Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

IC200ALG620

Analog Input RTD Module
In Stock
Ships by Saturday, July 18
Fast Shipping Available

Product Describe:

Analog Input RTD Module
Platinum 25, 100, and 1000 ohm
Copper 10, 50, and 100 ohm
Nickel 100 and 120 ohm
Nickel / Iron 604 ohms

Ask our team:

Get a quick price for: IC200ALG620
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for IC200ALG620

Technical specifications for IC200ALG620

  • Manufacturer:
    General Electric
  • Product Category:
    Gas turbine control
  • Spare Part Number:
    IC200ALG620
  • Estimated shipping dimensions:
    11x6x6.7cm
  • Weight:
    0.18 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Points:
    4 POINT
  • Resolution:
    16 BIT
  • Bus Voltage:
    5 Volts DC
  • Resistance input range:
    0-500 Ohms; 0-3000 Ohms
  • Isolation (Input to Frame):
    1500 Volts AC
  • Isolation (Input to Logic):
    250 Volts AC
  • Normal mode rejection:
    60dB, at 50/60 Hz, 100% span
  • Common mode rejection:
    120 dB at 50/60Hz, 100 ohm imbalance
  • Common mode voltage:
    3V maximum
  • Normal mode voltage:
    5V maximum
  • Digital Resolution:
    15 bits plus sign
  • Operating temperature range:
    0 to 60 Degrees C ambient

Information

Information

Overview Manuals Common Applications IC200ALG620 Guidelines
The IC200ALG620 is an intelligent, 4-channel, 16-bit high-precision analog input RTD module designed for the GE VersaMax series. Requiring no external power supply, it autonomously generates and matches the correct excitation current for various 3-wire and 4-wire RTD sensors, including Platinum, Nickel, Copper, and Nickel/Iron. Users can individually configure each channel, select resistance ranges between 0-500 and 0-3000 ohms, and choose to output data as raw resistance or in tenths of degrees Celsius or Fahrenheit.
    • Selectable RTD input as resistance or temperature (Celsius or Fahrenheit)
    • Reports high/low, under-range/over-range, open wire and input short alarms
    • Two data acquisition rates based on 50 Hz and 60 Hz line frequencies
The module features robust monitoring that real-time reports high/low, under/over-range, open wire, and input short circuit alarms to the PLC. It offers two data acquisition rates optimized for 50 Hz and 60 Hz line frequencies to suppress ambient electrical interference.

Additionally, the module performs an automatic A/D calibration at powerup and repeats this process periodically during operation, effectively eliminating measurement drift caused by ambient temperature changes to ensure long-term data stability.

The mechanical enclosure of this module features a tool-free click-in structure that locks onto standard VersaMax carriers, completing all data communication and logic interaction via the internal backplane bus. Its hardware architecture includes high-isolation electrical protection circuitry, preventing external surges or ground loop noise from transmitting to the core PLC central processing unit.

The module retains channel configurations even during power loss. In the event of a field hardware replacement, a new module automatically receives parameter downloads from the controller the moment it is plugged into the carrier and powered up, achieving industrial-grade module replacement and plug-and-play functionality.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
 General Electric IC200ALG620 Analog Input RTD Module Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Oil and Gas Industry
Used for monitoring bearing temperatures at pumping stations along long-distance pipelines and real-time monitoring of multi-point temperatures within crude oil storage tanks.

Thermal Power and Heating Industry
Used for the precise measurement of boiler feedwater temperatures, steam pipeline wall temperatures, and medium temperatures within urban district heating exchange stations.

Pharmaceutical Machinery Industry
Used for internal temperature verification of autoclaves and precise control of shelf temperatures in pharmaceutical freeze dryers (lyophilizers).

Metallurgy and Metal Processing Industry
Cyclicly collects multi-point temperatures in industrial heat treatment furnaces (such as annealing and quenching furnaces) to ensure uniform heating of metal materials.

Plastics and Rubber Molding Industry
Used for precise closed-loop temperature control of multi-stage heating zones in injection molding barrels and heating platens in rubber vulcanizing machines.

Lithium-ion Battery and New Energy Manufacturing Industry
Performs high-density multi-point temperature compliance monitoring in battery cell high-temperature aging rooms and vacuum baking ovens.
 If an IC200ALG620 module is configured to measure 0-500 or 0-3000 Ohms resistance, and the actual resistance is at the low end of the range, then the analog-to-digital conversion produces zero (a short circuit). When this occurs, the module reports the configured Channel Default value from the Input Parameters tab of the module configuration. If configured for 0 500, this happens below 2.9 Ohms. If configured for 0-3000, this happens below 22.1 Ohms.

The IC200ALG620 has four RTD channels. When all four channels are configured to inactive mode, head-ends including CPUs or NIUs will report a “loss of IO module” fault that points to the IC200ALG620 itself. To avoid this fault, you should configure at least one channel as active. When IC200ALG630 or IC200ALG620 modules are present in GNIU or PNIU rack and a 'Clear all' command is issued from Machine Edition software, Machine Edition may get disconnected, displaying timeout error "error 8097 - host disconnect has occurred".

When this error is logged, the Configuration is still cleared. To avoid this error “Request Timeout” value in “Additional Configuration” in “Target Properties” should be increased to 30s or more.

Revisions

Revisions

Revision Part #

Also known as

IC200ALG620AA
IC200ALG620-AA, Series AA, Rev AA
IC200ALG620CB
IC200ALG620-CB, Series CB, Rev CB
IC200ALG620DC
IC200ALG620-DC, Series DC, Rev DC
IC200ALG620EC
IC200ALG620-EC, Series EC, Rev EC
IC200ALG620ED
IC200ALG620-ED, Series ED, Rev ED
IC200ALG620JF
IC200ALG620-JF, Series JF, Rev JF
IC200ALG620KF
IC200ALG620-KF, Series KF, Rev KF
IC200ALG620LF
IC200ALG620-LF, Series LF, Rev LF

Alternative Names

Alternative Names

1C200ALG620 1C2OOALG62O IC200ALG62O IC20OALG620 IC2O0ALG620 IC2OOALG62O

Technical notes

Technical notes

The General Electric IC200ALG620 is a 4-channel Analog Input RTD Module from the VersaMax series. It captures resistance signals from field RTD sensors and converts them into digital data for the PLC. Each channel integrates electrical isolation and utilizes hardware-level filtering within the enclosure to suppress electromagnetic cross-talk and high-frequency noise from long-distance transmission, ensuring continuous and stable process temperature acquisition.

FAQS

  • What is IC200ALG620?
    It is a 4-channel, 16-bit high-precision analog input module within the GE VersaMax PLC series, specifically designed for temperature measurement by connecting to RTD (Resistance Temperature Detector) sensors.
  • How do you use the IC200ALG620?
    Plug it into a corresponding VersaMax carrier, connect the RTD sensor cables, and configure the channel types via Proficy Machine Edition software. The PLC can then directly read the converted digital temperature values.
  • What types of RTD sensors does the IC200ALG620 support?
    It supports Platinum (25/100/1000 ohms), Copper (10/50/100 ohms), Nickel (100/120 ohms), and Nickel/Iron (604 ohms) sensors.
  • How many input channels does the IC200ALG620 have?
    The module provides 4 fully independent input channels.
  • What wiring configurations does the IC200ALG620 support?
    It supports 3-wire and 4-wire RTD wiring methods to compensate for lead resistance errors in long-distance cables.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.