GE IC693BEM340 is a Series 90-30 FIP Bus Controller used to connect the PLC to a documented FIP network. Official CPU compatibility records require IC693BEM340 firmware version 3.00 or later with the referenced Series 90-30 CPU releases.
GE IC693BEM340 is a Series 90-30 FIP Bus Controller used to connect the PLC to a documented FIP network. Official CPU compatibility records require IC693BEM340 firmware version 3.00 or later with the referenced Series 90-30 CPU releases.
Interfaces a Series 90-30 PLC with the FIP network
Uses model-specific module firmware
Requires CPU and FIP configuration compatibility
Provides a controlled network path for configured field data
Apply GE IC693BEM340 only in the documented system position after checking its interfaces, companion hardware and configured values.
Important Notice: Confirm the full IC693BEM340 marking, installed revision, compatible hardware and approved commissioning record before release.
The first document presents model-specific technical and system data. The second provides a separate installation, connection, commissioning and acceptance workflow.
FIP network interface
Connects the Series 90-30 controller to a configured FIP fieldbus.
Legacy PLC maintenance
Replaces an identical bus controller after firmware and network checks.
Remote I/O communications
Maintains the documented exchange between the PLC and FIP network devices.
Controlled migration
Preserves FIP addressing and mapped data during a planned module change.
Read the applicable GE instructions before work. Verify GE IC693BEM340 and the installed system configuration before commissioning.
1
Verify the complete IC693BEM340 marking and hardware revision.
2
Record the installed IC693BEM340 firmware before replacement.
3
Use firmware version 3.00 or later where required by the documented CPU release.
4
Back up the Series 90-30 hardware configuration and FIP network parameters.
5
Confirm rack slot, backplane and CPU compatibility before installation.
6
Label all FIP network connections before disconnection.
7
Restore node settings and mapped data without changing the approved topology.
8
Verify bus diagnostics and configured data exchange before release.
Technical notes
Use only the complete GE IC693BEM340 identity and the current manufacturer documentation. Verify the installed revision, companion hardware, wiring and saved configuration before replacement or release.