Match the complete marking
Include 6ES7 313-6CF03-0AB0 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 6ES7 313-6CF03-0AB0 with the installed equipment and applicable Siemens documentation.
Technical specifications for 6ES7 313-6CF03-0AB0
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:6ES7313-6CF03-0AB0
-
Weight:0.1 kg
-
Tariff Code:8537101190
-
CPU design:CPU 313C-2 DP
-
Work memory:64 KB; not expandable
-
Load memory:SIMATIC Micro Memory Card; maximum 8 MB
-
Integrated digital inputs:16
-
Integrated digital outputs:16
-
Integrated analog channels:None
-
Rated supply:24 V DC
-
Permissible supply:20.4-28.8 V DC
-
Power loss:10 W typical
-
MPI data rate:Maximum 187.5 kbit/s
-
DP interface:Isolated RS485; master or slave
-
DP transmission rate:Up to 12 Mbaud
-
DP slaves per station:Maximum 32
-
Integrated counters:3 channels; frequency measurement up to 30 kHz
-
PWM outputs:3 channels; maximum 2.5 kHz
-
S7 timers / counters:256 / 256
-
Diagnostics buffer:Maximum 100 entries
-
Programming package:STEP 7 V5.4 SP3 or later; V5.3 SP2 with HSP 0123 also supported
Information
- The integrated digital I/O and dedicated DP interface let Siemens 6ES7 313-6CF03-0AB0 coordinate local machine signals and distributed stations within an S7-300 automation system.
Local I/O: 16 digital inputs and 16 digital outputs; no integrated analog channels
Network: MPI and isolated RS485 PROFIBUS DP interface
Local control uses 16 digital inputs and 16 digital outputs; analog signals require suitable expansion or distributed modules. Three integrated counting channels support frequency measurement up to 30 kHz, and three PWM outputs operate up to 2.5 kHz. These technology functions share hardware resources with the configured digital terminals.
The first communication interface supports MPI at up to 187.5 kbit/s. The second is an isolated RS485 PROFIBUS DP interface for master or slave operation at up to 12 Mbaud. As a DP master the CPU can serve up to 32 slaves; the station data and address limits still apply. This variant does not provide isochronous DP master operation or constant bus cycle time.
6ES7 313-6CF03-0AB0 Official Technical Reference Excerpt
SIMATIC S7-300 CPU 31xC and CPU 31x: Specifications, A5E00105475-08, 06/2008: preserved manufacturer specifications applicable to this product configuration. PDF · 7 pages.6ES7 313-6CF03-0AB0 Installation & Verification Guide
Apter Power field guide for project backup, supply and I/O checks, MPI/DP configuration and controlled restart. PDF · 5 pages.
Application scope: Applications use the configured STEP 7 logic, local digital I/O and compatible distributed modules. No safety-controller capability or integrated analog I/O is implied.
Local sequence control
Use the 16 DI and 16 DO to execute configured machine sequencing and discrete interlocks.Distributed I/O coordination
Operate a configured PROFIBUS DP master network with up to 32 slaves within CPU data limits.Pulse and frequency tasks
Use the integrated counting, frequency or PWM functions with their assigned terminals and signal limits.S7-300 program maintenance
Retain the MMC, STEP 7 hardware configuration and diagnostics for an existing CPU 313C-2 DP installation.
Match the complete 6CF03 order code and firmware; do not substitute PtP interface settings.
Back up the program, hardware configuration, retentive-data requirements and network addresses.
Place machinery and output circuits in the approved safe state before disconnecting wiring.
Verify 20.4-28.8 V DC at the CPU and the protective circuit design before energization.
Check integrated I/O addresses and technology-function assignments before enabling outputs.
Check DP diagnostics, station recognition and the controlled response to a communication loss.
Alternative Names
Technical notes
Memory relationship: The MMC provides load memory; the 64 KB working-memory capacity remains fixed.
Communication boundary: DP master and slave capabilities differ. Do not apply PtP serial features or isochronous-operation assumptions to this CPU.
FAQ View All FAQ
-
Can 6ES7 313-6CF03-0AB0 expand its 64 KB working memory with a larger MMC?No. Working memory is fixed at 64 KB. A SIMATIC Micro Memory Card provides separate load memory, with a supported capacity up to 8 MB; it does not enlarge the working-memory area.
-
Which analog signals can connect directly to 6ES7 313-6CF03-0AB0?The CPU has no integrated analog input or output channels. Analog signals require suitable expansion or distributed I/O modules configured in the STEP 7 project.
-
How do the two communication interfaces on 6ES7 313-6CF03-0AB0 differ?The first interface provides MPI at up to 187.5 kbit/s. The second is an electrically isolated RS485 PROFIBUS DP interface that can operate as a DP master or slave at up to 12 Mbaud.
-
How many DP slaves can 6ES7 313-6CF03-0AB0 address as a master?The integrated DP master supports up to 32 DP slaves. Address-space, data-length and connection limits must also be respected when assigning the station configuration.
-
What pulse functions are integrated into 6ES7 313-6CF03-0AB0?Three counter channels support counting, frequency measurement up to 30 kHz and cycle-duration measurement. Three PWM outputs support frequencies up to 2.5 kHz.
-
Does 6ES7 313-6CF03-0AB0 support isochronous DP master operation?No. The CPU 313C-2 DP master specification does not support isochronous mode or constant bus cycle time. SYNC/FREEZE and DPV1 are supported in the DP master role.
-
Which supply range is permitted for 6ES7 313-6CF03-0AB0?The rated supply is 24 V DC and the permitted range is 20.4-28.8 V DC. Check supply voltage at the CPU during startup and load changes rather than only at the power supply terminals.
-
What diagnostic history can 6ES7 313-6CF03-0AB0 retain for fault investigation?The CPU provides a diagnostics buffer with up to 100 entries. Capture the buffer before clearing a fault or changing the program so that the sequence of CPU and communication events can be reviewed.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.