Technical specifications for 6SE7031-7HG84-1JC1
-
Manufacturer:Siemens
-
Product Category:Servo Drives
-
Spare Part Number:6SE7031-7HG84-1JC1
-
Estimated shipping dimensions:57.5x30x3cm
-
Weight:0.72 kg
-
Tariff Code:8537101190
-
Counliy of origin:Germany
-
Module designation:IGD5
-
Equipment class:Inverter gating module
-
AC device voltage:660-690 V 3 AC
-
AC frequency:50/60 Hz
-
DC-link voltage:890-930 V DC
-
Device current:171 A
-
Successor article:6SE7031-7HG84-1JC2
Information
- Controls the inverter switching devices through the IGD5 interface
- Matches 660-690 V three-phase device hardware
- Supports a 890-930 V DC-link power section
- Provides the predecessor configuration for the JC2 replacement article
6SE7031-7HG84-1JC1 is installed with compatible 171 A SIMOVERT MASTERDRIVES power section, installed gate-drive harness, matching control electronics, approved converter commissioning record.
Engineered applications include High-voltage inverter power-section service, Masterdrives cabinet restoration, Gate-drive signal-path verification, Controlled JC1-to-JC2 replacement planning.
Important Notice: Isolate and discharge the DC link, verify zero energy, record every gate-drive connector and power-section position, then prove pulse blocking and controlled inverter response before enabling the motor.
Apter Power 6SE7031-7HG84-1JC1 Manuals and Guides
Apter Power 6SE7031-7HG84-1JC1 Product Technical Reference PDF6SE7031-7HG84-1JC1 Engineering Installation and Verification WorkbookThe first document presents model-specific technical identity and engineering data. The second provides a separate installation, connection and commissioning workflow.
High-voltage inverter power-section service
6SE7031-7HG84-1JC1 supports this documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware engineering task.
Masterdrives cabinet restoration
6SE7031-7HG84-1JC1 supports this documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware engineering task.
Gate-drive signal-path verification
6SE7031-7HG84-1JC1 supports this documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware engineering task.
Controlled JC1-to-JC2 replacement planning
6SE7031-7HG84-1JC1 supports this documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware engineering task.
Verify the complete 6SE7031-7HG84-1JC1 marking and its documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware position before field work.
Place the connected equipment in the approved maintenance state before removing 6SE7031-7HG84-1JC1.
Isolate every applicable power, signal and stored-energy source, then prove a safe state at 6SE7031-7HG84-1JC1.
Record the installed connectors, terminals, jumpers and channel or node assignments before disconnection.
Use ESD controls and protect keyed interfaces, edge connectors and exposed electronic assemblies.
Restore only the approved SIMOVERT MASTERDRIVES 660-690 V inverter hardware hardware arrangement and configuration after replacement.
Energize 6SE7031-7HG84-1JC1 in the documented sequence and review local, host and network diagnostics.
Prove the intended controlled function and retain the final acceptance record before production release.
Technical notes
FAQ View All FAQ
-
What system function does 6SE7031-7HG84-1JC1 provide?6SE7031-7HG84-1JC1 is the simovert masterdrives igd5 inverter gating module used in the documented SIMOVERT MASTERDRIVES 660-690 V inverter hardware arrangement. It generates the documented inverter gate-drive function for a 171 A SIMOVERT MASTERDRIVES power section.
-
Which host hardware must be checked before installing 6SE7031-7HG84-1JC1?Confirm the exact SIMOVERT MASTERDRIVES 660-690 V inverter hardware host, assigned position, mating connectors and companion hardware against the controlling manufacturer record for 6SE7031-7HG84-1JC1.
-
What wiring or connector record is required before replacing 6SE7031-7HG84-1JC1?Record every connector identifier, terminal, conductor, polarity, shield, jumper and channel or node assignment before removal.
-
How should power be isolated for 6SE7031-7HG84-1JC1?Follow the equipment-specific isolation procedure, remove applicable control and field energy, discharge stored energy and prove the required safe state before touching the module.
-
Which configuration should be restored after replacing 6SE7031-7HG84-1JC1?Restore only the approved project, parameters, addresses and channel assignments retained from the installed system record; do not copy settings from a different catalog number.
-
How should engineers commission 6SE7031-7HG84-1JC1?Energize in the documented sequence, review device and host diagnostics, test the intended input, output or communication path under controlled conditions and retain the results.
-
Can 6SE7031-7HG84-1JC1 be replaced by a visually similar module?A substitute requires an explicit manufacturer-supported match for the complete 6SE7031-7HG84-1JC1 catalog identity, host platform, interface, ratings and configuration.
-
What maintenance evidence should be retained for 6SE7031-7HG84-1JC1?Keep the as-found connection record, installed position, software or parameter revision, diagnostic state and signed functional-test result.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.