Product Describe:

<div style="font-family:'Poppins','Century Gothic',Arial,sans-serif;font-size:16px;font-weight:400;color:#333;line-height:1.5;text-align:left;">WESTINGHOUSE 5X00109G01 provides the field-interface layer for eight 4-20 mA HART channels. Each channel can be arranged for a field-powered or locally powered transmitter and pairs with 5X00106G01 or 5X00106G02 electronics.</div>
Get a quick price for 5X00109G01
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 5X00109G01

  • Manufacturer:
    Emerson
  • Product Category:
    DCS Systems
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product class:
    HART high-performance analog-input personality module
  • Channel count:
    8
  • Signal range:
    4-20 mA
  • Input protection:
    One fuse per channel
  • Channel configuration:
    Field powered or locally powered by two jumpers per channel
  • Paired electronics:
    5X00106G01 or 5X00106G02
  • Subsystem resolution:
    16 bit
  • Cable:
    Single twisted pair with overall shield

Information

Overview Manuals Common Applications Product Precautions
WESTINGHOUSE 5X00109G01 routes eight HART current loops while preserving separate channel fusing and jumper selection. Unlike the G02 revision, the documented G01 description does not add active current limiting in two-wire mode.
  • Eight fused HART channels
  • 4-20 mA high-performance input
  • Per-channel power-selection jumpers
  • 5X00106 electronics pairing

The installed signal path is HART transmitter → 5X00109G01 personality module → 5X00106 input electronics → Ovation analog and HART data. Record the as-left channel assignment and verify the affected path before release.

Important Notice: Remove auxiliary loop power and verify every channel before handling WESTINGHOUSE 5X00109G01.

WESTINGHOUSE 5X00109G01 Manuals & Downloads
WESTINGHOUSE 5X00109G01 Official Technical Reference Excerpt (PDF)WESTINGHOUSE 5X00109G01 Installation & Commissioning Guide (PDF)

The Technical Reference presents the applicable model data and interface details; the Installation & Commissioning Guide organizes field preparation, controlled replacement and acceptance checks for WESTINGHOUSE 5X00109G01.

Smart-transmitter inputs
Connects eight HART-capable current loops to Ovation.
Mixed power arrangements
Allows each channel to follow its installed local- or field-powered design.
Loop protection
Places an individual fuse at every channel interface.
HART troubleshooting
Supports separate current, fuse, jumper and digital-communication checks.
Apply these controls to WESTINGHOUSE 5X00109G01 before isolation, removal, reconnection, energization and release.
1
Remove auxiliary loop power and verify every channel before handling WESTINGHOUSE 5X00109G01.
2
Confirm the complete G01 identity and its installed 5X00106 electronics module.
3
Record both jumpers on every channel before removing the personality module.
4
Keep paired jumpers together in either the field-powered or locally powered position.
5
Do not treat G01 as the G02 current-limited revision.
6
Maintain shielded twisted-pair routing and the approved shield termination.
7
Correct the loop fault before replacing any channel fuse.
8
Commission analog accuracy and HART communication independently on every used channel.

Technical notes

WESTINGHOUSE 5X00109G01 is an eight-channel Ovation HART high-performance analog-input personality module with fused inputs and per-channel power-selection jumpers.

FAQ View All FAQ

  • What is the input-channel capacity of WESTINGHOUSE 5X00109G01?
    It provides eight fused HART analog-input channels.
  • Which current range belongs to WESTINGHOUSE 5X00109G01?
    The documented subsystem range is 4-20 mA.
  • How is channel power selected on WESTINGHOUSE 5X00109G01?
    Two user-accessible jumpers per channel select field-powered or locally powered operation.
  • Which electronics modules pair with WESTINGHOUSE 5X00109G01?
    The documented pairings are 5X00106G01 and 5X00106G02.
  • What distinguishes WESTINGHOUSE 5X00109G01 from G02?
    G02 adds active current limiting in two-wire mode; that feature is not assigned to G01.
  • Why must both jumpers move together on WESTINGHOUSE 5X00109G01?
    The pair defines the channel power path and must remain in the same documented position.
  • How should a blown channel fuse on WESTINGHOUSE 5X00109G01 be handled?
    Locate and clear the field-loop fault, fit the specified replacement, then prove current and HART communication.
  • Which tests close WESTINGHOUSE 5X00109G01 commissioning?
    Verify jumper positions, loop polarity, current accuracy, fuse status, cable shield and HART access on every used channel.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.