Bently Nevada 3500/20 125744-02
Bently Nevada 3500/20 125744-02
Bently Nevada 3500/20 125744-02
Bently Nevada 3500/20 125744-02
Bently Nevada 3500/20 125744-02
Bently Nevada 3500/20 125744-02
Product image is representative; revision or series may vary. Contact us to request a specific version.

3500/20 125744-02

Rack Interface Module
In Stock
Ships by Sunday, September 13
Fast Shipping Available

Product Describe:

Bently Nevada 3500/20 125744-02 is a Rack Interface Module. It manages rack communications, configuration access and system-level status exchange.

Ask our team:

Get a quick price for: 3500/20 125744-02
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 3500/20 125744-02

Technical specifications for 3500/20 125744-02

  • Manufacturer:
    Bently Nevada
  • Product Category:
    PLC Systems
  • Spare Part Number:
    125744-02
  • Estimated shipping dimensions:
    2.5x25x24cm
  • Weight:
    0.84 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Power consumption:
    4.75 W typical
  • Front-panel interface:
    RS232
  • Front-panel protocol:
    ASCII
  • Front-panel baud rate:
    9600 or 19200 baud
  • Network protocol:
    Bently Nevada proprietary
  • Network maximum data rate:
    38.4 kbaud
  • RS232 maximum cable length:
    30 m
  • RS422 maximum cable length:
    1200 m
  • External modem cable length:
    3 m typical
  • Rack addresses:
    63 selectable
  • System-contact current:
    Less than 1 mA dc
  • OK relay rating:
    5 A at 24 Vdc or 120 Vac
  • Operating temperature:
    -30 to +65 degC
  • Storage temperature:
    -40 to +85 degC
  • Relative humidity:
    95% non-condensing
  • Front rack space:
    1 full-height slot

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 3500/20 125744-02 is a Rack Interface Module for the 3500 machinery-protection system. It manages rack communications, configuration access and system-level status exchange.
  • Provides the primary configuration and communication interface for a 3500 rack
  • Collects rack status and monitoring information for compatible host software
  • Supports front-panel local serial access and rear host-network connections
  • Coordinates rack address, keylock and system-contact functions

3500/20 125744-02 installs with 3500 rack, 125768-01 or approved RIM I/O module, Rack Configuration Software, RS232 or RS422 host network in an engineered 3500 Machinery Protection System configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this rack interface module.

Important Notice: Confirm the complete 3500/20 125744-02 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power 3500/20 125744-02 Manuals and Guides
Apter Power 3500/20 125744-02 Product Technical Reference PDFBently Nevada 3500/20 125744-02 Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Local rack configurationProvides the primary configuration and communication interface for a 3500 rack
Plant host data collectionCollects rack status and monitoring information for compatible host software
Multi-rack communication networksSupports front-panel local serial access and rear host-network connections
Machinery-protection system status integrationCoordinates rack address, keylock and system-contact functions
Read the applicable Bently Nevada installation instructions before work. Verify 3500/20 125744-02 and the installed 3500 Machinery Protection System configuration.
1Identify the complete 125744-02 marking and assigned 3500 rack before replacement.
2Place the protected machine and rack communication clients in an approved maintenance state.
3Isolate rack power and external contact circuits before removing the RIM.
4Preserve the rack address, serial interface selection, baud rate and host topology.
5Use ESD controls and protect the front serial connector and backplane contacts.
6Match the rear RIM I/O module to the installed RS232, RS422 or modem arrangement.
7Restore the approved rack configuration and verify CONFIG OK before remote access.
8Test host data retrieval, rack reset and OK relay behavior before release.

Technical notes

Technical notes

Record the rack address, keylock state, rear I/O execution and host serial settings before removal; after installation confirm CONFIG OK, rack communication and system-contact operation.

FAQS

  • Which rear I/O module should be paired with 3500/20 125744-02?
    Use the rear I/O execution documented for the installed serial interface and rack topology; verify the complete I/O part number before insertion.
  • How is the rack address handled when replacing 3500/20 125744-02?
    Record the installed rack address before removal, restore the same unique address and verify host communication before reconnecting remote clients.
  • Which serial path is appropriate for local setup of 3500/20 125744-02?
    The front-panel RS232 ASCII interface is the local configuration path; use the documented baud selection and approved cable.
  • What must be recorded before removing 3500/20 125744-02?
    Record keylock state, rack address, host link type, communication rate, system-contact wiring and the current diagnostic condition.
  • How should host communication be tested after installing 3500/20 125744-02?
    Confirm CONFIG OK, establish communication from the assigned workstation and verify configuration access plus rack-data retrieval.
  • Can 3500/20 125744-02 be inserted in any 3500 rack slot?
    Use the Rack Interface Module position defined by the 3500 rack architecture and pair it with the corresponding rear I/O module.
  • What does an engineer verify if 3500/20 125744-02 shows a communication fault?
    Check rack address, interface selection, cable type and length, baud rate, rear I/O seating and host configuration before changing hardware.
  • What evidence should be retained after commissioning 3500/20 125744-02?
    Retain the complete part identity, restored rack configuration, host-communication test, system-contact results and final diagnostics.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.