Technical specifications for CON041
-
Manufacturer:Emerson
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:CON041
-
Estimated shipping dimensions:16x15x2cm
-
Weight:0.15 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Alternative models:SNG-CON041; SNG-CON041-SF
-
Mounting:DIN rail
-
Compatible sensors:PR6422; PR6423; PR6424; PR6426
-
Standard PR6422 range:1 mm; linearity <=1.5%
-
Standard PR6423 range:2 mm; linearity <=1.0%
-
Standard PR6424 range:4 mm; linearity <=1.5%
-
Standard PR6426 range:8 mm; linearity <=1.5%
-
Voltage output:-4 to -20 V DC
-
Installation environment:Control cabinet
Information
- Mounts on a control-cabinet DIN rail
- Supports four documented PR642x probe families
- Provides family-specific standard measuring spans
- Outputs a proportional negative DC voltage
CON041 operates with PR6422, PR6423, PR6424 or PR6426 probe, DIN-rail cabinet position, Negative DC supply and signal wiring, Compatible Emerson or third-party voltage input.
Engineered applications include Compact radial-vibration channels, Axial displacement loops, Differential expansion monitoring, Large-gap shaft-position measurement.
Important Notice: Match the converter setup to the exact PR6422/3/4/6 probe, isolate cabinet power, preserve terminal identity and confirm gap voltage plus full-range response after DIN-rail installation.
Apter Power CON041 Manuals and Guides
Apter Power CON041 Measurement-System Technical Reference PDFApter Power CON041 Installation, Loop Check and Acceptance Workbook PDFThe first document provides model-specific technical and measurement-system reference data. The second is a separate field workbook for mounting, wiring, commissioning and acceptance records.
Compact radial-vibration channels
Conditions PR6422 signals for compact shaft measurements.
Axial displacement loops
Supports PR6423 or PR6424 thrust and shaft-position loops.
Differential expansion monitoring
Provides an installation-ready cabinet converter for expansion channels.
Large-gap shaft-position measurement
Pairs with PR6426 for the documented eight-millimetre standard span.
Confirm the complete CON041/SNG-CON041/SNG-CON041-SF identity and paired probe family before replacement.
Place the monitored machine and protection channel in the approved maintenance state.
Isolate cabinet power and record every supply, signal and shield terminal.
Release the DIN-rail latch without bending terminals or stressing adjacent converters.
Use ESD controls and keep the sensor connector plus terminal area clean and dry.
Restore the probe-family range and verify it matches PR6422, PR6423, PR6424 or PR6426.
Set the probe static gap within the correct family linear region and record the quiescent output.
Prove polarity, full-range response and alarm action before returning the channel to service.
Alternative Names
Technical notes
FAQ View All FAQ
-
What measurement or system function does CON041 perform?CON041 is a pr642x eddy-current sensor signal converter. It powers and conditions a supported PR642x probe and delivers a proportional voltage signal from a DIN-rail control-cabinet installation.
-
Which installed hardware must be paired with CON041?Use CON041 with the documented PR642x DIN-rail eddy-current transducer system components: PR6422, PR6423, PR6424 or PR6426 probe, DIN-rail cabinet position, Negative DC supply and signal wiring.
-
How should the Converter model value for CON041 be verified?Confirm the complete nameplate and order code before work; the documented converter model is CON041.
-
What connection detail is critical when installing CON041?Preserve every conductor, connector and shield identity, then follow the model-specific connection arrangement described in the controlling Emerson document.
-
How is CON041 mechanically installed without changing measurement behavior?Isolate cabinet power and record every supply, signal and shield terminal.
-
What commissioning test should be completed for CON041?Prove polarity, full-range response and alarm action before returning the channel to service.
-
What configuration record should be retained when replacing CON041?Retain the as-found position, alternative models, cable or channel identity, gap or scaling value, diagnostics and final functional-test result.
-
Can CON041 replace a similar Emerson model without engineering review?No direct substitution should be assumed; verify the full order code, measuring function, interface, cable or channel arrangement and the approved PR642x DIN-rail eddy-current transducer system configuration.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.