Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

CC-TAOX01

Sixteen-Point Analog Output IOTA
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Honeywell CC-TAOX01 is a sixteen-point nonredundant Series-C analog output IOTA. It terminates a CC-PAOH01 or CC-PAOX01 output module and connects sixteen 4–20 mA commands to compatible field devices.

Ask our team:

Get a quick price for: CC-TAOX01
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for CC-TAOX01

Technical specifications for CC-TAOX01

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    51308351-175
  • Estimated shipping dimensions:
    14.6x12.1x6.8cm
  • Weight:
    0.24 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • IOTA type:
    Analog output; nonredundant
  • Channels:
    16
  • Physical size:
    6 in
  • Compatible modules:
    CC-PAOH01 and CC-PAOX01
  • Output range:
    4 to 20 mA
  • Output ripple:
    <100 mV peak-to-peak across 250 Ohm
  • Temperature drift:
    0.005% FS/degC
  • Readback accuracy:
    +/-4% FS
  • Current linearity:
    +/-0.05% FS nominal
  • Resolution:
    +/-0.05% FS
  • Calibrated accuracy:
    +/-0.35% FS at 25 degC
  • Direct-set range:
    0 mA or 2.9 to 21.1 mA
  • Maximum load:
    800 Ohm at 22 to 28 V DC supply
  • Terminal plugs:
    Two 16-pin; 51506273-216

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell CC-TAOX01 provides the field-termination base for a sixteen-point nonredundant Series-C analog-output installation.
  • Organizes field-loop conductors at the output IOTA
  • Pairs the installed electronics with a dedicated termination base
  • Supports current-command delivery to compatible final elements
  • Provides a controlled connection point for cabinet service

CC-TAOX01 is installed with a compatible CC-PAOH01 or CC-PAOX01 module, two sixteen-pin terminal plugs, an approved loop supply and 4–20 mA field devices. It is used in engineered process-control cabinets for valve, drive and other analog final-element command loops.

Important Notice: Confirm the complete CC-TAOX01 marking, assigned Series-C position, companion output module, terminal-plug identities, conductor polarity, loop supply, load and approved control configuration before removal or commissioning.

额
Apter Power CC-TAOX01 Manuals and Guides
Apter Power CC-TAOX01 Analog Output IOTA Technical Reference PDFCC-TAOX01 Field Wiring and Output-Loop Verification Workbook PDF

The first document organizes model-specific technical data and system identity. The second provides a separate installation, wiring, commissioning and acceptance workflow for CC-TAOX01.

CC-TAOX01 control-valve command terminationTerminates current-command conductors serving compatible valve positioners in a Series-C cabinet.
CC-TAOX01 variable-speed drive referenceRoutes analog speed-reference loops between the installed output electronics and compatible drives.
CC-TAOX01 final-element cabinet wiringProvides an organized sixteen-channel termination base for engineered analog-output field circuits.
CC-TAOX01 output-IOTA renewalSupports controlled IOTA replacement while preserving documented terminal-plug and channel identities.
Read the applicable Honeywell Series-C I/O instructions before work. Verify CC-TAOX01, the assigned output-module position and every connected current loop.
1
Confirm the complete CC-TAOX01 marking and assigned Series-C cabinet position before removal.
2
Place connected final elements in approved manual or safe conditions before disturbing output wiring.
3
Isolate applicable loop power and identify both sixteen-pin terminal plugs and all channel conductors.
4
Use ESD controls and protect the backplane connector, terminal hardware and conformal coating.
5
Match the installed CC-PAOH01 or CC-PAOX01 electronics to the approved system configuration.
6
Verify loop-supply polarity and confirm every connected load remains within the documented limit.
7
Restore power under controlled conditions and review all channel and module diagnostics.
8
Command each active loop at controlled low, midpoint and high values before automatic service.

Technical notes

Technical notes

Label both terminal plugs and every loop conductor before removal. Match the installed CC-PAOH01 or CC-PAOX01 module, verify the 22–28 V DC loop supply and load, then command each channel at controlled values during acceptance.

FAQS

  • Which Series-C position is CC-TAOX01 intended to occupy?
    CC-TAOX01 is the sixteen-point nonredundant analog-output IOTA. Confirm that the installed Series-C project assigns this exact IOTA type to the selected cabinet position.
  • What field signals are terminated by CC-TAOX01?
    CC-TAOX01 terminates sixteen 4 to 20 mA analog-output loops used to command compatible field devices.
  • Which electronics modules pair with CC-TAOX01?
    Honeywell documents CC-PAOH01 and CC-PAOX01 as compatible output modules for the CC-TAOX01 IOTA, together with two sixteen-pin terminal plugs.
  • What loop-supply and load limits apply to CC-TAOX01?
    The documented loop supply is 22 to 28 V DC and the maximum connected load is 800 Ohm.
  • What should be recorded before replacing CC-TAOX01?
    Record both terminal-plug identities, channel assignments, conductor polarity, shields and configured output ranges before disconnecting the IOTA.
  • How should CC-TAOX01 be handled during removal and installation?
    Isolate the applicable loop energy, apply approved ESD controls and protect the backplane connector, terminal hardware and conformal coating from damage.
  • How should CC-TAOX01 be commissioned after installation?
    Restore power under controlled conditions, review module diagnostics and test each output at controlled low, midpoint and high command values.
  • Can CC-TAOX01 be substituted without checking the installed configuration?
    No. Match the complete CC-TAOX01 marking, compatible output module, terminal-plug arrangement, hardware revision and approved control configuration before replacement.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.