Product Describe:

Bently Nevada 9200-01-01-10-00 is a moving-coil velocity transducer. The moving coil generates a voltage from absolute casing motion without an external excitation supply.
  • Manufacturer part number
    9200-01-01-10-00
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    4.2cm x 4.2cm x 11.5cm
  • Country of Origin
    USA
Get a quick price for 9200-01-01-10-00
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 9200-01-01-10-00 reference, label photographs and required quantity. Include the installed interface and hardware revision.

  • 1

    Confirm the offer

    Review the offered 9200-01-01-10-00 execution, New, original product condition and itemized accessories against the retained application.

  • 2

    Arrange dispatch

    Confirm quantity, dispatch date, lead-time start and delivery details in the quotation.

  • Match the complete marking

    Compare the full Bently Nevada 9200-01-01-10-00 marking, hardware execution and mating interfaces with the installed position before approving a replacement.

  • Check the offered item before ordering

    Request clear photographs of the offered 9200-01-01-10-00 marking and connections. Ask the maintenance team to compare them with the applicable Bently Nevada instructions and the installed circuit or system design.

Technical specifications for 9200-01-01-10-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    9200-01-01-10-00
  • Weight:
    0.46 kg
  • Tariff Code:
    8537101190
  • Sensitivity:
    20 mV/mm/s (500 mV/in/s), ±5% at calibration conditions
  • Calibration load:
    10 kΩ
  • Frequency response:
    4.5–1000 Hz, +0/−3 dB typical
  • Coil resistance:
    1.25 kΩ ±5%
  • Locked-coil inductance:
    125 mH typical
  • Maximum displacement:
    2.54 mm peak-to-peak
  • Calibration orientation:
    0° ±2.5°
  • Mounting thread:
    M10 x 1
  • Operating temperature:
    −29 to +121 °C

Information

Overview Downloads Applications / Compatibility Product Precautions
  • This execution has a top connector arrangement and a circular M10 x 1 mounting stud; it is intended for a calibrated near-vertical measurement axis.
Self-generating measurement: moving-coil velocity signal without sensor excitation
Measurement location: top connector access for casing or bearing-housing installations
Signal interpretation: absolute housing motion along the calibrated axis
A properly oriented installation and the receiving instrument load jointly determine the velocity indication. The calibration reference uses a 10 kΩ load at approximately 22 °C and a 100 Hz excitation. A receiver with a different loading characteristic needs an engineering assessment before its scale factor is accepted.

Casing measurements depend on transmission of machine vibration to the mounting point. The sensing path therefore includes the housing structure and mechanical mounting, rather than only the transducer and monitor. A rigid, appropriate bearing-housing position helps preserve the intended amplitude and frequency response.

A compatible portable instrument can receive the passive signal without adding a sensor excitation supply. Connect to an appropriate velocity-monitor input with the required loading and scale. Bracket movement changes the mechanical transfer path and may introduce resonance. Correct the mounting and repeat the measurement before changing monitor calibration.
Controller platform reference: Seismoprobe velocity system. Use the applicable installation instructions and approved system design.
Original Bently Nevada technical pages applicable to 9200-01-01-10-00 and its stated system context. Installation topics include: establish the casing reference; keep the mounting base mechanically rigid; trace the passive signal pair.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
Prepare Bently Nevada 9200-01-01-10-00 for its configured installation using these checks.
Establish the casing reference

Record the bearing-housing position and the direction of expected motion. Compare the mounting axis with the vertical calibration before removing the existing sensor.

Keep the mounting base mechanically rigid

Inspect the M10 x 1 attachment and mating surface. Correct damage or looseness so that the case follows the machine surface rather than an unsupported bracket.

Trace the passive signal pair

Identify pins A and B through the interconnect cable. Keep the transducer signal separate from powered transmitter wiring; this moving-coil device does not require an excitation supply.

Check the receiver loading

Record the monitor input impedance and velocity scale. Resolve deviations from the calibration load before accepting a change in indicated vibration.

Compare controlled motion and phase

Use a suitable calibrated vibration reference with the machine safely isolated. Check indicated amplitude and polarity over relevant operating frequencies, then retain the baseline result.

Control the return to service

Keep the affected process in its approved maintenance state until field indications and the intended control or monitoring response have both been checked.

Alternative Names

Bently Nevada 9200-01-01-10-00

Technical notes

Configuration scope: Technical values apply to 9200-01-01-10-00 with the stated operating conditions. Check supplied revision and the configured installation.

Engineering acceptance: The intended moving-coil velocity transducer function must be accepted with its actual mating interfaces and configured system. Identify pins A and B through the interconnect cable. Keep the transducer signal separate from powered transmitter wiring; this moving-coil device does not require an excitation supply.

FAQ View All FAQ

  • Why can 9200-01-01-10-00 indicate a different velocity after changing the receiving instrument?
    The receiver loads the coil. Compare the new input impedance with the 10 kΩ calibration load before attributing a changed reading to the machine.
  • How should a low-speed measurement with 9200-01-01-10-00 be assessed?
    Check whether the important fault frequencies lie above the selected low-frequency response limit. Motion below that band can be attenuated even when the rotor is moving significantly.
  • What makes mounting orientation important for 9200-01-01-10-00?
    Its moving assembly is calibrated near the vertical axis. A mechanically convenient tilt can change the transducer response; preserve the specified orientation instead of compensating with an arbitrary software gain.
  • Can a casing measurement from 9200-01-01-10-00 substitute directly for shaft-relative displacement?
    No. A casing transducer responds to absolute housing motion, while a proximity system observes shaft motion relative to its mounting. Their physical reference and diagnostic meaning differ.
  • How can 9200-01-01-10-00 help distinguish wiring polarity from a true phase change?
    Pin A becomes positive relative to pin B as case velocity moves toward the connector. Check that convention through the cable and receiver before interpreting phase relationships.
  • Why should a loose bracket be corrected before scaling 9200-01-01-10-00?
    Bracket movement changes the mechanical transfer path and may introduce resonance. Correct the mounting and repeat the measurement before changing monitor calibration.
  • What limits the use of long cables with 9200-01-01-10-00?
    Cable length can alter high-frequency response. The 305 m maximum connection to applicable 3300 or 3500 monitors is not an assurance of identical response for every cable and receiving impedance.
  • How should an unexpectedly small output from 9200-01-01-10-00 be investigated?
    Check motion direction, mounting rigidity, connector continuity and receiver loading. A low output can reflect a poor vibration path or installation error, not necessarily low machine vibration.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.