Product Describe:

Bently Nevada 3500/61E 285694-02 identifies the 3500/61E six-channel temperature monitor spare configured for non-isolated RTD inputs. It is used in 3500 ENCORE rack-upgrade applications that retain compatible 3300-series temperature I/O wiring.
Get a quick price for 3500/61E 285694-02
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 3500/61E 285694-02

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    3500/61E 285694-02
  • Estimated shipping dimensions:
    5.8x28.5x23.2cm
  • Weight:
    1.22 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Monitor Family:
    3500/61E
  • Spare Part Number:
    285694-02
  • Channel Count:
    Six
  • Input Execution:
    Non-isolated RTD
  • Rack Role:
    3500 ENCORE temperature monitor
  • Legacy I/O Use:
    Designed for compatible 3300/30 and 3300/35 I/O modules
  • Front-panel Indicators:
    OK, TX/RX, Bypass and Alarm
  • Configuration:
    3500/01 Software version 4.0 or later
  • System 1 Requirement:
    Version 6.75 or later
  • ENCORE 2 Requirement:
    Version 4.6 or later
  • Alarm Logic:
    User-programmable Alert and Danger functions
  • Replacement Boundary:
    Match installed I/O type and retained 3300 wiring

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 3500/61E 285694-02 adds a documented temperature monitor execution to the installed machinery-monitoring path.
  • Provides six non-isolated RTD temperature channels.
  • Supports a 3500 ENCORE upgrade while retaining compatible 3300 temperature I/O wiring.
  • Carries exact spare identity 285694-02 in the product ordering table.
  • Uses current monitor diagnostics and programmable alarm processing.

The ENCORE monitor replaces the processing module while the existing compatible I/O arrangement remains part of the measurement path. Channel type, legacy wiring, software revision and alarm configuration must all be checked during replacement.

Important Notice: Keep the complete 3500/61E 285694-02 identity together and verify every mating component before installation.

Bently Nevada 3500/61E 285694-02 Manuals & Downloads
Official 3500/61E Temperature Monitor Specification Excerpt (PDF)Bently Nevada 3500/61E 285694-02 Installation & Commissioning Guide (PDF)

The Technical Reference organizes the exact ordering identity, applicable characteristics and system boundary for this temperature monitor. The Installation & Commissioning Guide covers identification, pre-installation checks, connections, functional verification and the acceptance record.

Bearing temperature
Process six RTD channels for machine-bearing temperature monitoring.
Rack modernization
Upgrade a compatible 3300 temperature-monitor position within a 3500 ENCORE system.
Process temperature
Trend machine-related RTD measurements and alarm against configured limits.
Legacy wiring retention
Reuse approved 3300-series I/O hardware without rewiring the entire field circuit.
Use the complete Bently Nevada 3500/61E 285694-02 identity and the applicable controlled procedure before work.
1
Verify the complete 3500/61E 285694-02 identity and non-isolated RTD execution.
2
Confirm the installed legacy I/O module is supported by the 3500/61E arrangement.
3
Record every channel assignment and RTD type before removing the existing monitor.
4
Check the required 3500/01, System 1 and ENCORE 2 software revisions.
5
Preserve approved rack and field isolation procedures during replacement.
6
Restore Alert, Danger, bypass and channel configuration exactly.
7
Check each channel for correct temperature and wiring-fault behavior.
8
Verify communications, alarms and the machine acceptance record before release.

Technical notes

Keep the complete 3500/61E 285694-02 identity together and verify every mating component before installation.

FAQ View All FAQ

  • What is Bently Nevada 3500/61E 285694-02?
    It is the 3500/61E six-channel temperature monitor spare for non-isolated RTD inputs.
  • How many channels does Bently Nevada 3500/61E 285694-02 provide?
    It provides six temperature channels.
  • Which input type belongs to Bently Nevada 3500/61E 285694-02?
    Part 285694-02 is the non-isolated RTD execution.
  • Where is Bently Nevada 3500/61E 285694-02 used?
    It is designed for compatible 3500 ENCORE rack-upgrade applications.
  • Which legacy I/O does Bently Nevada 3500/61E 285694-02 support?
    The source identifies compatible 3300/30 and 3300/35 temperature I/O arrangements.
  • Which software must be checked for Bently Nevada 3500/61E 285694-02?
    Verify 3500/01 version 4.0 or later, System 1 version 6.75 or later and ENCORE 2 version 4.6 or later.
  • Can the RTD configuration be omitted when replacing Bently Nevada 3500/61E 285694-02?
    No. Channel type, range, alarms and retained I/O wiring must be restored.
  • What confirms commissioning of Bently Nevada 3500/61E 285694-02?
    Confirm all six channel readings, wiring-fault response, communications and alarm operation.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.