Technical specifications for IC676PBI008
-
Manufacturer:General Electric
-
Product Category:PLC Systems
-
Spare Part Number:IC676PBI008
-
Weight:0.2 kg
-
Tariff Code:8537101190
-
Input points:8
-
Network protocol:PROFIBUS-DP
-
Network data rate:Up to 12 Mbaud, autobaud
-
Module supply:24 V DC nominal
-
Supply range:18 to 30 V DC
-
Module current at 24 V:35 mA typical; 100 mA maximum
-
Sensor-supply current:4.5 mA typical plus sensors; 700 mA maximum
-
Sensor wiring:2-, 3- and 4-wire
-
Connection style:M12
-
Degree of protection:IP67
-
Operating temperature:-25 to +60 deg C
-
Storage temperature:-25 to +85 deg C
-
Station address:1 to 99
-
Protection:Electronic sensor-supply overload and short-circuit protection
Information
Overview
Downloads
Applications / Compatibility
Product Precautions
- IC676PBI008 acquires eight field sensor states at an IP67 machine location and exchanges their point status directly over PROFIBUS-DP.
Sealed field installation: M12 interfaces and protective caps support IP67 remote-I/O mounting.
Eight-point sensor acquisition: Digital inputs and per-channel status are transmitted directly over PROFIBUS-DP.
Integrated supply diagnostics: Module and sensor power faults are reported locally and to the master.
Eight-point sensor acquisition: Digital inputs and per-channel status are transmitted directly over PROFIBUS-DP.
Integrated supply diagnostics: Module and sensor power faults are reported locally and to the master.
IC676PBI008 is an eight-point VersaMax IP digital input block with a PROFIBUS-DP interface. It uses M12 bus, power and sensor connections for distributed field installation.
The module accepts 24 V DC sensor states, provides protected sensor supply and supports autobaud up to 12 Mbaud. IP67 depends on correct connectors, functional earth and approved caps on every unused port.
Record station address, bus direction, sensor pinout and channel assignments before removal. After replacement, verify supply LEDs, cyclic data, each input state and diagnostic telegrams.
The module accepts 24 V DC sensor states, provides protected sensor supply and supports autobaud up to 12 Mbaud. IP67 depends on correct connectors, functional earth and approved caps on every unused port.
Record station address, bus direction, sensor pinout and channel assignments before removal. After replacement, verify supply LEDs, cyclic data, each input state and diagnostic telegrams.
Controller platform reference: GE VersaMax IP distributed I/O. Follow applicable GE instructions and the approved site drawing.
The product reference covers network, input and enclosure data; the field guide covers M12 mapping, sealing and eight-point tests.
IC676PBI008 Technical Data Reference
GE VersaMax IP 8 Point Input Module datasheet GFK-2292; selected exact-model and documented family data for IC676PBI008.IC676PBI008 Installation & Verification Guide
Model-specific installation, wiring, inspection and commissioning checks for IC676PBI008.
The technical and field documents divide electrical limits from IP67 installation acceptance.
System and supply context: Field-I/O context: The sealed block collects eight machine or process sensor states without a separate indoor slice-I/O rack.
Application scope: Network and enclosure boundary: PROFIBUS addressing, sensor supply, connector coding, unused-port caps and mounting environment must all satisfy the documented IP67 installation.
Application scope: Network and enclosure boundary: PROFIBUS addressing, sensor supply, connector coding, unused-port caps and mounting environment must all satisfy the documented IP67 installation.
Machine sensor collection
Acquire eight proximity, limit or switch signals close to equipment.IP67 remote I/O
Operate in exposed field locations when sealing rules are met.PROFIBUS distributed input
Exchange cyclic input data with the master.Field diagnostics
Use supply, bus and channel status for fault isolation.
Prepare GE IC676PBI008 for its configured installation using these product-specific checks.
Record the station address
Set 1-99 before power-up.
Label BUS IN and BUS OUT
Preserve segment order and termination.
Protect every M12 port
Fit the correct cap to unused connectors.
Maintain functional earth
Retain shield and FE bonding.
Check sensor load
Keep total sensor supply within limits.
Test all eight inputs
Verify channel state and master diagnostics.
Alternative Names
GE IC676PBI008
Eight-Point IP67 PROFIBUS Digital Input Block IC676PBI008
Technical notes
M12 point map: Record each sensor connector, channel designation and supply assignment before disconnecting the block.
Sealing and power: Inspect connector seals, unused-port caps, protective earth and both module and sensor supplies.
Field-node acceptance: Confirm network recognition, eight input transitions and supply diagnostics at the master.
FAQ View All FAQ
-
When does IC676PBI008 accept a newly selected station address?Set the address from 1 to 99 before energization because the value is accepted at power-up.
-
How is IP67 protection maintained on IC676PBI008?Tighten all M12 connections, preserve functional earth and install the correct protective caps on unused ports.
-
What sensor-supply load limit applies to IC676PBI008?The documented maximum is 700 mA for the sensor-supply path, in addition to checking each connected sensor.
-
Why must BUS IN and BUS OUT be preserved for IC676PBI008?Reversing the segment order or termination arrangement can interrupt downstream PROFIBUS communication.
-
Which data-rate behavior does IC676PBI008 support?The interface autobauds up to 12 Mbaud when the network hardware and termination meet the PROFIBUS rules.
-
How does IC676PBI008 respond to a sensor-supply short?Electronic protection limits the affected supply and diagnostic information is reported to the master.
-
Which field-wiring styles can be used with IC676PBI008?The module supports documented 2-, 3- and 4-wire sensor connections through the correct M12 pinout.
-
Which network, supply and eight-input results confirm IC676PBI008?Record master recognition, correct station address, healthy module and sensor power, eight controlled input transitions and clear diagnostics.
Manufacturers
Supporting new and legacy automation
Whether you're maintaining existing equipment or sourcing parts for current systems, we provide fast, dependable supply you can rely on.
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
PRODUCTS IN SEARCH PAGE ()
50+ account managers available now
Related reading
Related cases and sourcing guidance
View all case studies
Manufacturers
You May Also Like
Explore related automation components available through Apter Power.
Manufacturers
Product Browsing History
Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.