140CPU43412A

Modicon Quantum 80486 Processor Module
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Schneider Electric 140CPU43412A is a Modicon Quantum processor module with an 80486-class 66 MHz processor and 896 kB RAM. It provides two Modbus ports and one Modbus Plus interface for the documented Quantum controller architecture.

Ask our team:

Get a quick price for: 140CPU43412A
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 140CPU43412A

Technical specifications for 140CPU43412A

  • Manufacturer:
    Schneider Electric
  • Product Category:
    PLC Systems
  • Spare Part Number:
    140CPU43412A
  • Estimated shipping dimensions:
    4x10.6x25cm
  • Weight:
    0.46 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    France
  • Product designation:
    Modicon Quantum processor module
  • Processor class:
    80486
  • Processor clock:
    66 MHz
  • RAM capacity:
    896 kB
  • Programming environments:
    ProWORX32 and Concept
  • Modbus ports:
    2
  • Modbus Plus interfaces:
    1
  • Controller platform:
    Modicon Quantum
  • Key-switch function:
    Controller operating and memory-protection control
  • Lifecycle status:
    Discontinued product
  • Official replacement:
    BMEP582040 Modicon M580 processor

Information

Information

Overview Manuals Common Applications Product Precautions
Schneider Electric 140CPU43412A provides program execution and Modbus or Modbus Plus coordination in a documented legacy Modicon Quantum controller in a documented Modicon Quantum installation.
  • 80486-class 66 MHz processor
  • 896 kB RAM
  • Two Modbus ports
  • One Modbus Plus interface

The component remains matched to its documented cabinet position, power source, interfaces and approved engineering configuration. Commissioning restores that architecture and verifies the affected control or communication function under controlled conditions.

Important Notice: Confirm 140CPU43412A, its exact Modicon Quantum host, power source, installed position, interfaces, configuration, diagnostics and controlled acceptance evidence before release.

Schneider Electric 140CPU43412A Manuals & Downloads

These documents are different: the first consolidates exact product and system data; the second provides model-specific installation checks, commissioning steps and acceptance guidance.

Legacy Quantum controller
Executes the approved Concept or ProWORX32 application in the documented rack.
Modbus device coordination
Communicates with assigned serial devices through the two controller ports.
Modbus Plus networking
Exchanges data with the validated Modbus Plus nodes and addressing plan.
CPU replacement commissioning
Restores the saved application, port settings and controlled process response.
Read the applicable Schneider Electric installation instructions before work. Verify 140CPU43412A, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete 140CPU43412A marking and the documented Modicon Quantum 80486 Processor Module execution.
2
Place the machine, controller and affected process in the approved maintenance state.
3
Isolate all hazardous energy and prove the safe state before disconnecting hardware.
4
Record the installed position, every terminal or port, and the active engineering configuration.
5
Verify the exact electrical, interface and environmental limits in the manufacturer evidence.
6
Restore protective earth, shielding, wiring, communications and the approved project or parameters.
7
Energize under control and review all device, rack, network and process diagnostics.
8
Complete a controlled functional test of program execution and Modbus or Modbus Plus coordination in a documented legacy Modicon Quantum controller before release.

Technical notes

Technical notes

Install 140CPU43412A only in the documented Modicon Quantum position and preserve its exact wiring, interfaces and configuration. After controlled energization, verify diagnostics and program execution and Modbus or Modbus Plus coordination in a documented legacy Modicon Quantum controller before service release.

FAQS

  • Which processor and clock are documented for Schneider Electric 140CPU43412A?
    140CPU43412A uses an 80486-class processor operating at 66 MHz.
  • How much RAM is identified for 140CPU43412A?
    The current Schneider Electric exact-product record specifies 896 kB RAM.
  • Which programming environments are associated with 140CPU43412A?
    The official product record identifies ProWORX32 and Concept for this Quantum processor.
  • How many Modbus ports are available on 140CPU43412A?
    The processor provides two Modbus ports.
  • How many Modbus Plus interfaces does 140CPU43412A provide?
    It provides one Modbus Plus interface.
  • What must be backed up before replacing 140CPU43412A?
    Back up the approved application, communication settings, memory state and controller configuration before removal.
  • Which official migration processor replaces 140CPU43412A?
    Schneider Electric lists the Modicon M580 BMEP582040 processor as the recommended replacement.
  • What proves a replacement 140CPU43412A is ready for service?
    Confirm application restoration, Modbus and Modbus Plus communication, diagnostics and controlled process response.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.