Technical specifications for 6DD1661-0AE0
-
Manufacturer:Siemens
-
Product Category:DCS Systems
-
Spare Part Number:6DD1661-0AE0
-
Weight:0.6 kg
-
Tariff Code:8537101190
-
Product series:SIMATIC TDC
-
Module designation:CP5100
-
Network connection:1 × RJ45 Industrial Ethernet
-
Network rate:10 / 100 Mbit/s, automatic detection
-
Protocols:TCP/IP and UDP
-
Application scope:Configured process-data and visualization communication
-
Applicable rack slots:18 to 21 in the specified TDC configuration
-
Channel modes:Handshake, Refresh, Multiple and Select
-
Maximum channels:256; limited by data size, access mode and available memory
-
Data-interface RAM:254 KB
-
Receive telegram limit:55,759 bytes
-
Send telegram limit:65,535 bytes
Information
- The exact CP5100 identity must be retained when matching an existing system; protocol functions of a later communications-module version are separate.
Product series: SIMATIC TDC
Module designation: CP5100
CP5100 exchanges process data with configured Ethernet peers and supports WinCC process-data or message visualization. In the applicable TDC rack configuration it occupies slots 18 to 21, allowing up to four modules; its coding-switch setting must match the selected slot. The @TCPIP central block initializes and monitors the module, while CTV and CRV blocks provide the configured sending and receiving functions.
Handshake, Refresh, Multiple and Select channel modes support different data-transfer behavior. Refresh and Multiple can overwrite older data; Handshake and Select do not. Up to 256 channels are possible, but the achievable count depends on payload size, access mode and the available 254 KB data-interface RAM. Telegram length is limited to 55,759 bytes for receiving and 65,535 bytes for sending. Coordinate addresses and ports, monitor important data at application level and validate the actual peer exchange after service.
-
Siemens 6DD1661-0AE0 technical reference
Original Siemens technical excerpt - PDF, 8 pages. Product-specific technical information and applicable configuration details. -
Siemens 6DD1661-0AE0 installation guide
Prepared by Apter Power - PDF, 5 pages. Model identification, interface checks, configuration review and commissioning verification.
Application scope: Facts apply to the CP5100 execution. Later CP51M1 protocol features and application examples do not automatically extend this module capability.
-
Controller process data
Exchange configured data with another CP5100 or a compatible SIMATIC Industrial Ethernet peer. -
WinCC process displays
Supply the configured process values to the visualization application and validate its data mapping. -
WinCC message handling
Transfer engineered message information using the matching communication configuration and application. -
Process-computer integration
Exchange data with a compatible third-party peer using coordinated protocol, ports and telegram layout.
Match 6DD1661-0AE0 and the CP5100 execution; preserve the installed hardware and configuration identity.
Coordinate the IP address, subnet, router and application ports with the existing Industrial Ethernet network.
Retain the configured communication blocks, peer identity and telegram data layout.
Verify process data or WinCC display/message behavior at both ends after restoration.
Use the applicable isolation and electrostatic-discharge controls. Preserve connectors, identification and mechanical retention during handling.
Apply the approved site acceptance procedure and compare actual behavior with the recorded system configuration before returning equipment to service.
Alternative Names
Technical notes
System relationship: Coordinate the IP address, subnet, router and application ports with the existing Industrial Ethernet network.
Applicability: Facts apply to the CP5100 execution. Later CP51M1 protocol features and application examples do not automatically extend this module capability.
Technical reference: Siemens 6DD1661-0AE0 product information; SIMATIC TDC User Guide; System and Communication Configuring D7-SYS, A5E01115023-04, 07/2009.
FAQ View All FAQ
-
Which communications module is 6DD1661-0AE0?It is the SIMATIC TDC CP5100 Industrial Ethernet module.
-
Which network connector does 6DD1661-0AE0 use?It has one RJ45 Industrial Ethernet connection.
-
What link rates does 6DD1661-0AE0 support?It automatically detects 10 or 100 Mbit/s network operation.
-
Which protocols are specified for 6DD1661-0AE0?TCP/IP and UDP are the specified protocol options.
-
Which rack slots are specified for 6DD1661-0AE0?The applicable TDC configuration permits slots 18 to 21, with the module coding switches matched to its selected slot.
-
How many channels can 6DD1661-0AE0 support?Up to 256; the actual count depends on payload size, access mode and the 254 KB data-interface RAM.
-
What telegram limits apply to 6DD1661-0AE0?Maximum lengths are 55,759 bytes for receiving and 65,535 bytes for sending.
-
How do the channel modes on 6DD1661-0AE0 differ?Refresh and Multiple permit older data to be overwritten; Handshake and Select do not. Choose the protocol and application-level monitoring accordingly.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.