The T9832 is an ICS Triplex AADvance Dual Analogue Input Termination Assembly for the AADvance system.
- AADvance Dual Analogue Input Termination Assembly
- Terminates 16 analogue field loops
- Dual-module analogue input architecture
- Use with T9432 modules and T9300 I/O base
It terminates sixteen analogue field loops for a dual AADvance analogue-input module arrangement. It handles analogue transmitter wiring and returns for dual-module input architecture and operates with T9432 analogue input modules, T9300 I/O base unit and the engineered dual-channel wiring scheme. Verify the exact hardware revision, matched termination and controlled application records before commissioning.
Important Notice: Use the complete T9832 code and verify the physical nameplate, current ICS Triplex / Rockwell Automation documentation, field wiring, project, and compatible system hardware before installation or replacement.
Apter Power T9832 Manuals and Guides
Important Notice: These are two separate Apter Power documents prepared from the manufacturer-published ICS Triplex / Rockwell Automation information named in each document. Confirm the physical nameplate, current ICS Triplex / Rockwell Automation documents, and host-system requirements before installation or replacement.
Dual analogue transmitter inputs
Uses the T9832 aadvance dual analogue input termination assembly in a model-appropriate AADvance control or protection function.
SIS pressure measurement
Handles system status and diagnostics under the official engineering limits.
Temperature transmitter loops
Uses the T9832 aadvance dual analogue input termination assembly in a model-appropriate AADvance control or protection function.
Flow protection channels
Handles system status and diagnostics under the official engineering limits.
Read Rockwell Automation ICSTT-RM448N-EN-P and the applicable system installation instructions before use. Verify the physical nameplate, revision, slot and matched termination hardware.
1
Verify the exact model, hardware revision, firmware and nameplate before substitution.
2
Install only with T9432 analogue input modules, T9300 I/O base unit and the engineered dual-channel wiring scheme; do not mix unmatched termination or base hardware.
3
De-energize or follow the approved live-insertion procedure and site safety plan before removal.
4
Preserve module keying, slot assignment, wiring polarity, shields, grounding and field power limits.
5
Complete application download, diagnostics, proof testing and functional acceptance before return to service.