Match the complete marking
Include 6DD1681-0CA2 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 6DD1681-0CA2 with the installed equipment and applicable Siemens documentation.
Technical specifications for 6DD1681-0CA2
-
Manufacturer:Siemens
-
Product Category:General Automation
-
Spare Part Number:6DD1681-0CA2
-
Weight:0.54 kg
-
Tariff Code:8537101190
-
Module designation:SE20.2
-
System family:SIMADYN D
-
Function:SITOR interface
-
PG26 association:Listed SITOR-interface board
-
ITDC connection:SE20.2 X3 to ITDC X7 in the applicable arrangement
-
Cabinet pulse connection:X1 to pulse distribution
-
Feedback and monitoring:X2 from cabinet transfer module
-
Rack allocation:3 slots in the described SIMADYN D arrangement
-
Backplane coupling:No backplane-bus coupling in the described arrangement
Information
- Siemens 6DD1681-0CA2 provides the signal interface between a configured control arrangement and the SITOR power section. The installed processor, converter and connection drawings determine the complete application.
Module designation: SE20.2
System context: SIMADYN D converter control
In the D7-SYS ITDC and SITOR-cabinet arrangement, SE20.2 connects converter signals to the control interface with electrical isolation. It occupies three SIMADYN D subrack slots and has a rear voltage connection without a backplane-bus coupling. This describes the applicable cabinet integration and does not imply that a processor, subrack or converter is included with the offered module.
For that ITDC arrangement, SE20.2 connector X3 connects to ITDC X7. Connector X1 carries firing pulses toward the cabinet pulse distribution; X2 receives actual-value and monitoring signals. Preserve the specified grounding and shield connections at the interface and cabinet, and verify the installed connector assignments before reconnecting the power section.
-
Siemens 6DD1681-0CA2 technical reference
Original Siemens excerpt - PDF, 4 pages, 18.1 KB. SE20.2 identification and SITOR connection guidance apply. PG26 and ITDC processor ratings are not ratings of this interface module. -
Siemens 6DD1681-0CA2 installation planning guide
Prepared by Apter Power - PDF, 5 pages, 96.1 KB. Identity, configuration, connection and controlled acceptance planning.
Platform applications: The following applications describe SIMADYN D SE20.2 functions. Match the complete 6DD1681-0CA2 identity to the installed system before selecting a replacement.
-
SITOR cabinet coupling
Connect the configured controller interface and SITOR power section using the matching SE20.2 arrangement. -
Firing-pulse distribution
Preserve the X1 connection to cabinet pulse distribution and its grounding arrangement. -
Converter feedback
Retain the X2 actual-value and monitoring connections against the cabinet drawing. -
Legacy interface service
Identify the installed SE20.2, processor and cabling before replacing the interface board.
Place the drive in a safe state and isolate the power section and control supplies before handling the interface.
Check the full 6DD1681-0CA2 and SE20.2 marking against the installed unit.
Record X1, X2 and X3 wiring and retain the approved cabinet connection diagram.
Restore the specified shield and ground terminations at the module and cabinet.
Do not apply PG26 or ITDC processor specifications as SE20.2 electrical ratings.
Verify pulse, feedback and monitoring paths under the approved commissioning procedure before enabling the converter.
Alternative Names
Technical notes
Installation relationship: In the D7-SYS ITDC and SITOR-cabinet arrangement, SE20.2 connects converter signals to the control interface with electrical isolation. It occupies three SIMADYN D subrack slots and has a rear voltage connection without a backplane-bus coupling. This describes the applicable cabinet integration and does not imply that a processor, subrack or converter is included with the offered module.
Configuration: SE20.2 identification and SITOR connection guidance apply. PG26 and ITDC processor ratings are not ratings of this interface module.
Technical reference: Siemens PG26 User Manual, Dk-Nr. 222342, Edition 05.95; D7-SYS SIMADYN D system and communication configuring, Edition 06.2002.
FAQ View All FAQ
-
What is the function of 6DD1681-0CA2?It is the SE20.2 interface board used in a configured SITOR converter connection.
-
Is 6DD1681-0CA2 itself a PG26 processor?No. SE20.2 is an associated interface board; PG26 processor and memory ratings do not describe it.
-
How is 6DD1681-0CA2 connected to ITDC?In the applicable D7-SYS arrangement, SE20.2 X3 connects to the ITDC X7 SITOR interface.
-
Which connector carries firing pulses on 6DD1681-0CA2?X1 carries the isolated firing-pulse connection toward the SITOR cabinet pulse distribution in the described arrangement.
-
Which connector receives feedback on 6DD1681-0CA2?X2 receives actual-value and monitoring signals from the cabinet transfer module.
-
How many rack slots does 6DD1681-0CA2 occupy in the described arrangement?The SE20.2 arrangement occupies three SIMADYN D subrack slots.
-
Does 6DD1681-0CA2 couple to the backplane bus in that arrangement?No. The rear connector provides the voltage connection without a backplane-bus coupling.
-
Which cable arrangement is associated with 6DD1681-0CA2 in a PG26 installation?The PG26 SITOR connection uses the specified screened round cables with twisted-pair conductors. Match the complete cable and connector drawing to the installation.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.