Speak to a sourcing specialist
sales13@apterpower.com

EA1*A

two-wire transmitter input signal conditioner card
In Stock
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Yokogawa EA1*A is a two-wire transmitter input signal conditioner card. Its exact marking, installed interfaces and companion equipment must be verified before replacement or commissioning.
  • Manufacturer part number
    EA1*A
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    11.5cm x 2.4cm x 7.3cm
  • Country of Origin
    Japan
Get a quick price for EA1*A
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.

  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.

  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.

  • Match the complete marking

    Include EA1*A and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered EA1*A reference with the installed equipment and applicable Yokogawa documentation.

Technical specifications for EA1*A

  • Manufacturer:
    Yokogawa
  • Product Category:
    DCS Systems
  • Spare Part Number:
    EA1*A
  • Weight:
    0.01 kg
  • Tariff Code:
    8537101190
  • Card function:
    Two-wire transmitter input
  • Style code:
    *A as supplied
  • Input signal:
    4 to 20 mA DC
  • Input resistance:
    250 Ω
  • Allowable input current:
    40 mA DC
  • Transmitter supply:
    25 to 28 V DC
  • Transmitter current limit:
    25 to 35 mA
  • Output signal:
    1 to 5 V DC, two outputs
  • Output resistance:
    1 Ω maximum
  • Minimum output load:
    2 kΩ
  • Power supply:
    24 V DC ±10 %
  • Maximum current consumption:
    80 mA
  • Accuracy:
    Within ±0.1 % of span
  • Isolation resistance:
    100 MΩ at 500 V DC
  • Withstand voltage:
    1500 V AC input-to-output/power for 1 minute
  • Ambient range:
    0 to 50 °C; 5 to 90 % RH non-condensing

Information

Overview Downloads Applications / Compatibility Product Precautions
  • The complete EA1*A identity establishes the offered hardware. Confirm the installed system, revision and field interfaces before approving the replacement.
Signal role: Powers a two-wire transmitter and converts its 4–20 mA signal to two 1–5 V outputs.
Isolation role: Separates input, outputs and power according to the card specification.
Calibration focus: Verify loop voltage margin, zero, span and both output paths.
EA1*A is a two-wire transmitter input signal conditioner card that supplies the field transmitter, senses 4 to 20 mA and produces two 1 to 5 V outputs for the connected Yokogawa control architecture.

Loop design must include the transmitter minimum operating voltage, cable drop and the card input resistance. The two output paths should be treated as separate acceptance points even though they originate from one input.

Replacement requires the exact style marking, special-nest position, M4 terminal wiring and cable connector to be preserved. Commissioning should record input current, transmitter voltage and both output voltages at low, mid and high points.
Controller platform reference: CENTUM signal conditioning. Verify the interface.
Technical downloads for Yokogawa EA1*A: model-specific technical reference and installation review.
Use the manufacturer source identified in each document to confirm applicability to the installed configuration.
System and supply context: The offered item is Yokogawa EA1*A, condition New, original product. Companion cables, terminal units, adapters and accessories are separate unless itemized in the quotation.

Platform applications: The uses below depend on the installed controller configuration and approved system design.
Prepare Yokogawa EA1*A using the approved machine documentation and site procedure.
Calculate voltage margin

Include transmitter minimum voltage, cable drop and the 250 Ω card input.

Verify terminal polarity

Confirm the A/B/C terminal arrangement from the applicable Yokogawa drawing.

Check 24 V supply

Measure card supply inside the ±10 % range before calibrating the loop.

Prove both outputs

Measure both 1 to 5 V outputs at several input currents.

Inspect nest connector

Check backboard and special-cable contacts for damage or contamination.

Record zero and span

Document low, mid and high input/output results before release.

Alternative Names

EA1*A Yokogawa EA1*A EA1*A

Technical notes

Installation relationship: Use the exact model marking and manufacturer wiring or installation information for the delivered hardware.

System boundary: Verify host equipment, companion interfaces, field wiring and configuration before energizing.

Technical reference: Yokogawa GS 33J60H80-01EN Signal Conditioners.

FAQ View All FAQ

  • How is transmitter voltage margin calculated for EA1*A?
    Subtract cable drop and the 5 V drop across the 250 Ω input at 20 mA from the available transmitter supply, then compare the remainder with the transmitter minimum voltage.
  • How should both outputs of EA1*A be calibrated?
    Inject traceable 4, 12 and 20 mA values and measure both 1 to 5 V outputs independently, recording any deviation.
  • What indicates a field-loop open circuit on EA1*A?
    Check transmitter supply, input current, terminal voltage and both outputs; separate an open field circuit from a card or backboard supply problem.
  • How should polarity be verified on EA1*A?
    Use the Yokogawa terminal drawing for the exact nest and trace field positive/negative conductors before energizing the transmitter.
  • What insulation test is appropriate for EA1*A?
    Remove or isolate connected electronics and use only the manufacturer- and site-approved test voltage; do not megger through live cards or transmitters.
  • How can output disagreement on EA1*A be diagnosed?
    Apply one stable input current and compare both outputs at the card and receiving devices to distinguish card error from downstream load or wiring.
  • What should be recorded before replacing EA1*A?
    Capture style marking, nest position, field terminals, special-cable identity, 24 V supply and low/mid/high loop values.
  • What acceptance result closes work on EA1*A?
    Both outputs must track the verified input within the approved accuracy, the transmitter must retain voltage margin and the control indications must return to the recorded state.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313