Technical specifications for 9468-33-08-10
-
Manufacturer:Stahl
-
Product Category:General Automation
-
Spare Part Number:210660
-
Estimated shipping dimensions:10.7x11.3x1.6cm
-
Weight:0.14 kg
-
Tariff Code:8537101190
-
Counliy of origin:Germany
-
Official type:9468/33-08-10 AUMH 08 Z2
-
Article number:210660
-
Channels:8
-
Channel function:Analogue input or output
-
Signal range:0/4 to 20 mA
-
Communication:HART
-
Explosion protection:Ex ia IIC
Information
- Provides eight individually configurable analogue channels
- Supports 0/4 to 20 mA input and output operation
- Carries bidirectional HART communication
- Supports line-fault monitoring and Zone 2 hot swap
The module plugs into BusRail 9494 and interfaces approved Ex i field circuits through the documented IS1+ terminal arrangement. Commissioning verifies channel mode, 0/4 to 20 mA scaling, HART communication, line-fault monitoring and station diagnostics.
Important Notice: Confirm 9468-33-08-10, 9468/33-08-10 AUMH 08 Z2, article 210660, BusRail 9494 position, module hardware execution, terminal and Ex i wiring, channel modes, HART configuration, line-fault settings, shielding, grounding and controlled loop-test status before commissioning.
Apter Power 9468-33-08-10 Manuals and Guides
- Apter Power 9468-33-08-10 IS1+ Channel and HART Technical Reference PDF
- Apter Power R. STAHL 9468/33-08-10 Official Product Datasheet PDF
The first document is the model-specific Apter Power technical reference. The second opens the original R. STAHL product datasheet for type 9468/33-08-10 AUMH 08 Z2.
Technical notes
FAQ View All FAQ
-
Which IS1+ carrier is required for 9468-33-08-10?Use the documented BusRail 9494 position and preserve the approved IS1+ station and terminal arrangement.
-
How many channels does 9468-33-08-10 provide?The module provides eight channels, each configurable as an analogue input or analogue output.
-
Which signal and protocol does 9468-33-08-10 support?Each channel supports 0/4 to 20 mA operation with bidirectional HART communication.
-
Can 9468-33-08-10 be replaced while the Zone 2 station remains energized?The official record supports hot swap in Zone 2, subject to the approved hazardous-area and intrinsic-safety work procedure.
-
What must be recorded before removing 9468-33-08-10?Record BusRail position, terminal map, input/output role, scaling, HART assignment, line-fault setting, shields and Ex i loop identity for all eight channels.
-
What line diagnostics are available on 9468-33-08-10?The module provides line-fault monitoring and channel status indication; verify the configured diagnostics after installation.
-
How should the outputs of 9468-33-08-10 be verified?Test each configured output with the approved loop load and confirm the expected 0/4 to 20 mA response without bypassing process interlocks.
-
What completes commissioning of 9468-33-08-10?Confirm IS1+ recognition, channel LEDs, line-fault status, HART communication and controlled input/output loop tests for every assigned channel.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.