Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330425-01-00
-
Weight:0.1 kg
-
Tariff Code:8537101190
-
Sensitivity:25 mV/g ±5%
-
Acceleration range:75 g peak; 10 Hz to 15 kHz
-
Amplitude linearity:±1% to 75 g peak
-
Frequency response, ±3 dB:10 Hz to 15 kHz
-
Frequency response, ±10%:30 Hz to 10 kHz
-
Broadband noise:0.01 g RMS; 10 Hz to 15 kHz
-
Transverse sensitivity:<5% of axial
-
Mounted resonant frequency:>30 kHz
-
Resonant peak amplitude:20 dB maximum
-
Supply voltage:-24 ±0.5 V DC
-
Bias current:2 mA nominal
-
Output bias voltage:-8.5 ±0.5 V DC
-
Grounding:Case isolated
-
Maximum cable length:305 m without signal degradation
-
Operating / storage temperature:-55 to +121 °C
-
Shock survivability:5,000 g peak maximum
-
Humidity:100% condensing, non-submerged
-
Sensor enclosure:IP68 equivalent; cable excluded
-
Maximum use altitude:2,000 m
-
Connector:3-pin MIL-C-5015 receptacle
-
Mounting thread:1/4-28 UNF integral stud
-
Mounting torque:4.1 N·m
-
Case material:316L stainless steel
-
Agency approval option:00 - None
Information
- Bently Nevada 330425-01-00 supports high-frequency casing measurements such as gear-mesh monitoring. A rigid mechanical path from the monitored structure to the sensor is essential for the signal to represent machine vibration.
Electrical interface: -24 ±0.5 V DC supply, three-pin connector
Mounting: 1/4-28 UNF integral stud, 4.1 N·m torque
The three-pin MIL-C-5015 interface requires a -24 ±0.5 V DC supply, with 2 mA nominal bias current and -8.5 ±0.5 V DC output bias. The receiving channel must use the 25 mV/g scale; a channel configured for a 100 mV/g accelerometer would report the wrong acceleration.
The 01 mounting option uses a 1/4-28 UNF integral stud with 4.1 N·m mounting torque. Its electrically isolated, hermetically sealed 316L stainless-steel case supports operation from -55 to +121 °C. The sensor's IP68-equivalent protection excludes the cable assembly, so connector and cable protection remain separate installation considerations.
330425-01-00 Official Datasheet Excerpt
Original manufacturer acceleration, electrical, environmental and mounting data. PDF · 7 pages.330425-01-00 Installation & Verification Guide
Apter Power guide to casing mounting, three-wire connections, negative supply and acceleration-response checks. PDF · 5 pages.
Measurement applications: These uses concern casing acceleration. A measured housing response can represent rotor behavior only when the structure transmits sufficient vibration to the selected point.
Gear-mesh vibration
Observe high-frequency casing acceleration in the 10 Hz to 15 kHz response band, with sufficient mechanical transmission from the gearing.High-amplitude casing acceleration
Use the 75 g peak range with a 25 mV/g monitoring input where the vibration stays within the specified frequency envelope.Bearing-housing measurements
Mount on a rigid housing location aligned with the intended sensing direction, avoiding flexible covers and unsupported brackets.Three-wire monitor channels
Integrate with channels supplying the specified negative voltage and reading acceleration at 25 mV/g; verify wiring and input setup.
Verify -24 ±0.5 V DC. Do not substitute the positive constant-current circuit used by a different accelerometer family.
Check the input sensitivity before accepting acceleration values or enabling channel alarms.
Read the serial prefix and retain the specified mounting base for older non-G units.
Prepare the contact surface and apply 4.1 N·m without loading the electrical connector.
Sensor enclosure protection does not establish cable or connector protection, or hazardous-area approval.
Check dynamic response in the required band; vibration above 15 kHz can reduce usable acceleration range.
Alternative Names
Technical notes
Mounting relationship: The sensor must receive vibration through the bearing housing or machine casing. Check surface preparation, stud torque and the serial-dependent mounting-base requirement.
Signal conditioning: Use the specified negative supply and 25 mV/g scale. The wider ±3 dB frequency band and narrower ±10% band are different acceptance criteria.
Environmental boundary: The hermetic sensor rating excludes the interconnect cable. Use a protected installation and appropriate cable routing.
Technical reference: Bently Nevada 330400 and 330425 Accelerometer Acceleration Transducers, 141638 Rev. AB.
FAQ View All FAQ
-
Why must a 100 mV/g input setting be changed when installing 330425-01-00?This sensor produces 25 mV/g, one quarter of a 100 mV/g sensor output for the same acceleration. Configure the input for 25 mV/g; otherwise the indicated acceleration will be scaled incorrectly.
-
Can 330425-01-00 retain its 75 g peak range above 15 kHz?The 75 g peak rating applies within 10 Hz to 15 kHz. Higher-frequency vibration, especially near the sensor resonance, significantly reduces that usable range. The mounted resonance above 30 kHz is not an extension of the calibrated band.
-
Which response tolerance applies when using 330425-01-00 between 30 Hz and 10 kHz?The response tolerance is ±10% over 30 Hz to 10 kHz. The wider 10 Hz to 15 kHz band uses a ±3 dB tolerance. Use the appropriate band when judging an amplitude measurement.
-
How does the serial-number prefix affect mounting-base selection for 330425-01-00?Sensors with a G serial prefix have lower base-strain sensitivity. For earlier units without that prefix, use the specified mounting base to reduce strain-related output. Check the actual serial number before retaining or removing an existing adapter.
-
What does case isolation mean for the three-wire connection of 330425-01-00?The sensor case is isolated from the electrical circuit. Use the correct supply, signal and common connections through the three-pin receptacle and the approved cable wiring. Do not use the casing as a substitute for the electrical return conductor.
-
Does the enclosure rating of 330425-01-00 also protect its interconnect cable?No. The IP68-equivalent rating applies to the sensor only. Choose and protect the cable and mating connector for the environment; the humidity condition is condensing and non-submerged.
-
What mounting torque should be applied to the integral stud of 330425-01-00?Apply 4.1 N·m to the properly prepared mounting interface. Maintain a rigid, clean contact with the machine surface. Incorrect mounting can reduce response or introduce signals unrelated to the actual casing vibration.
-
Which DC readings distinguish a correctly powered 330425-01-00 channel?Check the -24 ±0.5 V DC supply and -8.5 ±0.5 V DC output bias; nominal bias current is 2 mA. Follow these electrical checks with a controlled acceleration-response test, because a normal bias alone does not prove mechanical coupling.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.