PR6426-010-140 operates with PR6426-compatible converter, Rigid 80 x 40 mm mounting surface, Ten-metre armored route, Installed adapter and LEMO connection.
Engineered applications include Remote large-gap position loops, Long-run expansion monitoring, Heavy-machine axial displacement, Armored actuator-position measurement.
Important Notice: Confirm the separate adapter, mounting-plate alignment, ten-metre armored route and PR6426 range; verify the complete large-gap response before enabling protection.
The first document provides model-specific technical and measurement-system reference data. The second is a separate field workbook for mounting, wiring, commissioning and acceptance records.
Measures large target movement at remote machine points.
Supports expansion channels with a protected ten-metre route.
Observes axial displacement on heavy rotating equipment.
Provides non-contact position sensing in mechanically exposed installations.
Verify the complete PR6426-010-140 order code, 80 x 40 mm mounting plate mounting interface and assigned PR6426 32 mm eddy-current system measuring point before work.
Place the monitored machine and its protection channel in the approved maintenance state before disturbing PR6426-010-140.
Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
Route the 10 m sensor lead without sharp bends, crushing, tensile load or contact with hot and moving surfaces.
Keep the LEMO or open-end connection clean, dry and fully identified before reconnecting the measurement loop.
Confirm the paired signal converter or monitor input, cable length and target material match the documented measuring chain.
Set the static gap within the documented linear region while preserving shaft and probe mechanical clearance.
Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.