Technical specifications for 8C-PAIH51 51454352-175
-
Manufacturer:Honeywell
-
Product Category:DCS Systems
-
Spare Part Number:51454352-175
-
Estimated shipping dimensions:6x15.6x14.3cm
-
Weight:0.3 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Input type:Current; 2-wire or self-powered transmitter
-
Channels:16 single-ended
-
A/D resolution:16 bit
-
Input range:4 to 20 mA through 200 Ohm
-
Scan rate:50 ms
-
Filter:Single-pole RC; -3 dB at 6.5 Hz
-
NMRR at 60 Hz:19 dB
-
Crosstalk, dc to 60 Hz:-60 dB
-
No-damage input:+/-30 V
-
Accuracy at 23.5 +/-2 C:+/-0.075% full scale
-
Accuracy at 0 to 60 C:+/-0.15% full scale
Information
- System role: 16-Channel High-Level Analog Input HART Module
- Integration focus: Compatible Honeywell host and termination hardware
- Replacement focus: Exact assembly, revision and connector match
- Commissioning focus: Wiring, diagnostics and functional response
Use 8C-PAIH51 only with the exact Honeywell host, rack or chassis, companion hardware, cable and project configuration specified for the installed system.
Confirm the complete physical label, system hardware, field connections and project documentation before installation or replacement.
Important Notice: Confirm whether the matching terminal assembly, cable, connector, power accessory, software and current Honeywell documentation are included in the quotation or stock description.
Apter Power 8C-PAIH51 Manuals and Guides
Important Notice: These are two separate Apter Power documents prepared from product-specific Honeywell technical information. Confirm the physical nameplate, installed-system requirements and supplied accessories before configuration or installation.
Technical notes
Choose the IOTA matching the required redundancy.
FAQ View All FAQ
-
How should an engineer verify 200-ohm input path on 8C-PAIH51?Use the 8C-PAIH51 technical limit or configuration stated for 200-ohm input path, then verify it at the installed channel before service.
-
What must be checked for 50 ms scan on 8C-PAIH51?Treat 50 ms scan as a product-specific commissioning point and compare the field condition with the Honeywell hardware configuration.
-
Which system detail controls TAIX51 versus TAIX61 on 8C-PAIH51?The required check concerns TAIX51 versus TAIX61; confirm the connected hardware is the matched component listed for 8C-PAIH51.
-
Why is it important to confirm self-powered transmitter on 8C-PAIH51?For self-powered transmitter, isolate the circuit, record its present configuration and apply the stated Honeywell limit before re-energization.
-
Where should the team validate sixteen-bit conversion on 8C-PAIH51?Validate sixteen-bit conversion directly at the termination or module position and confirm the controller channel reports the same state.
-
What record is required for 6.5 Hz filter on 8C-PAIH51?The engineering record for 8C-PAIH51 should include 6.5 Hz filter, the installed wiring identity and the final functional-test result.
-
How can a configuration mismatch affect temperature accuracy on 8C-PAIH51?Check temperature accuracy against the selected system arrangement; a mismatch can affect channel recognition or field response.
-
What is the final commissioning test for HART variable mapping on 8C-PAIH51?Complete HART variable mapping with a controlled field stimulus and retain the result as the return-to-service baseline.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.