08 Z2 and article 210660.
2
Place the process loops and final elements in the approved maintenance state.
3
Follow the Zone 2 and intrinsic-safety work procedure and apply ESD controls.
4
Record every channel mode, 0/4 to 20 mA range, HART address and line-fault setting.
5
Verify BusRail 9494 position, terminal assignment, cable shield and Ex i circuit segregation.
6
Restore the approved IS1+ station and channel configuration before loop energization.
7
Review module and channel LEDs, line-fault status and HART communication loop by loop.
8
Complete controlled input simulation and output proof tests before returning the station to service.

Technical notes

Technical notes

Install 9468-33-08-10 on the documented BusRail 9494 position and record every channel's input/output mode, HART assignment, intrinsically safe field circuit and line-fault setting before removal. Restore the approved IS1+ configuration and prove each loop, diagnostic LED and HART communication under controlled conditions.

FAQS

  • Which IS1+ carrier is required for 9468-33-08-10?
    Use the documented BusRail 9494 position and preserve the approved IS1+ station and terminal arrangement.
  • How many channels does 9468-33-08-10 provide?
    The module provides eight channels, each configurable as an analogue input or analogue output.
  • Which signal and protocol does 9468-33-08-10 support?
    Each channel supports 0/4 to 20 mA operation with bidirectional HART communication.
  • Can 9468-33-08-10 be replaced while the Zone 2 station remains energized?
    The official record supports hot swap in Zone 2, subject to the approved hazardous-area and intrinsic-safety work procedure.
  • What must be recorded before removing 9468-33-08-10?
    Record BusRail position, terminal map, input/output role, scaling, HART assignment, line-fault setting, shields and Ex i loop identity for all eight channels.
  • What line diagnostics are available on 9468-33-08-10?
    The module provides line-fault monitoring and channel status indication; verify the configured diagnostics after installation.
  • How should the outputs of 9468-33-08-10 be verified?
    Test each configured output with the approved loop load and confirm the expected 0/4 to 20 mA response without bypassing process interlocks.
  • What completes commissioning of 9468-33-08-10?
    Confirm IS1+ recognition, channel LEDs, line-fault status, HART communication and controlled input/output loop tests for every assigned channel.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.