Technical specifications for 05704-A-0145
-
Manufacturer:Honeywell
-
Product Category:DCS Systems
-
Spare Part Number:05704-A-0145
-
Estimated shipping dimensions:2.5x17x12.7cm
-
Weight:0.16 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Input signal:4-20 mA
-
Channel count:4
-
System family:System 57 / 5704
-
Loop Protection:Short circuit, open circuit voltage of ±50V
-
Measurement Signal Range:0 to 25mA (linear)
-
Isolation Breakdown Voltage:More than ±50V dc to system 0V
Information
- Four field-current input paths
- System 57 modular control-card architecture
- 5704 rack product-family application
- Multi-channel gas-detection panel support
Installed in a matching 5704 system, the card processes compatible transmitter loop signals for the control arrangement. The rack, field wiring, alarm strategy and associated interface cards define the final monitoring function.
Important Notice: Verify the 05704-A-0145 label, matching 5704 rack position, transmitter loop wiring, configured gas range and alarm configuration before energizing the system.
Apter Power 05704-A-0145 Manuals and Guides
05704-A-0145 Product Technical Reference PDF
Apter Power 05704-A-0145 Installation and Verification Guide
Important Notice: The first PDF is an Apter Power technical reference prepared from directly related Honeywell evidence; the second PDF is an Apter Power installation and verification guide. Confirm the physical nameplate, current Honeywell documentation and installed-system requirements before installation or replacement.
FAQ View All FAQ
-
What host system is required for 05704-A-0145?05704-A-0145 must be used with the matching Honeywell system family and the exact companion hardware stated in the approved project documentation.
-
How should 05704-A-0145 be verified before installation?Match the complete 05704-A-0145 label, installed location, connectors or terminals, wiring and current project configuration before installation.
-
Can 05704-A-0145 replace a similarly named Honeywell item?No direct substitution should be assumed for 05704-A-0145. Confirm the exact identifier, system position and approved replacement procedure before any change.
-
What must be checked when wiring 05704-A-0145?Check the approved terminal assignment, polarity where applicable, shielding or grounding requirements, and all connected companion hardware for 05704-A-0145.
-
How should 05704-A-0145 be commissioned?Commission 05704-A-0145 through the host system's documented functional or loop-check procedure and record the final configuration and test result.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.