Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 6ES7307-1KA00-0AA0
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 6ES7307-1KA00-0AA0

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6ES7307-1KA00-0AA0
  • Estimated shipping dimensions:
    6x12.2x12.5cm
  • Weight:
    0.5 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Product family:
    SIMATIC S7
  • Power-supply type:
    PS 307-1K
  • Input:
    120/230 V AC
  • Output voltage:
    24 V DC
  • Output current:
    10 A
  • Application:
    S7-300 and ET 200M station power

Information

Overview Manuals Common Applications Product Precautions
Siemens 6ES7307-1KA00-0AA0 provides the 10 A PS 307-1K 24 V DC supply function for a SIMATIC station.
  • Accepts a 120/230 V AC input selection.
  • Provides a regulated 24 V DC output.
  • Supplies up to the documented 10 A output rating.
  • Uses the SIMATIC S7-300 form factor for station integration.

The power supply serves a defined role in its documented SIMATIC system. Match the rack, interfaces, configuration and program safeguards before the controlled system returns to service.

Important Notice: Verify the complete Siemens 6ES7307-1KA00-0AA0 marking, system position, connector arrangement and controlled configuration before installation.

Siemens 6ES7307-1KA00-0AA0 Manuals & Downloads
Siemens 6ES7307-1KA00-0AA0 Technical Reference (PDF)Siemens 6ES7307-1KA00-0AA0 Installation & Commissioning Guide (PDF)

The Technical Reference covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.

S7-300 station power
Supply the CPU and signal-module load within the documented current budget.
ET 200M cabinet power
Provide regulated 24 V DC where a local AC-fed station supply is required.
Machine-control cabinet
Power compatible SIMATIC modules and protected auxiliary circuits.
Maintenance replacement
Restore the same PS 307 voltage and current execution in an existing station.
Before installing Siemens 6ES7307-1KA00-0AA0, confirm the documented system, interfaces and controlled configuration.
1
Confirm the complete 6ES7307-1KA00-0AA0 article number and PS 307-1K designation.
2
Verify the available mains voltage and the selected 120/230 V AC setting.
3
Isolate incoming AC and stored energy before wiring or removal.
4
Confirm protective-earth, line, neutral and 24 V DC polarity connections.
5
Calculate the station current demand against the 10 A output rating.
6
Keep ventilation clear and retain the documented mounting orientation.
7
Check 24 V DC output before connecting the controller load.
8
Verify the station remains stable through startup and the intended operating load.

Technical notes

Verify the complete Siemens 6ES7307-1KA00-0AA0 marking, system position, connector arrangement and controlled configuration before installation.

FAQ View All FAQ

  • What type of device is Siemens 6ES7307-1KA00-0AA0?
    It is a SIMATIC PS 307-1K regulated power supply.
  • Which input supply is specified for Siemens 6ES7307-1KA00-0AA0?
    The input is selectable for 120 or 230 V AC.
  • What output does Siemens 6ES7307-1KA00-0AA0 provide?
    It provides 24 V DC at the documented 10 A rating.
  • Which station families can use Siemens 6ES7307-1KA00-0AA0?
    The PS 307 format supports applicable S7-300 and ET 200M station arrangements.
  • What must be checked before energizing Siemens 6ES7307-1KA00-0AA0?
    Check mains selection, protective earth, polarity and the calculated current demand.
  • What completes commissioning of Siemens 6ES7307-1KA00-0AA0?
    Verify the 24 V DC output and stable station operation through startup and load testing.
  • Which installation records should accompany Siemens 6ES7307-1KA00-0AA0?
    Record the complete article number, power supply position, connections, controlled settings and functional test result.
  • When can Siemens 6ES7307-1KA00-0AA0 return to service?
    Return it to service only after diagnostics, communication, interlocks and the intended system response meet the approved acceptance criteria.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.