Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 140CPS12420C
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 140CPS12420C

  • Manufacturer:
    Schneider Electric
  • Product Category:
    PLC Systems
  • Spare Part Number:
    140CPS12420C
  • Estimated shipping dimensions:
    4x10.5x25cm
  • Weight:
    0.64 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    France
  • Product range:
    Modicon Quantum automation platform
  • Product type:
    Redundant power supply module
  • Input ranges:
    93–138 V AC; 170–276 V AC
  • Input frequency:
    47–63 Hz
  • Input current:
    1.1 A at 115 V; 0.6 A at 230 V
  • Inrush current:
    38 A at 115 V; 19 A at 230 V
  • Associated fuse:
    2 A slow-blow
  • Output voltage:
    5.1 V DC
  • Standalone output:
    11 A at 60 °C
  • Redundant output:
    10 A at 60 °C
  • Alarm contact:
    Normally closed; 6 A at 220 V AC or 5 A at 30 V DC
  • Alarm drop-out:
    Input below 8 V DC
  • Protection:
    Internal output overvoltage and overload protection
  • Indicator:
    Green PWR OK LED
  • Operating temperature:
    0–60 °C

Information

Overview Manuals Common Applications Product Precautions
Schneider Electric 140CPS12420C converts a 115 V or 230 V AC source to the Quantum backplane supply and provides a normally closed fault-alarm contact.
  • 115/230 V AC input
  • 5.1 V DC backplane output
  • 11 A standalone rating
  • 10 A redundant-pair capacity

Use Schneider Electric 140CPS12420C only with the documented rack, field interface and approved commissioning record for the installed application.

Important Notice: Confirm the complete 140CPS12420C identifier, companion hardware and wiring condition; do not substitute a nearby code without an engineering review.

Schneider Electric 140CPS12420C Manuals & Downloads
Schneider Electric 140CPS12420C Technical Reference (PDF)Schneider Electric 140CPS12420C Installation & Commissioning Guide (PDF)

The Technical Reference consolidates exact-model technical data and engineering boundaries; the Installation & Commissioning Guide organizes identity control, isolation, interface checks, functional testing and acceptance records.

Quantum redundant rack
Maintains backplane power with the documented redundant supply pairing.
AC-powered local rack
Converts 115 V or 230 V AC to the Quantum 5.1 V backplane bus.
Power-fault annunciation
Uses the normally closed alarm contact in the site monitoring circuit.
Power-supply renewal
Restores fuse, terminal, load-sharing and PWR OK checks for the same model.
Apply these controls specifically to Schneider Electric 140CPS12420C before isolation, replacement, reconnection and final release.
1
Isolate both AC feeds and prove the safe state before removing either redundant supply.
2
Record the live and neutral conductors, protective earth, alarm contact and rack position.
3
Use the documented 2 A slow-blow external fuse arrangement.
4
Verify the installed AC source lies within the selected input range before energization.
5
Confirm total rack load does not exceed the applicable standalone or redundant capacity.
6
Preserve the normally closed alarm-contact logic and its external circuit rating.
7
Energize the pair in a controlled sequence and observe both PWR OK indications.
8
Prove loss-of-one-supply alarm response and continued rack operation before release.

Alternative Names

140CPS12420C

Technical notes

Record the complete model identity, installed system position, companion hardware, field wiring and configuration before service. Use the exact-model limits and acceptance checks shown in the manuals for restoration.

FAQ View All FAQ

  • What input supplies are supported by Schneider Electric 140CPS12420C?
    It accepts 93–138 V AC or 170–276 V AC at 47–63 Hz.
  • What output does Schneider Electric 140CPS12420C provide to the Quantum rack?
    It supplies 5.1 V DC to the backplane.
  • What is the standalone current rating of Schneider Electric 140CPS12420C?
    The standalone rating is 11 A at 60 °C.
  • What is the redundant-pair capacity of Schneider Electric 140CPS12420C?
    A matched redundant pair provides a documented total load capacity of 10 A at 60 °C.
  • Which fuse is specified for Schneider Electric 140CPS12420C?
    Use a 2 A slow-blow external fuse in the documented supply arrangement.
  • What alarm contact is available on Schneider Electric 140CPS12420C?
    Terminals 1 and 2 provide a normally closed contact rated 6 A at 220 V AC or 5 A at 30 V DC.
  • How should Schneider Electric 140CPS12420C redundancy be tested?
    With the rack in a controlled state, remove one feed at a time and verify alarm response, remaining PWR OK status and uninterrupted rack power.
  • What must be checked before replacing Schneider Electric 140CPS12420C?
    Record both feeds, fuse protection, alarm wiring, rack load, companion supply model and backplane position.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.