Speak to a sourcing specialist
sales13@apterpower.com

6SE7041-8HK85-1HA0

Siemens PER2 Rectifier Interface Module
In Stock
Ships by Friday, November 6
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

6SE7041-8HK85-1HA0 is a Siemens PER2 rectifier interface module for infeed/regenerative-feedback supply units in designs H and K. It provides the designated interface for the 500-575 V and 660-690 V, 3 AC, 50/60 Hz host supply-unit execution.

Get a quick price for 6SE7041-8HK85-1HA0
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 6SE7041-8HK85-1HA0

  • Manufacturer:
    Siemens
  • Product Category:
    Servo Drives
  • Spare Part Number:
    6SE7041-8HK85-1HA0
  • Estimated shipping dimensions:
    62.2x14.5x3.5cm
  • Weight:
    0.35 kg
  • Tariff Code:
    85049090
  • Counliy of origin:
    Germany
  • Component type:
    Rectifier interface module
  • Interface designation:
    PER2
  • Host function:
    Infeed / regenerative-feedback supply unit
  • Assigned designs:
    H and K
  • Host supply voltage:
    500-575 V and 660-690 V, 3 AC
  • Host supply frequency:
    50/60 Hz
  • Lifecycle:
    Product cancellation

Information

Overview Manuals Common Applications Product Precautions
6SE7041-8HK85-1HA0 provides the PER2 interface position within the specified SIMOVERT MASTERDRIVES infeed/regenerative-feedback supply-unit arrangement.
  • Identifies the exact PER2 rectifier-interface execution
  • Supports the documented infeed and regenerative-feedback host function
  • Matches the defined design H or K supply-unit architecture
  • Maintains the engineered interface path during controlled service

The module is installed only in the documented design H or K supply unit for 500-575 V and 660-690 V, 3 AC at 50/60 Hz. Replacement work preserves the host-unit identity, connector pattern and existing project configuration before controlled energization.

Important Notice: Confirm 6SE7041-8HK85-1HA0, PER2, design H/K host, 500-575 V and 660-690 V, 3 AC voltage class, 50/60 Hz supply, installed hardware revision, connector assignments, grounding, drive configuration, related accessories and controlled diagnostic results before commissioning.

Apter Power 6SE7041-8HK85-1HA0 Manuals and Guides

The first document is the model-specific technical and system reference. The second is a distinct field workbook for installation, wiring, commissioning and acceptance records.

High-voltage design H/K supply-unit service
Restores the documented PER2 interface in an installed high-voltage infeed/regenerative-feedback unit.
Regenerative line-side converter maintenance
Preserves the interface position used by the host unit during controlled energy-feedback operation.
Legacy MASTERDRIVES refurbishment
Provides exact article identity for a planned PER2 board exchange in the existing drive cabinet.
Controlled supply-unit recommissioning
Supports documented connector restoration and diagnostics after interface-module replacement.
Read the applicable Siemens installation instructions before work. Verify 6SE7041-8HK85-1HA0, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Verify the complete 6SE7041-8HK85-1HA0 marking and PER2 designation.
2
Confirm the installed host is a design H or K infeed/regenerative-feedback supply unit.
3
Prove the host supply and DC link isolated and discharged before module access.
4
Record the PER2 connector positions, cable IDs and shielding before disconnection.
5
Check that the host is the documented 500-575 V or 660-690 V execution.
6
Protect the interface board and connector contacts with ESD-safe handling.
7
Restore only the recorded drive configuration and installed accessories.
8
Energize in the approved sequence and review supply-unit diagnostics before enabling operation.

Alternative Names

6SE70418HK851HA0

Technical notes

Match 6SE7041-8HK85-1HA0 to the documented PER2 execution, the installed design H or K supply unit and the exact 500-575 V and 660-690 V, 3 AC voltage class. Isolate the drive and DC link, preserve every connector assignment, then complete controlled supply-unit diagnostics before return to service.

FAQ View All FAQ

  • What equipment assignment must be confirmed before fitting 6SE7041-8HK85-1HA0?
    Confirm a Siemens design H or K infeed/regenerative-feedback supply unit with the official PER2 assignment.
  • Which voltage executions are documented for 6SE7041-8HK85-1HA0?
    The official article record assigns 500-575 V and 660-690 V, 3 AC, at 50/60 Hz.
  • How should the PER2 connections for 6SE7041-8HK85-1HA0 be preserved?
    Record connector positions, cable identifiers and shielding before removal, then reproduce the documented arrangement.
  • Does 6SE7041-8HK85-1HA0 replace a complete drive converter?
    No. It is the rectifier-interface module inside the assigned supply-unit architecture.
  • What must be checked before energizing 6SE7041-8HK85-1HA0?
    Confirm host identity, voltage class, hardware revision, connectors, grounding and a discharged DC link.
  • Which configuration records matter when replacing 6SE7041-8HK85-1HA0?
    Preserve the installed supply-unit and drive project versions together with connector and accessory records.
  • How is 6SE7041-8HK85-1HA0 validated after installation?
    Use the approved energization sequence and review supply-unit diagnostics before enabling the connected drive system.
  • Why must the full suffix of 6SE7041-8HK85-1HA0 be checked?
    The PER2 designation and high-voltage assignment distinguish it from PER3 and other SIMOVERT interface boards.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.