Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 6DP1210-8BC
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 6DP1210-8BC

  • Manufacturer:
    Siemens
  • Product Category:
    DCS Systems
  • Spare Part Number:
    6DP1210-8BC
  • Estimated shipping dimensions:
    2x26.4x26.2cm
  • Weight:
    0.4 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Module designation:
    FUM 210
  • Hardware type:
    Binary signal module
  • System context:
    TELEPERM XP AS 620 / S7 variants
  • Binary inputs:
    28
  • Binary outputs:
    16
  • Primary function:
    Binary signal recording and output control
  • Variant control:
    Match the installed function execution
  • Pre-removal record:
    Complete I/O map and diagnostic state
  • Acceptance:
    Input forcing and controlled output response

Information

Overview Manuals Common Applications Product Precautions
Siemens 6DP1210-8BC concentrates discrete plant states and commands in the FUM 210 position, making its complete input/output map the basis for replacement.
  • 6DP1210-8BC
  • FUM 210
  • Binary signal module
  • TELEPERM XP AS 620 / S7 variants

The 28 input indications and 16 output responses are commissioned one channel at a time while command paths remain safely inhibited until their checks pass.

Important Notice: Capture the complete I/O map and installed function variant before removing FUM 210.

Siemens 6DP1210-8BC Manuals & Downloads
Siemens 6DP1210-8BC Technical Reference (PDF)Siemens 6DP1210-8BC Installation & Commissioning Guide (PDF)

The technical reference maps the FUM 210 channel allocation and system role; the field guide separates safe inhibition, conductor control, input proving and output release.

AS 620 discrete-I/O renewal
Restores the FUM 210 position with the same 28-input and 16-output allocation.
Binary status acquisition
Returns specified plant contacts and interlock states to the controller image.
Command-path restoration
Reinstates the recorded output channels without changing permissive logic.
Migration-stage verification
Supports controlled comparison where a specified S7 function variant is retained.
Use this sequence to verify 6DP1210-8BC without unintentionally enabling a FUM 210 field command.
1
Confirm 6DP1210-8BC and FUM 210 before disconnecting the front assembly.
2
Export or photograph the complete 28-input and 16-output signal map.
3
Identify the installed AS 620 or S7 function variant in the engineering record.
4
Place every affected command path in a safe inhibited state.
5
Label common, return and field conductors before module removal.
6
Check the replacement channel image before enabling any output group.
7
Prove each input with its expected controller indication.
8
Exercise outputs individually under controlled field supervision before handover.

Technical notes

Match 6DP1210-8BC to the complete installed identity and TELEPERM XP AS 620 / S7 position. Preserve every connection and setting; release only after controlled verification of recording 28 binary states and controlling 16 binary output paths.

FAQ View All FAQ

  • What is Siemens 6DP1210-8BC FUM 210 used for?
    It records binary plant signals and provides binary output channels in a TELEPERM XP automation position.
  • How many inputs are associated with Siemens 6DP1210-8BC?
    The module provides 28 binary inputs.
  • How many outputs are associated with Siemens 6DP1210-8BC?
    The module provides 16 binary outputs.
  • Which system context is specified for Siemens 6DP1210-8BC?
    The module is identified for TELEPERM XP AS 620 and related S7 function variants.
  • Why must the function variant of Siemens 6DP1210-8BC be checked?
    Channel behavior depends on the installed engineering execution, not only on the visible hardware.
  • What is the essential pre-removal record for Siemens 6DP1210-8BC?
    Retain the full I/O address map, wire labels, enabled outputs and diagnostic state.
  • How are the input channels of Siemens 6DP1210-8BC commissioned?
    Operate or simulate each field state and confirm the corresponding controller indication.
  • How are the FUM 210 outputs of Siemens 6DP1210-8BC released?
    Enable and test one controlled output at a time while observing the real field response.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.