Match the complete marking
Include IS215UCVEH2AF and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered IS215UCVEH2AF with the installed equipment and applicable GE documentation.
Technical specifications for IS215UCVEH2AF
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:IS215UCVEH2AF
-
Weight:0.52 kg
-
Tariff Code:8537101190
-
Controller family:UCVEH2
-
Control platform:Mark VI
-
Mechanical format:Single-slot VME controller
-
Base-family processor:300 MHz Intel Celeron
-
Base-family DRAM:32 MB
-
Base-family primary network:10/100BaseTX Ethernet to UDH
-
Base-family serial ports:COM1 diagnostics; COM2 serial Modbus
Information
- IS215UCVEH2AF serves the mark vi ucve vme controller board role in a configured General Electric system; selection starts with the installed host and full marking.
Fault isolation: Check UDH link and peer communications
Acceptance: Verify controller diagnostics and affected I/O
The GE UCVEH2 description specifies a 300 MHz Intel Celeron, 32 MB of DRAM and a 10/100BaseTX Ethernet interface for the Unit Data Highway. COM1 is reserved for diagnostics and COM2 supports serial Modbus communication. These are base-family facts; the offered AF execution and installed software must be matched independently.
A controller exchange requires its rack slot, project database, network settings, software release and any associated I/O configuration. Save the existing controller state and compare diagnostics, communication and affected control functions after the approved commissioning sequence.
-
General Electric IS215UCVEH2AF technical reference
Apter Power technical reference - PDF, 2 pages. Product identity, engineering context and applicability conditions. -
General Electric IS215UCVEH2AF installation guide
Prepared by Apter Power - PDF, 1 page. Configuration review, safe installation and functional acceptance.
Compatibility scope: Match the AF execution, VME rack position, application release, UDH network assignment and required serial interfaces to the installed controller configuration.
-
Mark VI control core
Serve as a configured controller in a matching turbine-control VME rack. -
Unit Data Highway
Communicate through the documented UCVEH2 Ethernet interface in the approved UDH network. -
Serial integration
Use the configured COM2 Modbus path where the project design calls for it. -
Controller replacement
Restore a matching UCVE execution with the correct software and control database.
Retain IS215UCVEH2AF and all visible revision markings.
Preserve the configured application, network and diagnostic settings.
Match slot, power and connector condition before insertion.
Document UDH and serial-port assignments before exchange.
Use approved turbine-control and electrical isolation procedures.
Verify controller diagnostics and affected I/O after restart.
Alternative Names
Technical notes
Technical basis: GE GEH-6421M, Mark VI Turbine Control System Guide, Volume II, UCVEH2 controller section.
Applicability: GEH-6421M describes the UCVEH2 base controller. Processor, memory and interface entries are family references; confirm AF suffix and installed release applicability before ordering.
FAQ View All FAQ
-
What must be backed up before replacing IS215UCVEH2AF?Save the project database, controller application, software release, network identity and relevant diagnostic records.
-
How can a UDH fault involving IS215UCVEH2AF be separated from a controller fault?Check physical link, switch port, IP assignment and peer communications before changing the board.
-
How should a serial Modbus communication failure involving IS215UCVEH2AF be isolated?Check the configured COM2 settings, cable and termination, addressing and peer-device response before replacing the controller.
-
Does the UCVEH2 base specification prove every AF revision of IS215UCVEH2AF is interchangeable?No. Compare the complete board marking, rack and approved software/hardware compatibility record.
-
What should be checked if IS215UCVEH2AF does not boot in the rack?Check VME power, slot seating, controller status indicators and the approved startup diagnostics.
-
How should an application mismatch on IS215UCVEH2AF be resolved?Restore only the project-approved control database and verify the matched I/O and network configuration.
-
Why is the VME slot relevant to IS215UCVEH2AF?The single-slot controller must mate with the rack connector and assigned control architecture; physical fit alone is insufficient.
-
What constitutes commissioning evidence for IS215UCVEH2AF?Document startup diagnostics, network connections, control-state behavior and affected I/O acceptance checks.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.