CC-GDIL01

Galvanically Isolated Digital Input Module
In Stock
Ships by Monday, September 21
Fast Shipping Available

Product Describe:

Honeywell CC-GDIL01 is a 32-channel galvanically isolated digital-input module for acquiring 24 Vdc field states in Series C systems.

Ask our team:

Get a quick price for: CC-GDIL01
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for CC-GDIL01

Technical specifications for CC-GDIL01

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    51306317-175
  • Estimated shipping dimensions:
    29.5x24x5.5cm
  • Weight:
    0.46 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Input channels:
    32
  • Input isolation:
    Galvanic
  • Signal type:
    Digital input
  • Input supply:
    24 Vdc field circuits
  • Module family:
    Series C

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell CC-GDIL01 is a 32-channel galvanically isolated digital-input module for acquiring 24 Vdc field states in Series C systems.
  • Acquires thirty-two discrete field states
  • Provides galvanic channel isolation
  • Filters field contact transitions
  • Reports digital-input diagnostics

CC-GDIL01 operates with Matched digital-input IOTA, 24 Vdc field supply, Series C carrier, Dry contacts or powered status devices.

Its engineered use includes Motor running feedback, Valve limit-switch inputs, Package-unit alarm contacts, Electrical switchgear status.

Important Notice: Confirm the complete CC-GDIL01 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power CC-GDIL01 Manuals and Guides
Apter Power CC-GDIL01 Product Technical Reference PDFHoneywell CC-GDIL01 Official Technical Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports installation, configuration and engineering verification for CC-GDIL01.
Motor running feedbackAcquires thirty-two discrete field states
Valve limit-switch inputsProvides galvanic channel isolation
Package-unit alarm contactsFilters field contact transitions
Electrical switchgear statusReports digital-input diagnostics
Read the applicable Honeywell instructions before work. Verify CC-GDIL01 and the installed Experion Series C I/O configuration.
1Verify the complete CC-GDIL01 marking and its assigned Experion Series C I/O position before work.
2Isolate the applicable power and field energy before disconnecting CC-GDIL01.
3Protect CC-GDIL01 connectors and electronic assemblies with approved ESD controls.
4Record the installed wiring, channel assignment and configuration before replacement.
5Match Matched digital-input IOTA and 24 Vdc field supply to the documented system arrangement.
6Commission CC-GDIL01 with controlled status, signal and diagnostic checks.
7Retain the final motor running feedback functional-test result in the maintenance record.

Technical notes

Technical notes

Verify input supply reference, field contact wetting arrangement and channel isolation before testing state changes from the process device.

FAQS

  • Does CC-GDIL01 match Matched digital-input IOTA in a Motor running feedback installation?
    Verify the complete CC-GDIL01 marking, the documented Experion Series C I/O position and the installed Matched digital-input IOTA before fitting the assembly.
  • How should CC-GDIL01 be wired when it must acquires thirty-two discrete field states?
    Isolate the circuit, identify every terminal and reproduce the approved polarity, shield and channel assignment for CC-GDIL01; then continuity-test the affected path.
  • Which Experion Series C I/O records should be captured before removing CC-GDIL01?
    Record the as-found wiring, installed position, active configuration and diagnostic state associated with CC-GDIL01 before disconnection.
  • What controlled test confirms that CC-GDIL01 can provides galvanic channel isolation?
    Apply the approved field or simulated stimulus, observe the Experion Series C I/O indication and confirm the intended response without bypassing the normal interlocks.
  • Which 24 Vdc field supply condition should be checked when CC-GDIL01 reports an abnormal state?
    Check the 24 Vdc field supply supply, seating and connection first, then compare channel diagnostics with the recorded CC-GDIL01 baseline.
  • Can CC-GDIL01 be moved directly into Valve limit-switch inputs without validating Dry contacts or powered status devices?
    No. Confirm the Dry contacts or powered status devices, revision, connection scheme and Experion Series C I/O configuration before transferring CC-GDIL01 to that duty.
  • What maintenance evidence is required after CC-GDIL01 is used for Package-unit alarm contacts?
    Retain the nameplate record, corrective action, final diagnostics and a controlled package-unit alarm contacts functional-test result for CC-GDIL01.
  • How should CC-GDIL01 be returned to service in Electrical switchgear status?
    Restore power under control, verify filters field contact transitions, exercise the intended signal path and release CC-GDIL01 only after the Experion Series C I/O remains in its approved operating state.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.