Product image is representative; revision or series may vary. Contact us to request a specific version.
Product Describe:
Emerson KJ4002X1-BF2 12P3866X012 identifies a DeltaV bottom extender cable assembly. Current manufacturer carrier documentation specifies KJ4002X1-BF2 as the 1.2 m, 44-pin extender-cable execution.
Between compatible horizontal carriers, KJ4002X1-BF2 continues the backplane connection through a documented 1.2 m cable. Acceptance depends on connector keying, cable length, bend protection and the controlled carrier-power path.
KJ4002X1-BF2 12P3866X012
KJ4002X1-BF2
1.2 m
44-pin extender cable
Retain the exact host position, connections and configuration record. Complete controlled diagnostics and a functional test before service release.
Important Notice: Confirm KJ4002X1-BF2 12P3866X012, every companion marking and the recorded acceptance result before replacement.
The technical reference consolidates product identity and interface data; the installation guide provides separate readiness, configuration, verification and handover checks.
Separated-carrier connection
Extends the DeltaV backplane between compatible horizontal-carrier sections.
Cabinet routing
Supports a documented 1.2 m route without changing the carrier sequence.
Maintenance replacement
Keeps the complete cable identity and both keyed ends under one record.
Power-boundary validation
Requires verification of the carrier load before re-energization.
Read the applicable product and site instructions before work. Verify KJ4002X1-BF2 12P3866X012, the installed host and every connected interface before isolation or replacement.
1
Confirm the complete Emerson KJ4002X1-BF2 12P3866X012 marking against the receiving record before work.
2
Place the connected process, rack, machinery and control functions in the approved maintenance state.
3
Record the installed position, wiring, terminal hardware, settings and companion components before removal.
4
Isolate every affected electrical and process-energy source and verify the safe state.
5
Protect keyed connectors, terminals and electronics from contamination, strain and electrostatic damage.
6
Restore only the recorded wiring, grounding, shielding, settings and matched companion hardware.
7
Energize in the controlled sequence and review every available module, rack and system diagnostic.
8
Function-test horizontal-carrier backplane extension and retain the signed acceptance result before service release.
Technical notes
Evidence boundary: Manufacturer documentation identifies the complete base model and cable execution; the 12P item marking is retained exactly. Use Emerson KJ4002X1-BF2 12P3866X012 only after the physical marking, installed position, terminal hardware and companion equipment have been reconciled.
What is the documented purpose of Emerson KJ4002X1-BF2 12P3866X012?
Emerson KJ4002X1-BF2 12P3866X012 identifies a DeltaV bottom extender cable assembly. Current manufacturer carrier documentation specifies KJ4002X1-BF2 as the 1.2 m, 44-pin extender-cable execution.
Which product family contains Emerson KJ4002X1-BF2 12P3866X012?
The documented base model belongs to the DeltaV M-series product family.
Which function is documented for Emerson KJ4002X1-BF2 12P3866X012?
For the documented base model, cable length is 1.2 m.
What channel or interface detail applies to Emerson KJ4002X1-BF2 12P3866X012?
For the documented base model, connector is 44-pin extender cable.
Which power boundary applies to Emerson KJ4002X1-BF2 12P3866X012?
For the documented base model, assembly type is Bottom extender cable assembly.
Which environmental limit applies to Emerson KJ4002X1-BF2 12P3866X012?
For the documented base model, electrical rating is 12.6 V DC, 15 A.
What diagnostic or maintenance point applies to Emerson KJ4002X1-BF2 12P3866X012?
For the documented base model, operating temperature is -40 to 70°C.
What should be verified after installing Emerson KJ4002X1-BF2 12P3866X012?
Verify the complete marking, installed interfaces, retained settings, diagnostics and controlled operation of horizontal-carrier backplane extension before release.