CON041

PR642x eddy-current sensor signal converter
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

Emerson CON041 is a PR642x eddy-current sensor signal converter. It powers and conditions a supported PR642x probe and delivers a proportional voltage signal from a DIN-rail control-cabinet installation.

Ask our team:

Get a quick price for: CON041
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for CON041

Technical specifications for CON041

  • Manufacturer:
    Emerson
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    CON041
  • Estimated shipping dimensions:
    16x15x2cm
  • Weight:
    0.15 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Alternative models:
    SNG-CON041; SNG-CON041-SF
  • Mounting:
    DIN rail
  • Compatible sensors:
    PR6422; PR6423; PR6424; PR6426
  • Standard PR6422 range:
    1 mm; linearity <=1.5%
  • Standard PR6423 range:
    2 mm; linearity <=1.0%
  • Standard PR6424 range:
    4 mm; linearity <=1.5%
  • Standard PR6426 range:
    8 mm; linearity <=1.5%
  • Voltage output:
    -4 to -20 V DC
  • Installation environment:
    Control cabinet

Information

Information

Overview Manuals Common Applications Product Precautions
Emerson CON041 is pr642x eddy-current sensor signal converter. It powers and conditions a supported PR642x probe and delivers a proportional voltage signal from a DIN-rail control-cabinet installation.
  • Mounts on a control-cabinet DIN rail
  • Supports four documented PR642x probe families
  • Provides family-specific standard measuring spans
  • Outputs a proportional negative DC voltage

CON041 operates with PR6422, PR6423, PR6424 or PR6426 probe, DIN-rail cabinet position, Negative DC supply and signal wiring, Compatible Emerson or third-party voltage input.

Engineered applications include Compact radial-vibration channels, Axial displacement loops, Differential expansion monitoring, Large-gap shaft-position measurement.

Important Notice: Match the converter setup to the exact PR6422/3/4/6 probe, isolate cabinet power, preserve terminal identity and confirm gap voltage plus full-range response after DIN-rail installation.

Apter Power CON041 Manuals and Guides

Apter Power CON041 Measurement-System Technical Reference PDFApter Power CON041 Installation, Loop Check and Acceptance Workbook PDF

The first document provides model-specific technical and measurement-system reference data. The second is a separate field workbook for mounting, wiring, commissioning and acceptance records.

Compact radial-vibration channels

Conditions PR6422 signals for compact shaft measurements.

Axial displacement loops

Supports PR6423 or PR6424 thrust and shaft-position loops.

Differential expansion monitoring

Provides an installation-ready cabinet converter for expansion channels.

Large-gap shaft-position measurement

Pairs with PR6426 for the documented eight-millimetre standard span.

Read the applicable Emerson machinery-monitoring instructions before work. Verify CON041 and the installed PR642x DIN-rail eddy-current transducer system configuration.
1

Confirm the complete CON041/SNG-CON041/SNG-CON041-SF identity and paired probe family before replacement.

2

Place the monitored machine and protection channel in the approved maintenance state.

3

Isolate cabinet power and record every supply, signal and shield terminal.

4

Release the DIN-rail latch without bending terminals or stressing adjacent converters.

5

Use ESD controls and keep the sensor connector plus terminal area clean and dry.

6

Restore the probe-family range and verify it matches PR6422, PR6423, PR6424 or PR6426.

7

Set the probe static gap within the correct family linear region and record the quiescent output.

8

Prove polarity, full-range response and alarm action before returning the channel to service.

Alternative Names

Alternative Names

SNG-CON041 SNG-CON041-SF

Technical notes

Technical notes

Match the converter setup to the exact PR6422/3/4/6 probe, isolate cabinet power, preserve terminal identity and confirm gap voltage plus full-range response after DIN-rail installation.

FAQS

  • What measurement or system function does CON041 perform?
    CON041 is a pr642x eddy-current sensor signal converter. It powers and conditions a supported PR642x probe and delivers a proportional voltage signal from a DIN-rail control-cabinet installation.
  • Which installed hardware must be paired with CON041?
    Use CON041 with the documented PR642x DIN-rail eddy-current transducer system components: PR6422, PR6423, PR6424 or PR6426 probe, DIN-rail cabinet position, Negative DC supply and signal wiring.
  • How should the Converter model value for CON041 be verified?
    Confirm the complete nameplate and order code before work; the documented converter model is CON041.
  • What connection detail is critical when installing CON041?
    Preserve every conductor, connector and shield identity, then follow the model-specific connection arrangement described in the controlling Emerson document.
  • How is CON041 mechanically installed without changing measurement behavior?
    Isolate cabinet power and record every supply, signal and shield terminal.
  • What commissioning test should be completed for CON041?
    Prove polarity, full-range response and alarm action before returning the channel to service.
  • What configuration record should be retained when replacing CON041?
    Retain the as-found position, alternative models, cable or channel identity, gap or scaling value, diagnostics and final functional-test result.
  • Can CON041 replace a similar Emerson model without engineering review?
    No direct substitution should be assumed; verify the full order code, measuring function, interface, cable or channel arrangement and the approved PR642x DIN-rail eddy-current transducer system configuration.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.