Technical specifications for IC200MDL241

  • Manufacturer:
    General Electric
  • Product Category:
    General Automation
  • Spare Part Number:
    IC200MDL241
  • Estimated shipping dimensions:
    11x6.5x6cm
  • Weight:
    0.16 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Platform:
    VersaMax modular I/O
  • I/O type:
    Discrete input
  • Input points:
    16
  • Input voltage:
    24 Vac/Vdc
  • Point arrangement:
    Two groups of 8
  • Mounting:
    VersaMax carrier
  • Signal class:
    AC/DC discrete

Information

Overview Manuals Common Applications Product Precautions
GE IC200MDL241 is a VersaMax sixteen-point 24 Vac/Vdc discrete input module. It acquires field on/off states and transfers them into the configured VersaMax I/O station.
  • Acquires sixteen field-state inputs for the VersaMax I/O station
  • Groups the input points into two documented banks
  • Transfers discrete state data to the VersaMax network interface or controller
  • Provides a modular input point for machine and process status collection

IC200MDL241 installs with VersaMax carrier, VersaMax network interface or CPU, 24 Vac/Vdc field circuits, Approved field terminal assembly in an engineered GE VersaMax modular I/O configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this versamax 16-point 24 vac/vdc discrete input module.

Important Notice: Confirm the complete IC200MDL241 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power IC200MDL241 Manuals and Guides
Apter Power IC200MDL241 VersaMax Input Module ReferenceApter Power IC200MDL241 Field-Wiring & Commissioning Guide
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Machine interlock status collectionAcquires sixteen field-state inputs for the VersaMax I/O station
Valve and actuator position feedbackGroups the input points into two documented banks
Distributed process alarm inputsTransfers discrete state data to the VersaMax network interface or controller
VersaMax cabinet retrofitProvides a modular input point for machine and process status collection
Read the applicable GE installation instructions before work. Verify IC200MDL241 and the installed GE VersaMax modular I/O configuration.
1Verify the full IC200MDL241 marking and carrier position before removing the module.
2Isolate 24 Vac/Vdc field circuits and the VersaMax station supply before terminal work.
3Record the two input groups, terminal labels and channel assignments.
4Confirm the carrier keying and module orientation before insertion.
5Use ESD controls and keep the terminal assembly free of conductive debris.
6Check field polarity and common wiring against the approved VersaMax drawing.
7Restore the input map and debounce or diagnostic settings defined by the project.
8Apply controlled field states and record every channel response before service release.

Technical notes

Mount IC200MDL241 on the specified VersaMax carrier, preserve the two eight-point group wiring and validate each input state against the project channel map.

FAQ View All FAQ

  • What voltage does IC200MDL241 accept?
    The VersaMax data identifies IC200MDL241 as a 24 Vac/Vdc discrete input module.
  • How many input points are provided by IC200MDL241?
    IC200MDL241 provides sixteen discrete input points arranged as two groups of eight.
  • Which carrier is required for IC200MDL241?
    Install IC200MDL241 on the compatible VersaMax carrier and verify the carrier keying and station position before wiring.
  • What wiring record is needed before replacing IC200MDL241?
    Record each terminal, common, group assignment and controller channel so the two eight-point banks can be restored without crossing circuits.
  • How should 24 Vac and 24 Vdc sources be handled during IC200MDL241 service?
    Isolate the field circuits and station supply, then confirm the source type and polarity against the approved wiring drawing before reconnection.
  • How is IC200MDL241 checked during commissioning?
    Apply a controlled on/off condition to every assigned input and compare the observed state with the configured VersaMax channel map.
  • What diagnostic evidence should be retained for IC200MDL241?
    Retain the final carrier position, group wiring record, channel map and per-point functional test results.
  • Can an adjacent VersaMax input module be substituted for IC200MDL241?
    Do not substitute by appearance; the voltage class, point count, group arrangement, keying and approved project configuration must match.