Product Describe:

Emerson EZ1081-07-00-010 + EZ1901-090 combines an 8 mm M10 × 1 armoured proximity probe with an armoured extension cable. The 70 mm case, 1 m integral lead and 9 m extension form a 10 m electrical chain for a matched EZ1000 converter.
  • Manufacturer part number
    EZ1081-07-00-010 + EZ1901-090
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    17cm x 17cm x 2cm
  • Country of Origin
    USA
Get a quick price for EZ1081-07-00-010 + EZ1901-090
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete Emerson EZ1081-07-00-010 + EZ1901-090 reference, label photographs and required quantity. Include photographs of both cable labels and the converter calibration reference.

  • 1

    Confirm the offer

    Review the offered revision, condition, included items and documents against the confirmed installation.

  • 2

    Arrange dispatch

    Confirm quantity, dispatch date, lead-time start and delivery details in the quotation.

  • Match the complete marking

    Match the complete Emerson EZ1081-07-00-010 + EZ1901-090 marking and the installed configuration. Compare both component labels and the 10 m calibrated chain.

  • Check the offered item before ordering

    Please request clear photographs of Emerson EZ1081-07-00-010 + EZ1901-090, including its complete label and interfaces. Ask your maintenance team to compare the offered unit with the installed equipment and the applicable Emerson AMS EZ 1000 sensor installation guide before approving the order.

Technical specifications for EZ1081-07-00-010 + EZ1901-090

  • Manufacturer:
    Emerson
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    EZ1081-07-00-010 + EZ1901-090
  • Weight:
    0.2 kg
  • Tariff Code:
    8537101190
  • Sensing tip:
    8 mm
  • Mounting thread:
    M10 × 1
  • Case length:
    70 mm
  • Ordered unthreaded section:
    00; fixed 5 mm tip neck still present
  • Integral lead:
    1 m; armoured
  • Extension cable:
    9 m; armoured
  • Total electrical length:
    10 m
  • Nominal sensitivity:
    8 V/mm ISO; 7.87 V/mm API
  • Nominal gap:
    1.5 mm
  • Probe temperature:
    -35 to +180 °C, including 1 m lead
  • Extension / connector temperature:
    -35 to +150 °C
  • Armoured-cable bend radius:
    Minimum 35 mm

Information

Overview Downloads Applications / Compatibility Product Precautions
  • A 70 mm threaded case provides additional mounting reach while the 9 m extension carries the signal to the converter. The longer body changes the mounting geometry; it does not increase the electrical measurement range of the 10 m transducer chain.
Probe configuration: 8 mm tip, M10 × 1, 70 mm case
Cable chain: 1 m probe lead + 9 m armoured extension
Converter matching: 10 m complete electrical length
The EZ1081 probe uses a GF30 PEEK sensing tip, stainless-steel body and protected cable construction. Its selected 70 mm case has the ordered unthreaded section set to 00. A fixed 5 mm neck remains behind the tip and must not be treated as available mounting thread.

The EZ1901 extension contributes 9 m to the 10 m chain. A compatible EZ1000 converter must be calibrated for the complete assembly and intended target. The nominal scale factor is 8 V/mm for ISO calibration or 7.87 V/mm for API calibration; a 1.5 mm nominal gap is a reference point within the matched system.

The 10 m electrical chain uses the general recommended dynamic range of no more than 1250 µm peak-to-peak. The separate 2000 µm recommendation for a standard 5 m API-calibrated chain must not be assigned to this configuration. Probe and integral cable operation is -35 to +180 °C, while extension cables and connectors are limited to -35 to +150 °C.
Controller platform reference: AMS EZ 1000 transducer system. Match the complete 10 m chain and target calibration.
Technical material for Emerson EZ1081-07-00-010 + EZ1901-090 covers probe construction, 70 mm case selection, 9 m armoured extension and calibrated-chain limits. The separate installation guide covers 70 mm mounting, 10 m chain identification, armoured cable routing and target-response verification.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
System and supply context: Use the stated probe and extension with an EZ1000 converter calibrated for 10 m and the intended target. The converter, mounting hardware and protection monitor are separate items.

Application scope: A 70 mm threaded case provides additional mounting reach while the 9 m extension carries the signal to the converter. The longer body changes the mounting geometry; it does not increase the electrical measurement range of the 10 m transducer chain.
Prepare Emerson EZ1081-07-00-010 + EZ1901-090 for its configured installation using these checks.
Preserve electrical length

Do not cut or splice the 10 m chain or exchange extension lengths without matching calibration.

Keep the tip clear

Maintain the specified target area, surrounding-metal clearance and fixed neck clearance.

Control torque

Limit EZ108x locknut torque to 15 N·m and prevent cable twisting.

Separate temperature limits

Keep extension cables and connectors within +150 °C even if the probe location permits +180 °C.

Protect the joint

Use the specified hand-tightened connection and heat-shrink insulation; apply additional hazardous-area requirements where relevant.

Check the operating point

Verify gap, target response and channel indication before restoring machinery monitoring.

Alternative Names

Emerson EZ1081-07-00-010 + EZ1901-090 EZ1081-07-00-010 / EZ1901-090

Technical notes

Signal relationship: Total electrical length is 1 m + 9 m = 10 m. Mechanical case length does not change this calculation and does not establish the displacement range.

Installation boundary: Keep the armoured cable bend radius at least 35 mm and stored loop diameter at least 100 mm. Avoid continuous oil immersion and direct oil-stream exposure; leave allowance for installation and thermal movement.

Technical basis: Emerson AMS EZ 1000 Sensor Installation Guide, MHM-97883 Rev. 1.09, January 2025. The order-code tables map the 70 mm EZ1081 probe and 9 m EZ1901 extension to a 10 m chain. Performance remains conditional on target and matched converter calibration.

FAQ View All FAQ

  • Does the 70 mm case in EZ1081-07-00-010 + EZ1901-090 increase displacement range?
    No. Case length controls mounting reach. The 8 mm sensing tip and matched 10 m electrical chain determine the measurement response.
  • What makes the EZ1901-090 section of EZ1081-07-00-010 + EZ1901-090 an armoured extension?
    EZ1901 identifies the protected extension-cable construction and 090 selects 9 m. Together with the 1 m integral lead it produces a 10 m chain.
  • How much target material should be present behind the measurement area of EZ1081-07-00-010 + EZ1901-090?
    A target-material thickness of 12 mm is recommended for the specified sensor geometry. Thin targets can change the response and require an appropriate application assessment.
  • Why should EZ1081-07-00-010 + EZ1901-090 face the target as nearly square as possible?
    Probe tilt changes the measurement geometry. The installation guidance recommends an angle below 4° for the stated low scale-factor deviation condition.
  • What happens if the 10 m lead path of EZ1081-07-00-010 + EZ1901-090 is shortened on site?
    The calibrated electrical length changes. Do not cut or splice the probe or extension cable; select and calibrate the required complete combination.
  • Which sensitivity convention applies to EZ1081-07-00-010 + EZ1901-090?
    The system uses 8 V/mm for ISO calibration or 7.87 V/mm for API calibration. The actual converter calibration and target must be identified before selecting a scale factor.
  • How should the longer case of EZ1081-07-00-010 + EZ1901-090 be secured during tightening?
    Support and hold the probe case, keep the fixed tip neck clear and limit locknut torque to 15 N·m. Do not transmit tightening torque into the cable.
  • Can EZ1081-07-00-010 + EZ1901-090 be installed over a very small target face?
    Target area influences the response. The measurement-area diameter should be at least 14 mm, with more than 20 mm recommended for the stated low-error geometry; evaluate the actual shaft or target before installation.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.