Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

TC-OAV081

eight-channel non-isolated analog output module
In Stock
Ships by Thursday, September 17
Fast Shipping Available

Product Describe:

Honeywell TC-OAV081 is an
eight-channel non-isolated analog output module
supporting voltage and current output applications.

Ask our team:

Get a quick price for: TC-OAV081
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for TC-OAV081

Technical specifications for TC-OAV081

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    TC-OAV081
  • Estimated shipping dimensions:
    3.5x14x14.5cm
  • Weight:
    0.24 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Output channels:
    8
  • Voltage range:
    +/-10.4 V
  • Current range:
    0-21 mA
  • Voltage resolution:
    320 microvolts per count
  • Current resolution:
    650 nA per count
  • Voltage load:
    >2000 ohms
  • Current load:
    0-750 ohms
  • All-channel update:
    25 ms
  • Power dissipation:
    6.9 W maximum
  • Terminal block:
    TC-TBNH, 20-position

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell TC-OAV081 is an analog-output module for an Experion control-system field interface.
  • Experion I/O integration
  • Analog command delivery
  • Field-interface support
  • Controller-project configuration

TC-OAV081 transfers configured analog-output commands from the controller to the associated field circuits. Confirm the selected output range, channel-to-device mapping, loop continuity, field wiring and output scaling, then verify the commanded response at each connected device.

Important Notice: Confirm whether the required terminal base, I/O adapter, field wiring, connector set and controller configuration for TC-OAV081 are included in the quotation or stock description.

Apter Power TC-OAV081 Manuals and Guides

Important Notice: These are two separate Apter Power documents prepared from product-specific Honeywell technical information. Confirm the physical nameplate, current Honeywell documents and installed-system requirements before configuration or installation. They do not replace Honeywell manuals.

TC-OAV081 installed-base replacement
Supports like-for-like maintenance of the documented eight-channel non-isolated analog output module.
TC-OAV081 compatibility review
Checks the host hardware, slot or mounting position, companion assembly, cable and revision before replacement.
TC-OAV081 installation planning
Defines the required isolation, ESD, terminal, wiring and configuration checks before field work.
TC-OAV081 commissioning
Supports controlled power, channel, communication, diagnostic and process-response checks after installation.
Read the applicable Honeywell instructions before work. Verify model TC-OAV081, part number TC-OAV081 and the installed-system configuration.
1
Verify model TC-OAV081 and part number TC-OAV081 on the physical label before use.
2
Use TC-OAV081 with the exact Honeywell host, companion hardware, terminal assembly and field wiring specified for the installed system.
3
Match every TC-OAV081 connector, terminal, cable and companion assembly before moving field wiring.
4
Back up the applicable controller, node, I/O or communication configuration before replacing TC-OAV081.
5
Isolate energy before handling TC-OAV081 unless the applicable hardware procedure explicitly permits energized service.
6
Follow ESD controls and protect TC-OAV081 connectors and printed-circuit assemblies during handling.
7
Do not transfer channel, voltage, current, terminal or firmware values from a similar model to TC-OAV081.
8
After installing TC-OAV081, complete the relevant power, channel, link, diagnostic, alarm and fail-state checks.

Alternative Names

Alternative Names

TC-OAV081

Technical notes

Technical notes

Use TC-OAV081 with the exact Honeywell host, companion hardware, terminal assembly and field wiring specified for the installed system.

FAQS

  • Which output service is TC-OAV081 intended for?
    TC-OAV081 is intended for eight-channel non-isolated analog output module service with the channel and signal limits listed on this page.
  • How should an output load be matched to TC-OAV081?
    Confirm the load voltage, current, resistance, field supply and protection are within the documented limits for TC-OAV081.
  • What commissioning test is appropriate for TC-OAV081?
    Exercise one TC-OAV081 channel at a time under an approved test procedure and verify the field device, feedback and fail-state response.
  • What output channels value applies to TC-OAV081?
    For TC-OAV081, the listed output channels value is 8. Confirm the same marking and configuration on the installed unit before work.
  • What voltage range value applies to TC-OAV081?
    For TC-OAV081, the listed voltage range value is +/-10.4 V. Confirm the same marking and configuration on the installed unit before work.
  • What current range value applies to TC-OAV081?
    For TC-OAV081, the listed current range value is 0-21 mA. Confirm the same marking and configuration on the installed unit before work.
  • What voltage resolution value applies to TC-OAV081?
    For TC-OAV081, the listed voltage resolution value is 320 microvolts per count. Confirm the same marking and configuration on the installed unit before work.
  • What current resolution value applies to TC-OAV081?
    For TC-OAV081, the listed current resolution value is 650 nA per count. Confirm the same marking and configuration on the installed unit before work.
  • Is TC-OAV081 compatible with every Honeywell rack or chassis?
    No. Match TC-OAV081 to the exact Honeywell host, rack or chassis, slot, companion hardware and project revision used by the installed system.
  • What installation checks are required for TC-OAV081?
    Confirm isolation, ESD controls, slot or mounting position, connector orientation, terminal hardware, cable code and field wiring before installation.
  • Which fault information helps troubleshoot TC-OAV081?
    Record TC-OAV081 indicators, diagnostics, affected channels, field measurements, wiring checks, companion hardware and the sequence that produced the fault.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.