Match the complete marking
Include 165855-11 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connection photos. Have your maintenance team compare the offered 165855-11 with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 165855-11
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:165855-11
-
Weight:0.4 kg
-
Tariff Code:8537101190
-
Transducer family:165855 cylinder pressure
-
Pressure range option:11; 0 to 6.8 bar (0 to 100 psia), with armor
-
Measured quantity:Cyclic absolute cylinder pressure
-
Pressure port:7/8-14 UNF; SAE J1926 mating seal
-
Interconnect cable family:146824
-
Monitor family:3500/77M cylinder pressure
-
Supply:18 to 30 Vdc
-
Maximum current:Less than 15 mA
-
Full-scale output:10 +/- 0.3 Vdc
-
Zero output:0.5 +/- 0.1 Vdc
-
Frequency response:0 to 5500 Hz, +/-1 dB
-
Approval suffix:Not present in supplied 165855-11 identity
Information
- Bently Nevada 165855-11 identifies a 165855 cylinder pressure transducer with the 11 armored 0-6.8 bar absolute-pressure range option for reciprocating compressors.
Service access: Isolate and depressurize before removing the sensing head.
Configuration record: Keep unit-specific compensation data with the monitoring channel.
The sensor head mounts at a compressor indicator port or an approved isolation-valve adapter. Its electronics are separated from the wetted end by an integral cable and connect through the 146824 interconnect to a compatible 3500/77M measurement channel.
Use the unit-specific pressure-temperature compensation data supplied with the sensor when configuring the monitor. Protect the diaphragm and confirm the O-ring material, process gas and SAE J1926 sealing arrangement before pressurizing.
-
Bently Nevada 165855-11 technical reference
Original manufacturer Bently Nevada 165855 Cylinder Pressure Transducer, 166815 Rev. M. Family specifications and ordering information. -
Bently Nevada 165855-11 engineering guide
Apter Power installation, interface and fault-isolation guide for the offered complete model.
Platform applications: The applications below describe the complete measuring-channel functions. Verify the target, mounting position and approved channel design before selecting a replacement.
-
Cylinder pressure trend
Measure cyclic absolute pressure for reciprocating-compressor condition analysis. -
Pressure-versus-crank-angle review
Use the compensated channel within the approved machine monitoring configuration. -
Compressor protection
Integrate with the 3500/77M channel and verify alarm settings against the site design. -
Maintenance exchange
Retain sensor-specific compensation values and port-sealing details during replacement.
Use a compatible isolation valve and depressurize before removing the sensor.
Verify sensor, adapter and O-ring compatibility with the actual gas or liquid.
The 7/8-14 body requires the correct mating bore for adequate pressure sealing.
Keep objects away from the sensor diaphragm during transport and installation.
Load the supplied unit-specific temperature points into the approved monitor.
Do not assign a hazardous-area rating from the incomplete 165855-11 code alone.
Alternative Names
Technical notes
Installation relationship: Use a compatible isolation valve and depressurize before removing the sensor.
Measurement boundary: Keep objects away from the sensor diaphragm during transport and installation.
Technical reference: Bently Nevada 165855 Cylinder Pressure Transducer, 166815 Rev. M.
FAQ View All FAQ
-
Why must the O-ring of 165855-11 be checked for process-gas compatibility?An incompatible seal can degrade and cause leakage. Confirm the actual media and select the approved seal material before pressurizing.
-
What happens if 165855-11 is mounted in a bore that does not meet SAE J1926?The thread alone does not establish a pressure seal. Use the specified mating geometry and verify the isolation-valve or adapter arrangement.
-
How should the compensation data for 165855-11 be handled during replacement?Retain the data supplied with the actual sensor and load the corresponding points into the 3500/77M configuration; do not reuse another sensor file.
-
Why is the diaphragm of 165855-11 protected during installation?Contact with tools or foreign objects can damage the sensing surface and corrupt pressure measurement. Use the manufacturer handling procedure.
-
Can the missing approval suffix on 165855-11 be inferred from its 11 range option?No. The 11 segment selects range and armor, while hazardous-area approval is a separate ordering segment. Verify the actual label.
-
What could cause an offset in the signal from 165855-11?Check the zero output, supply, wiring, compensation data and process state before changing monitor calibration or replacing the sensor.
-
How should a pressure line be made safe before servicing 165855-11?Follow the site isolation procedure, depressurize and confirm the indicator port is safe before loosening the sensor or adapter.
-
What evidence should be recorded after commissioning 165855-11?Keep complete marking, sensor compensation data, pressure-port and seal details, monitor channel, zero/full-scale checks and accepted cycle trend.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.