Technical specifications for 3500/93
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:3500/93
-
Estimated shipping dimensions:2.5x25.8x24cm
-
Weight:0.85 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Product role:3500 System Display
-
Rack data interface:High-speed 3500 serial data
-
Display output:VGA
-
Touch-controller interface:RS-232
-
Status indicators:OK and COMM LEDs
-
Power consumption:4.6 W maximum
-
Operating temperature:-30 to +65 degC
-
Storage temperature:-40 to +85 degC
-
Humidity:95%, noncondensing
Information
- Uses high-speed rack data
- Supports a VGA operator display
- Provides RS-232 touch-controller communication
- Reports operating state through OK and COMM indicators
3500/93 operates with 3500 monitoring rack, compatible VGA display, RS-232 touch controller, approved display and configuration cabling.
Engineered applications include Local rack status display, Operator machinery overview, Maintenance diagnostics station, 3500 display-system renewal.
Important Notice: Verify 3500/93, the display-system assembly role, rack communications cable, VGA output, touch-controller link and configured display database before replacement; test OK and COMM indications after restart.
Apter Power Bently Nevada 3500/93 Manuals and Guides
Apter Power Bently Nevada 3500/93 Product Technical Reference PDFApter Power Bently Nevada 3500/93 Installation and Verification Workbook PDFThe first document presents model-specific technical and system data. The second provides a separate installation, connection, commissioning and acceptance workflow.
Local rack status display
Shows machinery and rack information near the protected asset.
Operator machinery overview
Presents operator status and alarm information.
Maintenance diagnostics station
Supports maintenance review of monitored variables.
3500 display-system renewal
Restores a documented display path while retaining communications wiring.
Verify the complete 3500/93 marking and its assigned 3500 VGA display system position before work.
Place the connected local rack status display process in the approved maintenance state.
Isolate applicable power and high-speed rack data to vga display and rs-232 touch controller field energy before disconnecting conductors.
Record connector, conductor, address, firmware and software identities before removal.
Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.
Confirm the installed 3500 monitoring rack and compatible VGA display against the approved project.
Restore power in a controlled sequence and review device, network and host diagnostics.
Prove the intended operator machinery overview function and retain the final test result.
Technical notes
FAQ View All FAQ
-
Which installed system position is intended for 3500/93?Install 3500/93 only in the documented 3500 VGA display system position and compare the complete catalog marking with the approved hardware list.
-
What field signals or controlled function does 3500/93 handle?Its documented role is high-speed rack data to vga display and rs-232 touch controller; preserve the assigned channel, network or controller function during service.
-
Which companion hardware must be matched to 3500/93?Match 3500/93 with 3500 monitoring rack and compatible VGA display, including the documented rack, cable and project identity.
-
Which electrical rating must be checked before wiring 3500/93?Verify product role: 3500 System Display. Do not transfer limits from another catalog number.
-
What configuration should be recorded before replacing 3500/93?Record the as-found position, conductors, addressing, firmware and software revision, then restore only the approved 3500 VGA display system configuration.
-
Which isolation and handling controls apply to 3500/93?Isolate all documented supply and field energy, use ESD controls and protect keyed connectors before handling 3500/93.
-
How should an engineer commission 3500/93?Power up in a controlled sequence, review device and host diagnostics, then prove the intended local rack status display function.
-
Can 3500/93 replace a visually similar module without an engineering review?No automatic substitution is assumed; compare the complete catalog number, interfaces, ratings and approved system revision.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.