    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 7379A06G02 3A99160G02

  • Manufacturer:
    Emerson
  • Product Category:
    DCS Systems
  • Spare Part Number:
    7379A06G02 3A99160G02
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product type:
    QCI digital contact-input card
  • Channel count:
    16
  • Input arrangement:
    Common return
  • Open-circuit voltage:
    42 to 56 V; 48 V nominal
  • Closed-contact current:
    6 to 22 mA; 14 mA nominal
  • Always rejected pulse:
    Less than 2.6 ms
  • Always passed pulse:
    Greater than 6.0 ms
  • Leakage resistance:
    50 kilohms minimum
  • Closed-circuit resistance:
    60 ohms maximum by wiring equation
  • Minimum open-close cycle:
    Greater than 15 ms

Information

Overview Manuals Common Applications Product Precautions
In a WDPF Q-Line contact path, WESTINGHOUSE 7379A06G02 3A99160G02 converts field-contact states into two eight-bit DIOB bytes. Cable resistance, leakage, filter timing and address jumpers are key acceptance points.
  • Sixteen filtered contact inputs
  • 48 V nominal contact wetting
  • Optical isolation per input
  • Selectable data-bit polarity

Prove the QCI path with controlled contact changes on both eight-bit groups while checking wetting voltage, leakage, filter response, polarity and DIOB addressing.

Important Notice: De-energize or isolate connected contact circuits before handling WESTINGHOUSE 7379A06G02 3A99160G02.

WESTINGHOUSE 7379A06G02 3A99160G02 Manuals & Downloads
WESTINGHOUSE 7379A06G02 3A99160G02 Official Technical Reference Excerpt (PDF)WESTINGHOUSE 7379A06G02 3A99160G02 Installation & Commissioning Guide (PDF)

The official excerpt identifies the combined QCI assembly and filtering behavior; the installation guide covers two-byte addressing, wetting circuits, leakage and contact-state proving.

Machine-status input
Collects sixteen dry-contact indications.
Protection-contact monitoring
Filters short disturbances before DIOB transfer.
Legacy Q-Line replacement
Restores the exact combined QCI card identity.
Digital input troubleshooting
Separates contact, cable, wetting supply, filter and DIOB checks.
Isolate the 48 V wetting supply and map both eight-bit contact groups before disturbing the combined QCI assembly.
1
De-energize or isolate connected contact circuits before handling WESTINGHOUSE 7379A06G02 3A99160G02.
2
Preserve both identifiers in the combined model record and verify the G02 group.
3
Record all channel assignments, polarity inversion settings and address jumpers.
4
Keep open-contact leakage resistance at or above 50 kilohms.
5
Apply the 60-ohm closed-circuit wiring equation to every field path.
6
Do not expect pulses shorter than 2.6 ms to pass the digital filter.
7
Verify the 48 V nominal wetting supply and each channel LED.
8
Release the card only after all used contacts, polarity settings and DIOB bytes pass.

Technical notes

WESTINGHOUSE 7379A06G02 3A99160G02 is a sixteen-channel Q-Line QCI digital contact-input card with an isolated 48 V wetting supply.

FAQ View All FAQ

  • How many inputs belong to WESTINGHOUSE 7379A06G02 3A99160G02?
    The QCI card provides sixteen digitally filtered contact inputs.
  • Which wetting voltage is used by WESTINGHOUSE 7379A06G02 3A99160G02?
    Its isolated supply provides 48 V nominal contact wetting, with a 42 to 56 V open-circuit range.
  • What current is documented for a closed contact on WESTINGHOUSE 7379A06G02 3A99160G02?
    The closed-contact current is 6 to 22 mA, nominally 14 mA.
  • Which pulses are rejected by WESTINGHOUSE 7379A06G02 3A99160G02?
    Input changes shorter than 2.6 ms are always rejected.
  • Which pulses pass the WESTINGHOUSE 7379A06G02 3A99160G02 filter?
    Input changes longer than 6.0 ms are always passed.
  • What leakage resistance is required for WESTINGHOUSE 7379A06G02 3A99160G02?
    Open-contact shunt resistance must be at least 50 kilohms to maintain the specified wetting voltage.
  • How is polarity handled by WESTINGHOUSE 7379A06G02 3A99160G02?
    Group 02 permits the polarity of individual data bits to be inverted by configuration.
  • What completes WESTINGHOUSE 7379A06G02 3A99160G02 acceptance?
    Verify wetting supply, address jumpers, inversion settings, filter response, channel LEDs and both DIOB data bytes.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.