MC-PAOX03 51309152-175

Analog Output IOP
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Honeywell MC-PAOX03 51309152-175 is the MC-PAOX03 Analog Output IOP used for generation and supervision of eight independent 4-20 mA analog outputs in a documented PM/APM/HPM Process Manager I/O installation. Confirm the complete identity and installed system configuration before replacement.

Ask our team:

Get a quick price for: MC-PAOX03 51309152-175
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for MC-PAOX03 51309152-175

Technical specifications for MC-PAOX03 51309152-175

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    51309152-175
  • Estimated shipping dimensions:
    3x31.8x28cm
  • Weight:
    0.6 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product type:
    Analog Output I/O Processor
  • IOP model:
    MC-PAOX03
  • Channels:
    8
  • Output range:
    4-20 mA
  • Calibrated accuracy:
    +/-0.35% of full scale at 25 degC
  • Resolution:
    +/-0.05% of full scale
  • Channel architecture:
    Individual DAC and output power per channel
  • Failure action:
    Hold or unpower, configurable
  • Coating:
    Conformally coated
  • Compliance execution:
    CE-compliant part

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell MC-PAOX03 51309152-175 is the MC-PAOX03 Analog Output IOP used for generation and supervision of eight independent 4-20 mA analog outputs in a documented PM/APM/HPM Process Manager I/O installation.
  • Channels: 8
  • Output range: 4-20 mA
  • Calibrated accuracy: +/-0.35% of full scale at 25 degC
  • Resolution: +/-0.05% of full scale

The component remains matched to its installed host, interface hardware and engineering configuration. Commissioning restores that architecture and verifies the intended function under controlled conditions.

Important Notice: Confirm MC-PAOX03 51309152-175, its exact host, installed position, interfaces, configuration, diagnostics and controlled acceptance evidence before release.

MC-PAOX03 51309152-175 Manuals & Downloads

These documents are different: the first consolidates exact product and system data; the second provides model-specific installation checks, commissioning steps and acceptance guidance.

MC-PAOX03 Analog Output IOP
Honeywell MC-PAOX03 51309152-175 is the MC-PAOX03 Analog Output IOP used for generation and supervision of eight independent 4-20 mA analog outputs in a documented PM/APM/HPM Process Manager I/O installation.
Installed-system maintenance
Preserves the documented slot, termination, wiring and configuration during replacement.
Controlled commissioning
Restores power and signals in the approved sequence and reviews diagnostics.
Acceptance verification
Confirms the intended channel, network or safety function before release.
Read the applicable Honeywell installation instructions before work. Verify MC-PAOX03 51309152-175, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete MC-PAOX03 51309152-175 identity on the hardware and maintenance record.
2
Place the affected process in the approved maintenance state.
3
Record the installed position, connectors, terminals, wiring and configuration before removal.
4
Isolate all documented power and field energy and apply ESD controls where required.
5
Inspect the replacement identity, revision, interfaces and mating hardware before installation.
6
Restore every conductor, cable, power path and configuration value to the approved record.
7
Review host, module, channel or network diagnostics after controlled energization.
8
Perform a controlled functional test before release.

Alternative Names

Alternative Names

51309152-175

Technical notes

Technical notes

Install MC-PAOX03 51309152-175 only in its documented PM/APM/HPM Process Manager I/O position. Preserve the exact interfaces, wiring and configuration, then verify diagnostics and generation and supervision of eight independent 4-20 mA analog outputs under controlled conditions.

FAQS

  • How many current outputs does MC-PAOX03 51309152-175 control?
    It controls eight independent 4-20 mA outputs.
  • What calibrated accuracy is specified for MC-PAOX03 51309152-175 at 25 degC?
    The calibrated accuracy is +/-0.35% of full scale.
  • Which resolution applies to MC-PAOX03 51309152-175?
    The specified resolution is +/-0.05% of full scale.
  • Why does each MC-PAOX03 51309152-175 channel have its own DAC and output power?
    A channel fault is kept from disturbing the other seven output paths.
  • What can MC-PAOX03 51309152-175 do when the IOP fails?
    Each output can be configured to hold its last value or unpower.
  • Which protection execution is MC-PAOX03 51309152-175?
    It is the coated, CE-compliant MC execution.
  • What must match when MC-PAOX03 51309152-175 is used redundantly?
    The peer IOP, redundancy FTA, configuration and channel assignments must match.
  • How should MC-PAOX03 51309152-175 be functionally released?
    Command, measure and diagnose every output, then verify any configured failover behavior.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.