6SE7041-8EK85-1HA0

Siemens PER2 Rectifier Interface Module

Product Describe:

6SE7041-8EK85-1HA0 is a Siemens PER2 rectifier interface module for infeed/regenerative-feedback supply units in designs H and K. The official assignment is 380-480 V, 3 AC, 50/60 Hz. It is a component of the supply unit, rather than a complete motor converter.

Its documented role is the rectifier interface inside the assigned supply unit. At system level, the rectifying bridge feeds the DC link during motoring; the regenerative bridge transfers energy from that link back toward the supply during generating operation. Individual interface signals, connector pinouts and signal levels are not specified in the exact article entry.

Ask our team:

Get a quick price for: 6SE7041-8EK85-1HA0
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 6SE7041-8EK85-1HA0

Technical specifications for 6SE7041-8EK85-1HA0

  • Manufacturer:
    Siemens
  • Product Category:
    Server Driver
  • Spare Part Number:
    6SE7041-8EK85-1HA0
  • Estimated shipping dimensions:
    54.5 x 37.5 x 6 cm (L x W x H)
  • Weight:
    1.32 kg
  • Component type:
    Rectifier interface module
  • Interface designation:
    PER2
  • Host function:
    Infeed / regenerative feedback supply unit
  • Assigned designs:
    H and K
  • Host supply voltage:
    380-480 V, 3 AC
  • Host supply frequency:
    50/60 Hz
  • Lifecycle:
    Discontinued (current article)

Information

Information

Overview Manuals Common Applications Product Precautions
6SE7041-8EK85-1HA0 is a Siemens PER2 rectifier interface module for infeed/regenerative-feedback supply units in designs H and K. The official assignment is 380-480 V, 3 AC, 50/60 Hz. It is a component of the supply unit, rather than a complete motor converter.
  • Component type: Rectifier interface module
  • Interface designation: PER2
  • Host function: Infeed / regenerative feedback supply unit
  • Assigned designs: H and K

Its documented role is the rectifier interface inside the assigned supply unit. At system level, the rectifying bridge feeds the DC link during motoring; the regenerative bridge transfers energy from that link back toward the supply during generating operation. Individual interface signals, connector pinouts and signal levels are not specified in the exact article entry.

The system combines the assigned H/K supply unit, its control electronics and power section with the DC link and downstream inverters. The Siemens system manual identifies CUR control electronics and an optional OCP in this architecture. An OCP is a separate system component.

PER2 and the exact voltage assignment are essential identifiers. Do not assume interchangeability with other PER versions. The voltage range describes the host supply-unit assignment, not a low-voltage signal rating for the PCB. The current manufacturer listing marks this article discontinued; a generic migration note does not identify a drop-in replacement.

6SE7041-8EK85-1HA0 Manuals and Technical Guide

The Apter Power PDF is an original summary based on the linked manufacturer references; it is not a Siemens-issued manual.

Industrial drive systems
For industrial drive systems using the documented infeed/regenerative-feedback architecture, including duty with power flow to the motors and regenerated energy returning through the supply unit. Match the exact host equipment and voltage class before selecting the interface module.

Equipment integration
The system combines the assigned H/K supply unit, its control electronics and power section with the DC link and downstream inverters. The Siemens system manual identifies CUR control electronics and an optional OCP in this architecture. An OCP is a separate system component.

Use the equipment-specific Siemens manual and approved component assignment.

  • Match the exact article, host equipment and hardware revision before installation.
  • Isolate all supplies, verify the absence of voltage, observe the specified discharge time and grounding requirements.
  • Installation and service require qualified personnel and appropriate electrostatic-discharge precautions.
  • PER2 and the exact voltage assignment are essential identifiers. Do not assume interchangeability with other PER versions. The voltage range describes the host supply-unit assignment, not a low-voltage signal rating for the PCB. The current manufacturer listing marks this article discontinued; a generic migration note does not identify a drop-in replacement.

Alternative Names

Alternative Names

6SE70418EK851HA0

Technical notes

Technical notes

PER2 and the exact voltage assignment are essential identifiers. Do not assume interchangeability with other PER versions. The voltage range describes the host supply-unit assignment, not a low-voltage signal rating for the PCB. The current manufacturer listing marks this article discontinued; a generic migration note does not identify a drop-in replacement.

FAQS

  • What is 6SE7041-8EK85-1HA0?
    6SE7041-8EK85-1HA0 is a Siemens PER2 rectifier interface module for infeed/regenerative-feedback supply units in designs H and K. The official assignment is 380-480 V, 3 AC, 50/60 Hz. It is a component of the supply unit, rather than a complete motor converter.
  • What is its system function?
    Its documented role is the rectifier interface inside the assigned supply unit. At system level, the rectifying bridge feeds the DC link during motoring; the regenerative bridge transfers energy from that link back toward the supply during generating operation. Individual interface signals, connector pinouts and signal levels are not specified in the exact article entry.
  • Which components and equipment are used with it?
    The system combines the assigned H/K supply unit, its control electronics and power section with the DC link and downstream inverters. The Siemens system manual identifies CUR control electronics and an optional OCP in this architecture. An OCP is a separate system component.
  • What must be checked before installation?
    PER2 and the exact voltage assignment are essential identifiers. Do not assume interchangeability with other PER versions. The voltage range describes the host supply-unit assignment, not a low-voltage signal rating for the PCB. The current manufacturer listing marks this article discontinued; a generic migration note does not identify a drop-in replacement.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.