Speak to a sourcing specialist
sales13@apterpower.com

IC660BBS102

115 VAC/125 VDC 8-circuit Isolated I/O Block with Diagnostics
In Stock
Ships by Sunday, November 29
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

GE IC660BBS102 is a 115 VAC/125 VDC 8-circuit Isolated I/O Block with Diagnostics for the GE Genius I/O. It provides the documented field interface or control function in the configured system.
Get a quick price for IC660BBS102
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for IC660BBS102

  • Manufacturer:
    General Electric
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IC660BBS102
  • Estimated shipping dimensions:
    8.5x10x22.5cm
  • Weight:
    1.45 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Discrete circuits:
    8
  • Circuit grouping:
    Four isolated pairs
  • Failed Switch diagnostic:
    Included
  • Replaces:
    IC660BBS100
  • Operating power:
    93 to 132 VAC or 105 to 132 VDC
  • Block isolation:
    1500 V
  • Continuous group isolation:
    250 VAC/VDC
  • Transient group isolation:
    2000 V for 10 seconds
  • Heat dissipation:
    16.8 W inputs; 45.6 W outputs
  • Selectable input filter:
    10 to 100 ms
  • Maximum output current:
    2 A

Information

Overview Manuals Common Applications Product Precautions
IC660BBS102 provides the documented 115 vac/125 vdc 8-circuit isolated i/o block with diagnostics role for a matched GE Genius I/O installation.
  • Provides the documented 115 vac/125 vdc 8-circuit isolated i/o block with diagnostics function
  • Uses exact catalog identity IC660BBS102 for replacement control
  • Integrates with the matched GE Genius I/O hardware
  • Supports controlled connection checks and functional verification

The component is used with the exact terminal assembly, carrier, power grouping and bus configuration identified for IC660BBS102. Commissioning preserves the installed point map and verifies controlled field response.

Important Notice: Confirm IC660BBS102, GE Genius I/O host, hardware revision, terminal or connector type, power and signal ranges, wiring, grounding, bus configuration, companion accessories and controlled commissioning results before service release.

GE IC660BBS102 Manuals & Downloads

These are two different documents: the technical reference consolidates verified product and system data; the installation guide provides field checks, commissioning steps and acceptance records.

GE Genius I/O station maintenance
Restores the documented 115 vac/125 vdc 8-circuit isolated i/o block with diagnostics function in an engineered station.
Distributed I/O refurbishment
Uses exact IC660BBS102 identity when rebuilding the recorded field interface.
Control-panel modernization
Preserves the approved terminal, power and communications arrangement during migration work.
Controlled recommissioning
Verifies point mapping, diagnostics and field response before process release.
Read the applicable General Electric installation instructions before work. Verify IC660BBS102, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the full IC660BBS102 catalog marking and installed GE Genius I/O position before work.
2
Isolate the station supply and connected field energy using the approved procedure.
3
Record every terminal, common, shield, connector and configured point before removal.
4
Use ESD controls and protect backplane, terminal and connector contacts from contamination.
5
Verify each documented value for IC660BBS102 against the installed host and field circuit.
6
Restore the approved terminal assembly, power grouping and configuration record.
7
Energize in the prescribed sequence and review module, bus and point diagnostics.
8
Complete a controlled signal or load test before returning the station to service.

Technical notes

Install IC660BBS102 only in the documented GE Genius I/O position. Preserve the as-found terminal mapping and configuration, then verify diagnostics and the affected field function under controlled conditions.

FAQ View All FAQ

  • How is IC660BBS102 identified?
    Match the complete catalog number and the 115 VAC/125 VDC 8-circuit Isolated I/O Block with Diagnostics designation.
  • Which system accepts IC660BBS102?
    Use the documented GE Genius I/O carrier, terminal and bus arrangement.
  • What records are retained before removing IC660BBS102?
    Record terminals, commons, shields, connectors, point mapping and diagnostics.
  • How is IC660BBS102 isolated safely?
    Isolate station and field supplies, prove the safe state and apply ESD controls.
  • Which official values govern IC660BBS102?
    Discrete circuits: 8; Circuit grouping: Four isolated pairs; Failed Switch diagnostic: Included; Replaces: IC660BBS100.
  • How is IC660BBS102 configuration restored?
    Restore the approved hardware execution, power grouping and point map.
  • Which diagnostics follow IC660BBS102 energization?
    Review module, bus and channel status in the prescribed startup sequence.
  • What releases IC660BBS102 to service?
    A controlled signal or load test with the expected field response and no active diagnostic.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.