Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

6SE7031-7HG84-1JC1

SIMOVERT MASTERDRIVES IGD5 inverter gating module
In Stock
Ships by Wednesday, September 16
Fast Shipping Available

Product Describe:

Siemens 6SE7031-7HG84-1JC1 is simovert masterdrives igd5 inverter gating module. It generates the documented inverter gate-drive function for a 171 A SIMOVERT MASTERDRIVES power section.

Ask our team:

Get a quick price for: 6SE7031-7HG84-1JC1
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 6SE7031-7HG84-1JC1

Technical specifications for 6SE7031-7HG84-1JC1

  • Manufacturer:
    Siemens
  • Product Category:
    Server Driver
  • Spare Part Number:
    6SE7031-7HG84-1JC1
  • Estimated shipping dimensions:
    57.5x30x3cm
  • Weight:
    0.72 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Module designation:
    IGD5
  • Equipment class:
    Inverter gating module
  • AC device voltage:
    660-690 V 3 AC
  • AC frequency:
    50/60 Hz
  • DC-link voltage:
    890-930 V DC
  • Device current:
    171 A
  • Successor article:
    6SE7031-7HG84-1JC2

Information

Information

Overview Manuals Common Applications Product Precautions
Siemens 6SE7031-7HG84-1JC1 is simovert masterdrives igd5 inverter gating module. It generates the documented inverter gate-drive function for a 171 A SIMOVERT MASTERDRIVES power section.
  • Controls the inverter switching devices through the IGD5 interface
  • Matches 660-690 V three-phase device hardware
  • Supports a 890-930 V DC-link power section
  • Provides the predecessor configuration for the JC2 replacement article

6SE7031-7HG84-1JC1 is installed with compatible 171 A SIMOVERT MASTERDRIVES power section, installed gate-drive harness, matching control electronics, approved converter commissioning record.

Engineered applications include High-voltage inverter power-section service, Masterdrives cabinet restoration, Gate-drive signal-path verification, Controlled JC1-to-JC2 replacement planning.

Important Notice: Isolate and discharge the DC link, verify zero energy, record every gate-drive connector and power-section position, then prove pulse blocking and controlled inverter response before enabling the motor.

Apter Power 6SE7031-7HG84-1JC1 Manuals and Guides

Apter Power 6SE7031-7HG84-1JC1 Product Technical Reference PDF6SE7031-7HG84-1JC1 Engineering Installation and Verification Workbook

The first document presents model-specific technical identity and engineering data. The second provides a separate installation, connection and commissioning workflow.

High-voltage inverter power-section service

6SE7031-7HG84-1JC1 supports this documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware engineering task.

Masterdrives cabinet restoration

6SE7031-7HG84-1JC1 supports this documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware engineering task.

Gate-drive signal-path verification

6SE7031-7HG84-1JC1 supports this documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware engineering task.

Controlled JC1-to-JC2 replacement planning

6SE7031-7HG84-1JC1 supports this documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware engineering task.

Read the applicable Siemens instructions before work. Verify 6SE7031-7HG84-1JC1 and the installed-system configuration.
1

Verify the complete 6SE7031-7HG84-1JC1 marking and its documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware position before field work.

2

Place the connected equipment in the approved maintenance state before removing 6SE7031-7HG84-1JC1.

3

Isolate every applicable power, signal and stored-energy source, then prove a safe state at 6SE7031-7HG84-1JC1.

4

Record the installed connectors, terminals, jumpers and channel or node assignments before disconnection.

5

Use ESD controls and protect keyed interfaces, edge connectors and exposed electronic assemblies.

6

Restore only the approved SIMOVERT MASTERDRIVES 660-690 V inverter hardware hardware arrangement and configuration after replacement.

7

Energize 6SE7031-7HG84-1JC1 in the documented sequence and review local, host and network diagnostics.

8

Prove the intended controlled function and retain the final acceptance record before production release.

Technical notes

Technical notes

Isolate and discharge the DC link, verify zero energy, record every gate-drive connector and power-section position, then prove pulse blocking and controlled inverter response before enabling the motor.

FAQS

  • What system function does 6SE7031-7HG84-1JC1 provide?
    6SE7031-7HG84-1JC1 is the simovert masterdrives igd5 inverter gating module used in the documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware arrangement. It generates the documented inverter gate-drive function for a 171 A SIMOVERT MASTERDRIVES power section.
  • Which host hardware must be checked before installing 6SE7031-7HG84-1JC1?
    Confirm the exact SIMOVERT MASTERDRIVES 660-690 V inverter hardware host, assigned position, mating connectors and companion hardware against the controlling manufacturer record for 6SE7031-7HG84-1JC1.
  • What wiring or connector record is required before replacing 6SE7031-7HG84-1JC1?
    Record every connector identifier, terminal, conductor, polarity, shield, jumper and channel or node assignment before removal.
  • How should power be isolated for 6SE7031-7HG84-1JC1?
    Follow the equipment-specific isolation procedure, remove applicable control and field energy, discharge stored energy and prove the required safe state before touching the module.
  • Which configuration should be restored after replacing 6SE7031-7HG84-1JC1?
    Restore only the approved project, parameters, addresses and channel assignments retained from the installed system record; do not copy settings from a different catalog number.
  • How should engineers commission 6SE7031-7HG84-1JC1?
    Energize in the documented sequence, review device and host diagnostics, test the intended input, output or communication path under controlled conditions and retain the results.
  • Can 6SE7031-7HG84-1JC1 be replaced by a visually similar module?
    A substitute requires an explicit manufacturer-supported match for the complete 6SE7031-7HG84-1JC1 catalog identity, host platform, interface, ratings and configuration.
  • What maintenance evidence should be retained for 6SE7031-7HG84-1JC1?
    Keep the as-found connection record, installed position, software or parameter revision, diagnostic state and signed functional-test result.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.