TC-IDA161

Sixteen-Point 120 Vac Digital Input Module
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

Honeywell TC-IDA161 is a Sixteen-Point 120 Vac Digital Input Module. It converts AC field states into controller input indications.

Ask our team:

Get a quick price for: TC-IDA161
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for TC-IDA161

Technical specifications for TC-IDA161

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    TC-IDA161
  • Estimated shipping dimensions:
    3.5x14x14.5cm
  • Weight:
    0.24 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Input points:
    16
  • Input voltage:
    120 Vac
  • Signal type:
    AC digital input

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell TC-IDA161 is a 16-point 120 Vac digital input module for C200 ControlNet I/O. It converts AC field states into controller input indications.
  • Acquires powered AC input states
  • Transfers discrete status through the C200 I/O network
  • Fits a ControlNet I/O chassis
  • Monitors powered field contacts

TC-IDA161 installs with C200 I/O chassis, ControlNet adapter, 120 Vac input supply, Powered status contacts in an engineered Experion C200 ControlNet I/O configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this sixteen-point 120 vac digital input module.

Important Notice: Confirm the complete TC-IDA161 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power TC-IDA161 Manuals and Guides
Apter Power TC-IDA161 Product Technical Reference PDFHoneywell TC-IDA161 Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Motor starter feedbackAcquires powered AC input states
AC limit-switch monitoringTransfers discrete status through the C200 I/O network
Breaker status inputsFits a ControlNet I/O chassis
Package equipment alarmsMonitors powered field contacts
Read the applicable Honeywell installation instructions before work. Verify TC-IDA161 and the installed Experion C200 ControlNet I/O configuration.
1Verify the complete TC-IDA161 marking and the assigned Experion C200 ControlNet I/O position before field work.
2Isolate the applicable power, network and field energy before disconnecting TC-IDA161.
3Use ESD controls and protect the keyed connectors of TC-IDA161 during handling.
4Record the installed wiring, jumpers, node or channel assignment before replacement.
5Confirm C200 I/O chassis and ControlNet adapter against the approved system configuration.
6Restore TC-IDA161 under controlled conditions and review the product-specific diagnostics.
7Complete a functional test for motor starter feedback before production release.

Technical notes

Technical notes

Isolate the field source and verify commons and channel identity before wiring, then prove each input indication at the controller.

FAQS

  • What as-found wiring record is required for the TC-IDA161 Sixteen-Point 120 Vac Digital Input Module in Motor starter feedback?
    Record terminal identity, polarity, shields, jumpers, cable tags and the as-found diagnostic state for TC-IDA161.
  • Which Experion C200 ControlNet I/O configuration must be checked when commissioning the TC-IDA161 Sixteen-Point 120 Vac Digital Input Module?
    Verify the assigned channel, slot, node or interface and compare it with the approved Experion C200 ControlNet I/O configuration before enabling TC-IDA161.
  • How can the TC-IDA161 Sixteen-Point 120 Vac Digital Input Module be function-tested for AC limit-switch monitoring without disturbing the process?
    Use a controlled stimulus or limited command, observe the expected system indication and confirm the intended response while normal interlocks remain effective.
  • Which diagnostics should be reviewed if the TC-IDA161 Sixteen-Point 120 Vac Digital Input Module stops performing its assigned system function?
    Check seating, the matched C200 I/O chassis, the condition of ControlNet adapter and the model-specific diagnostics before replacing more hardware.
  • Can the TC-IDA161 Sixteen-Point 120 Vac Digital Input Module used for Breaker status inputs be transferred to another Experion C200 ControlNet I/O position without engineering review?
    No. Confirm the hardware execution, connector scheme and approved Experion C200 ControlNet I/O configuration before transferring TC-IDA161 to a different duty.
  • What evidence should be retained after the TC-IDA161 Sixteen-Point 120 Vac Digital Input Module returns to Package equipment alarms service?
    Retain the physical identification, as-left wiring or configuration, final diagnostics and controlled functional-test result for TC-IDA161.
  • Which C200 I/O chassis identity must be verified before fitting the TC-IDA161 Sixteen-Point 120 Vac Digital Input Module?
    Match the complete TC-IDA161 marking, assigned Experion C200 ControlNet I/O position and installed C200 I/O chassis before work.
  • How should ControlNet adapter be isolated before disconnecting the TC-IDA161 Sixteen-Point 120 Vac Digital Input Module?
    Place the affected process in its approved maintenance state, isolate applicable energy and prove ControlNet adapter safe before disconnection.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.