Technical specifications for PR6426-010-140
-
Manufacturer:Emerson
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:PR6426-010-140
-
Estimated shipping dimensions:25x20x4.5cm
-
Weight:0.85 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Sensor family:PR6426
-
Sleeve thread:None
-
Armor:Yes
-
Mounting plate:80 x 40 mm
-
Adapter plug:Not included
-
Total cable length:10 m
-
Cable end:LEMO
-
Static nominal range:+/-4.0 mm
-
Sensitivity:2 V/mm
-
Nominal distance center:Approximately 5.5 mm
-
Basic air gap:1.2 to 1.8 mm
-
Operating temperature:-35 to +150 degC
-
Vibration endurance:5 g at 60 Hz
Information
- Protects the large-range probe lead with armor
- Provides a ten-metre system cable
- Uses an 80 x 40 mm mounting plate
- Requires separate documented adapter hardware
PR6426-010-140 operates with PR6426-compatible converter, Rigid 80 x 40 mm mounting surface, Ten-metre armored route, Installed adapter and LEMO connection.
Engineered applications include Remote large-gap position loops, Long-run expansion monitoring, Heavy-machine axial displacement, Armored actuator-position measurement.
Important Notice: Confirm the separate adapter, mounting-plate alignment, ten-metre armored route and PR6426 range; verify the complete large-gap response before enabling protection.
Apter Power PR6426-010-140 Manuals and Guides
Apter Power PR6426-010-140 Measurement-System Technical Reference PDFApter Power PR6426-010-140 Installation, Loop Check and Acceptance Workbook PDFThe first document provides model-specific technical and measurement-system reference data. The second is a separate field workbook for mounting, wiring, commissioning and acceptance records.
Remote large-gap position loops
Measures large target movement at remote machine points.
Long-run expansion monitoring
Supports expansion channels with a protected ten-metre route.
Heavy-machine axial displacement
Observes axial displacement on heavy rotating equipment.
Armored actuator-position measurement
Provides non-contact position sensing in mechanically exposed installations.
Verify the complete PR6426-010-140 order code, 80 x 40 mm mounting plate mounting interface and assigned PR6426 32 mm eddy-current system measuring point before work.
Place the monitored machine and its protection channel in the approved maintenance state before disturbing PR6426-010-140.
Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
Route the 10 m sensor lead without sharp bends, crushing, tensile load or contact with hot and moving surfaces.
Keep the LEMO or open-end connection clean, dry and fully identified before reconnecting the measurement loop.
Confirm the paired signal converter or monitor input, cable length and target material match the documented measuring chain.
Set the static gap within the documented linear region while preserving shaft and probe mechanical clearance.
Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.
Technical notes
FAQ View All FAQ
-
What measurement or system function does PR6426-010-140 perform?PR6426-010-140 is a pr6426 large-range eddy-current displacement sensor. It senses shaft-to-probe displacement for a matched Emerson signal converter and machinery-monitoring channel.
-
Which installed hardware must be paired with PR6426-010-140?Use PR6426-010-140 with the documented Emerson PR6426 32 mm eddy-current measurement system components: PR6426-compatible converter, Rigid 80 x 40 mm mounting surface, Ten-metre armored route.
-
How should the Sensor family value for PR6426-010-140 be verified?Confirm the complete nameplate and order code before work; the documented sensor family is PR6426.
-
What connection detail is critical when installing PR6426-010-140?Preserve every conductor, connector and shield identity, then follow the model-specific connection arrangement described in the controlling Emerson document.
-
How is PR6426-010-140 mechanically installed without changing measurement behavior?Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
-
What commissioning test should be completed for PR6426-010-140?Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.
-
What configuration record should be retained when replacing PR6426-010-140?Retain the as-found position, sleeve thread, cable or channel identity, gap or scaling value, diagnostics and final functional-test result.
-
Can PR6426-010-140 replace a similar Emerson model without engineering review?No direct substitution should be assumed; verify the full order code, measuring function, interface, cable or channel arrangement and the approved Emerson PR6426 32 mm eddy-current measurement system configuration.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.