Product Describe:

Siemens 6ED1052-2FB08-0BA2 provides eight digital inputs and four relay outputs in a LOGO! 230RCEo logic module without an integral display. Its supply options include 115/230 V AC or DC.

Ask our team:

Get a quick price for: 6ED1052-2FB08-0BA2
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 6ED1052-2FB08-0BA2

Technical specifications for 6ED1052-2FB08-0BA2

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6ED1052-2FB08-0BA2
  • Estimated shipping dimensions:
    9x7.1x6cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Digital inputs:
    8
  • Relay outputs:
    4
  • Program capacity:
    400 function blocks
  • Nominal AC supply:
    115 / 230 V AC
  • DC supply range:
    100-253 V DC
  • AC frequency:
    47-63 Hz
  • Resistive contact load:
    10 A maximum
  • Inductive contact load:
    3 A maximum
  • Clock power reserve:
    480 h
  • Operating temperature:
    -20 to +55 °C; non-condensing
  • Engineering software:
    LOGO! Soft Comfort V8.4 or later
  • Network interface:
    Ethernet

Information

Information

Overview Manuals Common Applications Product Precautions
Siemens 6ED1052-2FB08-0BA2 combines local switching logic with network access for compact automation tasks that do not require a display on the controller.
  • Stores a control program of up to 400 function blocks.
  • Provides an Ethernet connection and an integrated web server.
  • Supports data logging and user-defined web pages.
  • Includes cloud connectivity and MQTT in the LOGO! 8.4 platform.

A standard microSD card supports the memory workflow, while LOGO! Soft Comfort V8.4 or later provides the engineering environment. Earlier projects remain executable, allowing existing logic to be carried forward after the application has been checked.

Important Notice: Check the response of the automatic sequence to a supply interruption before handing control back to the operator.

Siemens 6ED1052-2FB08-0BA2 Manuals & Downloads
Siemens 6ED1052-2FB08-0BA2 Manufacturer Technical Reference — Excerpt (PDF)Siemens 6ED1052-2FB08-0BA2 Installation & Commissioning Guide (PDF)

The technical reference and field guide cover complementary aspects of this product. Select the document for the task being performed.

Timed switching
Use timer and logic blocks for scheduled lighting or ventilation sequences.
Machine auxiliaries
Combine discrete permissives and relay-controlled auxiliary loads.
Local web visualization
Present application values through user-defined pages on the integrated server.
Data collection
Record operating variables and exchange application data over MQTT.
Installation and service checks for Siemens 6ED1052-2FB08-0BA2.
1
Isolate the module supply and independently powered relay circuits before wiring.
2
Use the supply variant and voltage indicated for this 230RCEo model.
3
Fit external fusing because the relay outputs have no internal short-circuit protection.
4
Keep resistive switching loads within the 10 A contact limit.
5
Limit inductive contact loading to 3 A and evaluate the load switching characteristics.
6
Operate only within -20 to +55 °C without condensation.
7
Use LOGO! Soft Comfort V8.4 or later when preparing the project.
8
Test each input, relay action and required network function before enabling automatic operation.

Technical notes

Technical notes

Check relay-load type before assigning circuit protection. A controller supply isolation point may leave externally fed relay contacts energized.

FAQS

  • Can Siemens 6ED1052-2FB08-0BA2 switch a motor load at the same current as a heater?
    No. The relay contact limit is 3 A for inductive loads and 10 A for resistive loads, so the load type changes the permissible current.
  • Why do relay circuits on Siemens 6ED1052-2FB08-0BA2 need separate fuses?
    The relay outputs do not include short-circuit protection, so external fusing is required for the connected circuits.
  • How long can the clock in Siemens 6ED1052-2FB08-0BA2 retain its time after supply loss?
    The time-switching clock has a power reserve of 480 hours.
  • Does Siemens 6ED1052-2FB08-0BA2 need a local screen for web-based visualization?
    No. This display-free module includes a web server and supports user-defined web pages accessed over Ethernet.
  • Which software version can engineer Siemens 6ED1052-2FB08-0BA2?
    LOGO! Soft Comfort V8.4 or later is required; projects from earlier versions remain executable.
  • What temperature conditions suit Siemens 6ED1052-2FB08-0BA2?
    The operating range is -20 to +55 °C in non-condensing conditions.
  • Is MQTT available on Siemens 6ED1052-2FB08-0BA2?
    Yes. MQTT and cloud connectivity are included in the LOGO! 8.4 basic unit.
  • Does the 400-block capacity of Siemens 6ED1052-2FB08-0BA2 provide 400 physical inputs or outputs?
    No. The 400 function blocks are program resources. The basic unit has eight physical digital inputs and four relay outputs; the block count does not increase those terminal counts.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.