Bently Nevada 3500/60 163179-01
Bently Nevada 3500/60 163179-01
Bently Nevada 3500/60 163179-01
Bently Nevada 3500/60 163179-01
Bently Nevada 3500/60 163179-01
Bently Nevada 3500/60 163179-01
Product image is representative; revision or series may vary. Contact us to request a specific version.

3500/60 163179-01

Six-Channel Temperature Monitor
In Stock
Ships by Sunday, September 13
Fast Shipping Available

Product Describe:

Bently Nevada 3500/60 163179-01 is a Six-Channel Temperature Monitor. It processes RTD and thermocouple inputs for continuous machine-temperature indication and alarm protection.

Ask our team:

Get a quick price for: 3500/60 163179-01
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 3500/60 163179-01

Technical specifications for 3500/60 163179-01

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    163179-01
  • Estimated shipping dimensions:
    2.6x25.3x24cm
  • Weight:
    0.8 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Input channels:
    1 to 6
  • Supported input types:
    RTD; thermocouple
  • Input impedance:
    10 MOhm per lead
  • Power consumption:
    7 W nominal
  • Recorder output:
    4-20 mA
  • Recorder load:
    0-600 Ohm
  • Recorder resolution:
    0.3662 uA per bit
  • Recorder update rate:
    100 ms or less
  • Type E range:
    -100 to +1000 degC
  • Type J range:
    -18 to +760 degC
  • Type K range:
    -18 to +1370 degC
  • Type T range:
    -160 to +400 degC
  • Platinum RTD alpha 0.00385:
    -200 to +850 degC
  • Platinum RTD alpha 0.00392:
    -200 to +700 degC
  • Nickel RTD:
    120 Ohm; 3-wire or 4-wire
  • Operating temperature:
    -30 to +65 degC
  • Storage temperature:
    -40 to +85 degC
  • Relative humidity:
    95% non-condensing
  • Front rack space:
    1 full-height slot
  • Functional safety:
    SIL 2

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 3500/60 163179-01 is a six-channel Temperature Monitor for the 3500 rack. It processes RTD and thermocouple inputs for continuous machine-temperature indication and alarm protection.
  • Conditions six RTD or thermocouple temperature channels
  • Supports mixed sensor types when each channel is configured for its installed element
  • Generates temperature alarms and recorder signals for machinery protection
  • Can participate in adjacent-monitor temperature voting arrangements

3500/60 163179-01 installs with 3500 rack, Approved RTD/TC I/O module, RTD or thermocouple field sensors, 3500 Rack Configuration Software in an engineered 3500 Machinery Protection System configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this six-channel temperature monitor.

Important Notice: Confirm the complete 3500/60 163179-01 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power 3500/60 163179-01 Manuals and Guides
Apter Power 3500/60 163179-01 Product Technical Reference PDFBently Nevada 3500/60 163179-01 Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Bearing-metal temperature protectionConditions six RTD or thermocouple temperature channels
Generator winding-temperature monitoringSupports mixed sensor types when each channel is configured for its installed element
Lube-oil temperature alarmingGenerates temperature alarms and recorder signals for machinery protection
Triple-modular temperature votingCan participate in adjacent-monitor temperature voting arrangements
Read the applicable Bently Nevada installation instructions before work. Verify 3500/60 163179-01 and the installed 3500 Machinery Protection System configuration.
1Verify 163179-01 and its paired temperature I/O module before rack work.
2Isolate sensor and recorder circuits before removing field connections.
3Preserve thermocouple polarity and extension-wire alloy from sensor to rack.
4Record three-wire or four-wire RTD lead assignments before disconnection.
5Configure every channel for the actual sensor type and engineering range.
6Inspect cold-junction and terminal conditions applicable to thermocouple channels.
7For voting service, confirm all adjacent monitor channels and logic paths.
8Apply traceable temperature inputs and prove alarms before returning protection.

Technical notes

Technical notes

Document sensor type, lead configuration, polarity and range for all six channels; after replacement use traceable stimuli to verify indicated temperature, recorder scaling and alarm thresholds.

FAQS

  • Can RTD and thermocouple channels be mixed on 3500/60 163179-01?
    Yes, when each channel is individually configured for its installed sensor type, lead arrangement and engineering range.
  • How should thermocouple polarity be checked for 3500/60 163179-01?
    Trace positive and negative conductors through the terminal path, retain the correct extension-wire alloy and apply a controlled temperature stimulus.
  • What must be recorded for RTD wiring on 3500/60 163179-01?
    Record sensor type, three-wire or four-wire lead identity, terminal positions, range and the as-found resistance or indicated temperature.
  • How is a replacement 3500/60 163179-01 commissioned?
    Restore the six channel definitions, apply traceable temperature inputs and verify indications, recorder signals and alarm thresholds.
  • What should be checked when one 3500/60 163179-01 channel reads incorrectly?
    Check sensor type selection, lead continuity, polarity, terminal condition, configured range and comparison with a traceable calibrator.
  • How does 3500/60 163179-01 support temperature voting?
    Use the documented adjacent-monitor arrangement and verify every channel path plus the configured voting logic before protection release.
  • Can unused inputs on 3500/60 163179-01 be left configured?
    Disable or configure channels according to the approved rack design so open or unused circuits do not create misleading alarms.
  • What records close the maintenance task for 3500/60 163179-01?
    Retain all sensor mappings, as-left configuration, calibration stimulus, recorder scaling, alarm results and final rack diagnostics.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.