FC-SAI-1620M

Safe Analog Input Module
In Stock
Ships by Monday, September 21
Fast Shipping Available

Product Describe:

Honeywell FC-SAI-1620M is a Safe Analog Input Module for Safety Manager applications. It acquires and supervises documented analog field signals for safety-related processing.

Ask our team:

Get a quick price for: FC-SAI-1620M
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for FC-SAI-1620M

Technical specifications for FC-SAI-1620M

  • Manufacturer:
    Honeywell
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    FC-SAI-1620M
  • Estimated shipping dimensions:
    1,2x19x12.8cm
  • Weight:
    0.14 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Input channels:
    16
  • Input range:
    0 to 4.1 V
  • Input impedance:
    >1 MOhm
  • Maximum load capacitance:
    100 nF
  • A/D resolution:
    12 bit
  • ADC inaccuracy:
    +/-1 LSB
  • Module inaccuracy:
    <0.25%
  • Absolute maximum input:
    +/-36 V DC
  • Crosstalk:
    >60 dB
  • External readback range:
    0 to 4.1 V
  • External readback impedance:
    1 MOhm typical
  • 5 V DC current:
    35 mA
  • 24 V DC current:
    35 mA
  • Module size:
    4TE, 3HE (4HP, 3U)
  • Approvals:
    CE, TUV, UL, CSA, FM

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell FC-SAI-1620M is safe analog input module. It digitizes sixteen safety-related analog voltage inputs for monitoring and protective logic in a Safety Manager system.
  • Acquires sixteen safe analog input channels
  • Measures within the documented zero-to-4.1-volt range
  • Converts each channel with twelve-bit resolution
  • Provides external readback for controlled verification

FC-SAI-1620M operates with Safety Manager I/O chassis, conditioned analog safety transmitters, 24 V DC module supply, validated safety application.

Engineered applications include Analog trip-threshold monitoring, Safety transmitter acquisition, Process protection measurement, Safe analog-input renewal.

Important Notice: Record channel scaling and trip thresholds, isolate transmitter loops and prove input accuracy, readback and trip behavior under the approved safety test procedure.

Apter Power FC-SAI-1620M Manuals and Guides

Apter Power FC-SAI-1620M Product and System Technical Reference PDFApter Power FC-SAI-1620M Field Installation and Functional Acceptance Workbook PDF

The first document organizes model-specific identity, technical data and system context. The second provides a separate installation, connection, commissioning and acceptance workflow.

Analog trip-threshold monitoring

Collects conditioned analog values used by trip logic.

Safety transmitter acquisition

Monitors safety-related transmitters within the voltage range.

Process protection measurement

Feeds protective measurements into a validated application.

Safe analog-input renewal

Restores the input module while retaining scaling and proof-test records.

Read the applicable Honeywell instructions before work. Verify FC-SAI-1620M and the installed Honeywell Safety Manager configuration.
1

Verify the complete FC-SAI-1620M marking and its assigned sixteen-channel safe analog-input position before work.

2

Place the connected process and control strategy in the approved maintenance state.

3

Isolate the applicable cabinet supply and analog input field energy before disconnecting conductors.

4

Record terminal numbers, channel assignments, polarity, shields and configured ranges before removal.

5

Use ESD controls and protect the backplane connector, terminal hardware and coated electronics.

6

Confirm the installed Safety Manager I/O chassis and carrier arrangement against the approved project.

7

Restore power in a controlled sequence and clear only diagnostics created by the maintenance activity.

8

Complete multi-point scaling, readback and trip-response proof testing and retain the measured result before returning the channel to automatic service.

Technical notes

Technical notes

Install FC-SAI-1620M only in the documented Safety Manager slot and preserve every approved channel assignment, shield and loop connection. After configuration restoration, verify input scaling, diagnostics and the configured safety response under the approved test procedure.

FAQS

  • What exact Honeywell system position is intended for FC-SAI-1620M?
    FC-SAI-1620M is assigned to the documented Honeywell Safety Manager role as safe analog input module; confirm that role against the installed cabinet record.
  • Which field signal or controlled function is handled by FC-SAI-1620M?
    Its documented signal duty is sixteen 0 to 4.1 v safety-related analog-input signals. The controlling source lists input range as 0 to 4.1 V.
  • Which companion hardware must be checked before installing FC-SAI-1620M?
    Match FC-SAI-1620M with Safety Manager I/O chassis and conditioned analog safety transmitters; also retain the approved carrier, cable and project identity.
  • What electrical limit should an engineer verify before wiring FC-SAI-1620M?
    Verify the model-specific value for Maximum load capacitance: 100 nF. Do not transfer a limit from another module revision.
  • How should the installed configuration be preserved when replacing FC-SAI-1620M?
    Record the as-found slot, connector, channel assignment and project revision, then restore only the approved Honeywell Safety Manager configuration.
  • Which isolation or handling check applies to FC-SAI-1620M?
    Apply the isolation and ESD sequence stated for FC-SAI-1620M; the source also identifies adc inaccuracy as +/-1 LSB.
  • What diagnostic or commissioning evidence is required for FC-SAI-1620M?
    Complete the model-specific functional check for analog trip-threshold monitoring, review host diagnostics and retain the final test result.
  • Can FC-SAI-1620M be substituted for a visually similar Honeywell assembly?
    No automatic substitution is assumed. Compare the complete FC-SAI-1620M marking, input channels, companion hardware, signal duty and approved system revision.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.