Speak to a sourcing specialist
sales13@apterpower.com

FC-SDOL-0424

High-Current Safe Digital Output Module
In Stock
Ships by Friday, November 6
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Honeywell FC-SDOL-0424 is a four-channel high-current safe digital output module for Safety Manager I/O. It switches 24 V DC safety-related final elements while monitoring output current and protected load behavior.
Get a quick price for FC-SDOL-0424
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for FC-SDOL-0424

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    FC-SDOL-0424
  • Estimated shipping dimensions:
    2,2x19x12.7cm
  • Weight:
    0.12 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Output channels:
    4
  • Output type:
    24 V DC solid-state source
  • Output protection:
    Short-circuit proof
  • Maximum channel current:
    1 A
  • Maximum total current:
    3.6 A
  • Maximum load inductance:
    0.5 H
  • Maximum load capacitance:
    1 uF
  • Voltage drop:
    <1.3 V at 1 A
  • Off-state current:
    <0.1 mA
  • Current-sense voltage drop:
    <1 V at 1 A
  • Overload threshold:
    >10 Ohm
  • Lamp threshold:
    >20 Ohm
  • 5 V DC current:
    15 mA
  • 24 V DC internal current:
    50 mA
  • 24 V DC external current:
    15 mA unloaded
  • Watchdog current:
    4 mA
  • Module size:
    4TE, 3HE (4HP, 3U)
  • Approvals:
    CE, TUV, UL, CSA, FM

Information

Overview Manuals Common Applications Product Precautions
Honeywell FC-SDOL-0424 is a high-current safe digital output module for Safety Manager I/O. It switches four protected 24 V DC output channels for demanding safety-related final elements.
  • Drives four high-current safe output channels
  • Supplies up to 1 A on an individual channel
  • Limits combined module output current to 3.6 A
  • Supports inductive loads up to the published 0.5 H limit

FC-SDOL-0424 is installed in the Safety Manager I/O chassis with internal and external 24 V DC supplies, validated safety logic and documented high-current final elements.

Its engineered duties include shutdown-solenoid actuation, safety-contactor control, inductive trip-load switching and like-for-like renewal of an approved high-current output position.

Important Notice: Confirm the complete FC-SDOL-0424 marking, assigned I/O position, load current, field supply and safe-state behavior before installation; after commissioning, retain the current-sense and final-element proof-test results.

Apter Power FC-SDOL-0424 Manuals and Guides

Apter Power FC-SDOL-0424 High-Current Safe Output Technical Reference PDFFC-SDOL-0424 Load, Wiring and Functional Acceptance Workbook PDF

The first document provides the model-specific technical and system reference. The second is a distinct field workbook for load review, installation, connection checks, commissioning and acceptance records.

Shutdown-solenoid actuation

Controls documented high-current 24 V DC trip solenoids in a Safety Manager shutdown function.

Safety-contactor control

Switches approved contactor coils while retaining the engineered safe-output assignment.

Inductive trip-load switching

Operates inductive safety loads within the published channel and module limits.

High-current output renewal

Replaces an installed FC-SDOL-0424 position while preserving project identity and proof-test evidence.

Read the applicable Honeywell Safety Manager instructions before work. Verify FC-SDOL-0424, both 24 V DC supplies and the installed high-current safe-output configuration.
1

Verify the complete FC-SDOL-0424 marking and its assigned four-channel high-current safe-output position before work.

2

Place the connected process and control strategy in the approved maintenance state.

3

Isolate the applicable cabinet supply and 24 V high-current output field energy before disconnecting conductors.

4

Record terminal numbers, channel assignments, polarity, shields and configured ranges before removal.

5

Use ESD controls and protect the backplane connector, terminal hardware and coated electronics.

6

Confirm the installed Safety Manager I/O chassis and carrier arrangement against the approved project.

7

Restore power in a controlled sequence and clear only diagnostics created by the maintenance activity.

8

Complete a current-sense and final-element proof test on every active channel and retain the measured result before returning the channel to automatic service.

Technical notes

Calculate the channel and total load currents, isolate both 24 V supplies, record safe-state behavior and prove current sensing and final-element action after installation.

FAQ View All FAQ

  • What exact Honeywell system position is intended for FC-SDOL-0424?
    FC-SDOL-0424 is assigned to the documented Honeywell Safety Manager role as high-current safe digital output module; confirm that role against the installed cabinet record.
  • Which field signal or controlled function is handled by FC-SDOL-0424?
    Its documented signal duty is four protected high-current 24 v dc safety-related source outputs. The controlling source lists output type as 24 V DC solid-state source.
  • Which companion hardware must be checked before installing FC-SDOL-0424?
    Match FC-SDOL-0424 with Safety Manager I/O chassis and 24 V DC external field supply; also retain the approved carrier, cable and project identity.
  • What electrical limit should an engineer verify before wiring FC-SDOL-0424?
    Verify the model-specific value for Maximum channel current: 1 A. Do not transfer a limit from another module revision.
  • How should the installed configuration be preserved when replacing FC-SDOL-0424?
    Record the as-found slot, connector, channel assignment and project revision, then restore only the approved Honeywell Safety Manager configuration.
  • Which isolation or handling check applies to FC-SDOL-0424?
    Apply the isolation and ESD sequence stated for FC-SDOL-0424; the source also identifies maximum load inductance as 0.5 H.
  • What diagnostic or commissioning evidence is required for FC-SDOL-0424?
    Complete the model-specific functional check for large shutdown-solenoid actuation, review host diagnostics and retain the final test result.
  • Can FC-SDOL-0424 be substituted for a visually similar Honeywell assembly?
    No automatic substitution is assumed. Compare the complete FC-SDOL-0424 marking, output channels, companion hardware, signal duty and approved system revision.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.